Second-generation Highly Cross-linked X3™ Polyethylene Wear: A Preliminary Radiostereometric Analysis Study

被引:44
作者
Campbell, David G. [1 ]
Field, John R. [2 ]
Callary, Stuart A. [3 ,4 ]
机构
[1] Wakefield Orthopaed Clin, Adelaide, SA 5000, Australia
[2] Flinders Univ S Australia, CORe Comparat Orthopaed Res Surg Facil, Adelaide, SA, Australia
[3] Univ Adelaide, Adelaide, SA, Australia
[4] Royal Adelaide Hosp, Dept Orthopaed & Trauma, Adelaide, SA 5000, Australia
关键词
TOTAL HIP-ARTHROPLASTY; MOLECULAR-WEIGHT POLYETHYLENE; FEMORAL-HEAD-PENETRATION; IN-VIVO WEAR; MECHANICAL-PROPERTIES; SURFACE CRACKING; CONTROLLED-TRIAL; FOLLOW-UP; OSTEOLYSIS; RATES;
D O I
10.1007/s11999-010-1259-y
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
First-generation highly cross-linked polyethylene liners have reduced the incidence of wear particle-induced osteolysis. However, failed acetabular liners have shown evidence of surface cracking, mechanical failure, and oxidative damage. This has led to the development of second-generation highly cross-linked polyethylene, which has improved wear and mechanical properties and resistance to oxidation in vitro. Owing to its recent introduction, there are no publications describing its clinical performance. We assessed early clinical wear of a second-generation highly cross-linked polyethylene liner and compared its clinical performance with the published results of hip simulator tests and with first-generation highly cross-linked polyethylene annealed liners. Twenty-one patients were enrolled in a prospective cohort study. Clinical outcome and femoral head penetration were measured for 19 patients at 6 months and 1 and 2 years postoperatively. The median proximal head penetration was 0.009 mm and 0.024 mm at 1 and 2 years, respectively. The median two-dimensional (2-D) head penetration was 0.083 mm and 0.060 mm at 1 and 2 years, respectively. The median proximal wear rate between 1 and 2 years was 0.015 mm/year. The wear rate calculated was similar to the in vitro wear rate reported for this material; however, it was less than the detection threshold for this technique. Although longer followup is required for wear to reach a clinically quantifiable level, this low level of wear is encouraging for the future clinical performance of this material. Level IV, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.
引用
收藏
页码:2704 / 2709
页数:6
相关论文
共 52 条
[1]  
Altman DG, 1990, PRACTICAL STAT MED R, DOI DOI 10.1201/9780429258589
[2]  
[Anonymous], ANN REP AOA
[3]  
Avery J., 2004, Quality of Life in South Australia as Measured by the SF12 Health Status Questionnaire
[4]   RSA wear measurements with or without markers in total hip arthroplasty [J].
Börlin, N ;
Röhrl, SM ;
Bragdon, CR .
JOURNAL OF BIOMECHANICS, 2006, 39 (09) :1641-1650
[5]   Wear and surface cracking in early retrieved highly cross-linked polyethylene acetabular liners [J].
Bradford, L ;
Baker, DA ;
Graham, J ;
Chawan, A ;
Ries, MD ;
Pruitt, LA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2004, 86A (06) :1271-1282
[6]   Standing versus supine radiographs in RSA evaluation of femoral head penetration [J].
Bragdon, Charles R. ;
Thanner, Jonas ;
Greene, Meridith E. ;
Malchau, Henrik ;
Digas, Georgios ;
Harris, William H. ;
Karrholm, Johan .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2006, (448) :46-51
[7]   Steady-state penetration rates of electron beam-irradiated, highly cross-linked polyethylene at an average 45-month follow-up [J].
Bragdon, Charles R. ;
Barrett, Susan ;
Martell, John M. ;
Greene, Meridith E. ;
Malchau, Henrik ;
Harris, William H. .
JOURNAL OF ARTHROPLASTY, 2006, 21 (07) :935-943
[8]   Experimental assessment of precision and accuracy of radio stereometric analysis for the determination of polyethylene wear in a total hip replacement model [J].
Bragdon, CR ;
Malchau, H ;
Yuan, XH ;
Perinchief, R ;
Kärrholm, J ;
Börlin, N ;
Estok, DM ;
Harris, WH .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2002, 20 (04) :688-695
[9]   Wear of a highly cross-linked polyethylene liner: a preliminary RSA study [J].
Campbell, David ;
Mercer, Graham ;
Nilsson, Kjell-Gunnar ;
Wells, Vanessa ;
Field, John R. ;
Callary, Stuart A. .
EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2010, 20 (01) :23-27
[10]   Reasons for revision hip surgery - A retrospective review [J].
Clohisy, JC ;
Calvert, G ;
Tull, F ;
McDonald, D ;
Maloney, WJ .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (429) :188-192