Do surgeons and surgical facilities disturb the clean air distribution close to a surgical patient in an orthopedic operating room with laminar airflow?

被引:41
作者
Cao, Guangyu [1 ]
Storas, Madeleine C. A. [1 ]
Aganovic, Amar [1 ]
Stenstad, Liv-Lnger [2 ]
Skogas, Jan Gunnar [2 ]
机构
[1] Norwegian Univ Sci & Technol, Dept Energy & Proc Engn, Kolbjorn Hejes Vei 1b, N-7491 Trondheim, Norway
[2] St Olavs Hosp, Trondheim, Norway
关键词
Surgical site infection; Thermal plume; Laminar airflow; Operating room; Air velocity; Airflow distribution; Pperating microenvironment; AIRBORNE CONTAMINATION; SITE INFECTION; VENTILATION; PERFORMANCE; VELOCITY; SYSTEM; IMPACT; HIP;
D O I
10.1016/j.ajic.2018.03.019
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Background: Airflow distribution in the operating room plays an important role in ensuring a clean operating microenvironment and preventing surgical site infections (SSIs) caused by airborne contaminations. The objective of this study was to characterize the airflow distribution in proximity to a patient in an orthopedic operating room. Methods: Experimental measurements were conducted in a real operating room at St. Olav's Hospital, Norway, with a laminar airflow system. Omnidirectional anemometers were used to investigate the air distribution in the operating zone, and 4 different cases were examined with a real person and a thermal manikin. Results: This study showed that the downward airflow from the laminar airflow system varies in each case with different surgical arrangement, such as the position of the operating lamp. The results indicate that the interaction of thermal plumes from a patient and the downward laminar airflowmay dominate the operating microenvironment. Conclusions: The airflow distribution in proximity to a patient is influenced by both the surgical facility and the presence of medical staff. A thermal manikin may be an economical and practical way to study the interaction of thermal plumes and downward laminar airflow. The provision of higher clean airflow rate in the operating microenvironment may be an effective way to prevent the development of SSIs caused by indoor airborne contamination. (C) 2018 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:1115 / 1122
页数:8
相关论文
共 12 条
  • [1] Laminar airflow and mixing ventilation: Which is better for operating room airflow distribution near an orthopedic surgical patient?
    Cao, Guangyu
    Nilssen, Anders M.
    Cheng, Zhu
    Stenstad, Liv-Inger
    Radtke, Andreas
    Skogas, Jan Gunnar
    AMERICAN JOURNAL OF INFECTION CONTROL, 2019, 47 (07) : 737 - 743
  • [2] Surgical clothing systems in laminar airflow operating room: a numerical assessment
    Sadrizadeh, Sasan
    Holmberg, Sture
    JOURNAL OF INFECTION AND PUBLIC HEALTH, 2014, 7 (06) : 508 - 516
  • [3] Impact of surgical lights on the velocity distribution and airborne contamination level in an operating room with laminar airflow system
    Aganovic, Amar
    Cao, Guangyu
    Stenstad, Liv-Inger
    Skogas, Jan Gunnar
    BUILDING AND ENVIRONMENT, 2017, 126 : 42 - 53
  • [4] The application value of operating room ventilation with laminar airflow for surgical site infection A protocol for a systematic review and meta-analysis
    Liu, Yuan-Yuan
    Shi, Ling-Yun
    Duan, Yong-Mei
    Li, Xiu-Mei
    MEDICINE, 2021, 100 (32) : E26814
  • [5] Effect of air exhaust location on surgical site particle distribution in an operating room
    Agirman, Aleyna
    Cetin, Yunus Emre
    Avci, Mete
    Aydin, Orhan
    BUILDING SIMULATION, 2020, 13 (05) : 979 - 988
  • [6] Laminar airflow ventilation systems in orthopaedic operating room do not prevent surgical site infections: a systematic review and meta-analysis
    Ouyang, Xueqian
    Wang, Qiaolin
    Li, Xiaohua
    Zhang, Ting
    Rastogi, Sanjay
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2023, 18 (01)
  • [7] Improvement of operating room air quality and sustained reduction of surgical site infections in an orthopedic specialty hospital
    Mullen, Anildaliz N.
    Wieser, Eric
    AMERICAN JOURNAL OF INFECTION CONTROL, 2024, 52 (02) : 183 - 190
  • [8] Laminar airflow ventilation systems in orthopaedic operating room do not prevent surgical site infections: a systematic review and meta-analysis
    Xueqian Ouyang
    Qiaolin Wang
    Xiaohua Li
    Ting Zhang
    Sanjay Rastogi
    Journal of Orthopaedic Surgery and Research, 18
  • [9] Effect of air exhaust location on surgical site particle distribution in an operating room
    Aleyna Agirman
    Yunus Emre Cetin
    Mete Avci
    Orhan Aydin
    Building Simulation, 2020, 13 : 979 - 988
  • [10] Three distinct surgical clothing systems in a turbulent mixing operating room equipped with mobile ultraclean laminar airflow screen: A numerical evaluation
    Sadrizadeh, Sasan
    Holmberg, Sture
    Nielsen, Peter V.
    SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2016, 22 (03) : 337 - 345