Transducer arrays for rapid data acquisition of ultrasonic diffraction tomography

被引:0
作者
Ohmaru, M
Yokoyama, T
Mizutani, K
Nagai, K
机构
来源
JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS | 1996年 / 35卷 / 5B期
关键词
diffraction tomography; transducer array; electronic scanning; resolution; spline interpolation;
D O I
10.1143/JJAP.35.3139
中图分类号
O59 [应用物理学];
学科分类号
摘要
We describe results of experiments and numerical simulations on transducer arrays and the apparatus used to drive them. Thses devices were fabricated for rapid data acquisition in ultrasonic diffraction tomography. The arrays are made by evaporation coating on piezoelectric ceramic substrates and the interval between the elements is using by the theory of acoustic holography. One of two similar arrays is used as the transmitter and the other is used as the receiver. In the experiment on a thin wire object it is proved that the interval is sufficient and that spline interpolation is effective, although the problem remains that the performance of each array element is different. The numerical simulation for the thick object shows, however, that the resolution of the reconstructed image is degraded. Because the element interval is inappropriate in this case.
引用
收藏
页码:3139 / 3143
页数:5
相关论文
共 3 条
[1]  
TABEI M, 1995, US9412 IEICE, P17
[2]  
Yokoyama T., 1995, Journal of the Acoustical Society of Japan, V51, P366
[3]   3-DIMENSIONAL IMAGE-RECONSTRUCTION OF DIFFRACTION TOMOGRAPHY FROM DATA COLLECTED WITH COMPOUND SCANNED PAIR OF TRANSDUCERS [J].
YOKOYAMA, T ;
MIZUTANI, K ;
NAGAI, K .