Cuspal movement and microleakage in premolar teeth restored with a packable composite cured in bulk or in increments

被引:121
作者
Abbas, G
Fleming, GJP
Harrington, E
Shortall, ACC
Burke, FJT
机构
[1] Univ Birmingham, Primary Dent Care Res Unit, Sch Dent, Birmingham B4 6NN, W Midlands, England
[2] Univ Birmingham, Biomat Unit, Sch Dent, Birmingham B4 6NN, W Midlands, England
关键词
cuspal movement; gingival microleakage; packable composite; curing;
D O I
10.1016/S0300-5712(02)00121-5
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction. The aim of this study was to investigate the effect of two novel curing systems (a plasma arc light, and a 'turbo-boosted' conventional curing light) on cuspal movement and gingival microleakage of 'packable' resin-based composite (RBC) restorations placed in extracted maxillary premolar teeth. Materials and methods. Forty sound extracted upper premolar teeth were subjected to standardised preparation of a large mesio-occlusal-distal cavity before restoration with a RBC. Four curing regimens were used. Either the RBC was placed in bulk and light-cured in one increment using (a) the plasma arc light; (b) the 'turbo-boosted' curing light, or the RBC was placed in eight increments using (c) the plasma arc Light; (d) the 'turbo-boosted' curing light. A deflection measuring gauge allowed a measurement of cuspal deflection at each stage of polymerisation. Restored teeth were thermocycled before immersion in a 0.2% basic fuchsin dye for 24 h. After sagittal sectioning of the restored teeth in a mesio-distal plane, the sectioned restorations were examined to assess cervical microleakage. Results. Cuspal deflection measurements were significantly increased when the 'turbo-boosted' halogen curing light was compared with the plasma arc light. Total mean cuspal deflection measurements obtained with incremental cure were significantly increased compared with bulk cure for both light sources. Gingival microleakage for bulk restored teeth was significantly increased compared with teeth restored incrementally. Incremental restoration with the plasma arc light had significantly increased gingival microleakage compared with the 'turbo-boosted' halogen curing light. Conclusions. The packable composite tested could not be cured adequately to a depth of 5 mm with the plasma arc light within the specified irradiation time. Under the test conditions of the current investigation, bulk curing only appeared to be practical with the high intensity halogen light (40 s activation). Incremental. build-up and polymerisation optimised marginal seat for the high intensity halogen light but led to greater cuspal deflection. (C) 2003 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:437 / 444
页数:8
相关论文
共 28 条
[1]  
Ben-Amar A, 1989, Quintessence Int, V20, P903
[2]  
Beznos C, 2001, OPER DENT, V26, P60
[3]   THE DEFORMATION OF CUSPS BY BONDED POSTERIOR COMPOSITE RESTORATIONS - AN INVITRO STUDY [J].
CAUSTON, BE ;
MILLER, B ;
SEFTON, J .
BRITISH DENTAL JOURNAL, 1985, 159 (12) :397-400
[4]   Curing restorative resin: A significant controversy [J].
Christensen, GJ .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 2000, 131 (07) :1067-1069
[5]  
Coli P, 1993, Quintessence Int, V24, P583
[7]  
ELMOWAFY OM, 1994, J DENT, V22, P33
[8]   Comparison between a plasma arc light source and conventional halogen curing units regarding flexural strength, modulus, and hardness of photoactivated resin composites. [J].
Hofmann N. ;
Hugo B. ;
Schubert K. ;
Klaiber B. .
Clinical Oral Investigations, 2000, 4 (3) :140-147
[9]  
Holan G, 1989, Am J Dent, V2, P274
[10]   Comparison of methods for measuring cuspal deformation in teeth [J].
Jantarat, J ;
Panitvisai, P ;
Palamara, JEA ;
Messer, HH .
JOURNAL OF DENTISTRY, 2001, 29 (01) :75-82