Behaviour of a planar Langmuir probe in a laser ablation plasma

被引:21
|
作者
Doggett, B [1 ]
Budtz-Joergensen, C
Lunney, JG
Sheerin, P
Turner, MM
机构
[1] Trinity Coll Dublin, Dept Phys, Dublin, Ireland
[2] Dublin City Univ, Sch Phys Sci, Dublin 9, Ireland
[3] Dublin City Univ, Natl Ctr Plasma Sci & Technol, Dublin 9, Ireland
关键词
laser ablation plasma; excimer laser; plasma immersion ion implantation;
D O I
10.1016/j.apsusc.2005.01.035
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
We have investigated some aspects of the behaviour of planar Langmuir probes in the supersonic plasma flow produced by laser ablation of solid materials in vacuum. The ablation was done using a 26 ns, 248 nm excimer laser, irradiating a silver target at 1 J cm(-2). We have compared the behaviour of the probe when it is orientated perpendicular and parallel to the plasma flow. In particular, we have shown that it is possible to adapt an analytical model, developed for plasma immersion ion implantation, to quantitatively describe the variation of the ion current with probe bias for the case when the plasma flow is along the probe surface. The electron temperature was also measured. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:134 / 138
页数:5
相关论文
共 50 条
  • [31] Laser photo-detachment combined with Langmuir probe in magnetized electronegative plasma: how the probe size affects the plasma dynamic?
    Oudini, N.
    Bendib, A.
    Agnello, R.
    Furno, I
    Taccogna, F.
    PLASMA SOURCES SCIENCE & TECHNOLOGY, 2021, 30 (11):
  • [32] Comparison of Langmuir probe and laser Thomson scattering for plasma density and electron temperature measurements in HiPIMS plasma
    Ryan, Peter J.
    Bradley, James W.
    Bowden, Mark D.
    PHYSICS OF PLASMAS, 2019, 26 (04)
  • [33] Diagnostics of tin droplet-based laser produced plasma by triple Langmuir probe
    Chen, Zegong
    Zuo, Duluo
    Wang, Xinbing
    VACUUM, 2024, 230
  • [34] Two-dimensional fluid simulation and Langmuir probe measurement of a planar inductively coupled oxygen plasma
    Department of Physics, Dong-A University, Pusan 604-714, Korea, Republic of
    Jpn J Appl Phys Part 1 Regul Pap Short Note Rev Pap, 12 A (6890-6895):
  • [35] LANGMUIR PROBE MEASUREMENTS OF AXIAL VARIATION OF PLASMA PARAMETERS IN 27.1 MHZ RF OXYGEN PLANAR DISCHARGES
    SABADIL, H
    KLAGGE, S
    KAMMEYER, M
    PLASMA CHEMISTRY AND PLASMA PROCESSING, 1988, 8 (04) : 425 - 444
  • [36] Two-dimensional fluid simulation and Langmuir probe measurement of a planar inductively coupled oxygen plasma
    Yoon, HJ
    Chung, TH
    Seo, DC
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS, 1999, 38 (12A): : 6890 - 6895
  • [37] Comparative measurement of plasma potential with tube probe and Langmuir probe
    Li, Jian-quan
    Lu, Wen-qi
    Xu, Jun
    Gao, Fei
    Wang, You-nian
    AIP ADVANCES, 2018, 8 (11):
  • [38] Estimation of Al2O3 critical temperature using a Langmuir probe in laser ablation
    K. Yahiaoui
    S. Abdelli-Messaci
    S. Messaoud Aberkane
    A. Kellou
    Applied Physics A, 2016, 122
  • [39] Estimation of Al2O3 critical temperature using a Langmuir probe in laser ablation
    Yahiaoui, K.
    Abdelli-Messaci, S.
    Aberkane, S. Messaoud
    Kellou, A.
    APPLIED PHYSICS A-MATERIALS SCIENCE & PROCESSING, 2016, 122 (11):
  • [40] Langmuir Probe Measurements of an Expanding Argon Plasma
    Cao Xiaogang
    Xia Yuxi
    Chen Bingzhou
    Tian Shuping
    Wang Chunling
    Yang Dangxiao
    Xue Xiaoyan
    Zhang Weiwei
    Wang Jianqiang
    Gou Fujun
    Zhu Zichuan
    Ou Wei
    Chen Shunli
    PLASMA SCIENCE & TECHNOLOGY, 2015, 17 (01) : 20 - 24