Exact monitoring of aortic diameters in Marfan patients without gadolinium contrast: intraindividual comparison of 2D SSFP imaging with 3D CE-MRA and echocardiography

被引:28
|
作者
Veldhoen, Simon [1 ,2 ]
Behzadi, Cyrus [2 ]
Derlin, Thorsten [2 ]
Rybczinsky, Meike [3 ]
von Kodolitsch, Yskert [3 ]
Sheikhzadeh, Sara [3 ]
Henes, Frank Oliver [2 ]
Bley, Thorsten Alexander [1 ]
Adam, Gerhard [2 ]
Bannas, Peter [2 ]
机构
[1] Univ Med Ctr Wurzburg, Dept Diagnost & Intervent Radiol, Bavaria, Germany
[2] Univ Med Ctr Hamburg Eppendorf, Dept Diagnost & Intervent Radiol, D-20246 Hamburg, Germany
[3] Univ Med Ctr Hamburg Eppendorf, Dept Gen & Intervent Cardiol, D-20246 Hamburg, Germany
关键词
Marfan syndrome; Magnetic resonance angiography; Contrast agents; Sinus Valsalva; Aortic aneurysm; NEPHROGENIC SYSTEMIC FIBROSIS; LIFE EXPECTANCY; ROOT DIMENSIONS; THORACIC AORTA; ANGIOGRAPHY; AGENTS; REPLACEMENT; ACCURACY; HEART;
D O I
10.1007/s00330-014-3457-6
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To assess whether ECG-gated non-contrast 2D steady-state free precession (SSFP) imaging allows for exact monitoring of aortic diameters in Marfan syndrome (MFS) patients using non-ECG-gated contrast-enhanced 3D magnetic resonance angiography (CE-MRA) and echocardiography for intraindividual comparison. Methods Non-ECG-gated CE-MRA and ECG-gated non-contrast SSFP at 1.5 T were prospectively performed in 50 patients. Two readers measured aortic diameters on para-sagittal images identically aligned with the aortic arch at the sinuses of Valsalva, sinotubular junction, ascending/descending aorta and aortic arch. Image quality was assessed on a three-point scale. Aortic root diameters acquired by echocardiography were used as reference. Results Intra-and interobserver variances were smaller for SSFP at the sinuses of Valsalva (p=0.002; p=0.002) and sinotubular junction (p=0.014; p=0.043). Image quality was better in SSFP than in CE-MRA at the sinuses of Valsalva (p<0.0001), sinotubular junction (p<0.0001) and ascending aorta (p=0.02). CE-MRA yielded higher diameters than SSFP at the sinuses of Valsalva (mean bias, 2.5 mm; p<0.0001), and comparison with echocardiography confirmed a higher bias for CE-MRA (7.2 +/- 3.4 mm vs. SSFP, 4.7 +/- 2.6 mm). Conclusion ECG-gated non-contrast 2D SSFP imaging provides superior image quality with higher validity compared to non-ECG-gated contrast-enhanced 3D imaging. Since CE-MRA requires contrast agents with potential adverse effects, non-contrast SSFP imaging is an appropriate alternative for exact and riskless aortic monitoring of MFS patients.
引用
收藏
页码:872 / 882
页数:11
相关论文
共 23 条
  • [1] Exact monitoring of aortic diameters in Marfan patients without gadolinium contrast: intraindividual comparison of 2D SSFP imaging with 3D CE-MRA and echocardiography
    Simon Veldhoen
    Cyrus Behzadi
    Thorsten Derlin
    Meike Rybczinsky
    Yskert von Kodolitsch
    Sara Sheikhzadeh
    Frank Oliver Henes
    Thorsten Alexander Bley
    Gerhard Adam
    Peter Bannas
    European Radiology, 2015, 25 : 872 - 882
  • [2] Assessment of aortic diameter in Marfan patients: intraindividual comparison of 3D-Dixon and 2D-SSFP magnetic resonance imaging
    Wright, Felicia
    Warncke, Malte
    Sinn, Martin
    Ristow, Inka
    Lenz, Alexander
    Riedel, Christoph
    Schoennagel, Bjoern P.
    Zhang, Shuo
    Kaul, Michael G.
    Adam, Gerhard
    von Kodolitsch, Yskert
    Sehner, Susanne
    Bannas, Peter
    EUROPEAN RADIOLOGY, 2023, 33 (03) : 1687 - 1697
  • [3] Assessment of aortic diameter in Marfan patients: intraindividual comparison of 3D-Dixon and 2D-SSFP magnetic resonance imaging
    Felicia Wright
    Malte Warncke
    Martin Sinn
    Inka Ristow
    Alexander Lenz
    Christoph Riedel
    Bjoern P. Schoennagel
    Shuo Zhang
    Michael G. Kaul
    Gerhard Adam
    Yskert von Kodolitsch
    Susanne Sehner
    Peter Bannas
    European Radiology, 2023, 33 : 1687 - 1697
  • [4] Intraindividual comparison of 1.5 T and 3 T non-contrast MR angiography for monitoring of aortic root diameters in Marfan patients
    Avanesov, Maxim
    Weinrich, Julius Matthias
    Sinn, Martin
    Lenz, Alexander
    von Duering, Felicia
    Salamon, Johannes
    Henes, Frank-Oliver
    Schoennagel, Bjoern Peter
    Adam, Gerhard
    von Kodolitsch, Yskert
    Bannas, Peter
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2021, 337 : 119 - 126
  • [5] Comparison of a novel Compressed SENSE accelerated 3D modified relaxation-enhanced angiography without contrast and triggering with CE-MRA in imaging of the thoracic aorta
    Pennig, Lenhard
    Wagner, Anton
    Weiss, Kilian
    Lennartz, Simon
    Huntgeburth, Michael
    Hickethier, Tilman
    Maintz, David
    Naehle, Claas Philip
    Bunck, Alexander Christian
    Doerner, Jonas
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2021, 37 (01) : 315 - 329
  • [6] Thoracic aorta diameters in Marfan patients: Intraindividual comparison of 3D modified relaxation-enhanced angiography without contrast and triggering (REACT) with transthoracic echocardiography
    Gietzen, Carsten
    Pennig, Lenhard
    von Stein, Jennifer
    Guthoff, Henning
    Weiss, Kilian
    Gertz, Roman
    Thuerbach, Iris
    Bunck, Alexander C.
    Maintz, David
    Baldus, Stephan
    Ten Freyhaus, Henrik
    Hohmann, Christopher
    von Stein, Philipp
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2023, 390
  • [7] Measuring Aortic Diameter With Different MR Techniques: Comparison of Three-Dimensional (3D) Navigated Steady-State Free-Precession (SSFP), 3D Contrast-Enhanced Magnetic Resonance Angiography (CE-MRA), 2D T2 Black Blood, and 2D Cine SSFP
    Potthast, Silke
    Mitsumori, Lee
    Stanescu, Luana A.
    Richardson, Michael L.
    Branch, Kelley
    Dubinsky, Theodore J.
    Maki, Jeffrey H.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2010, 31 (01) : 177 - 184
  • [8] Comparison of great artery dimensions in 3-D dual-phase SSFP, compared with 3D CE-MRA and phase-contrast imaging (magnitude image)
    Aimin Sun
    Srinivas Ananth Narayan
    Gerald F Greil
    Tarique Hussain
    Kuberan Pushparajah
    Aaron Bell
    Sujeev Mathur
    Reza Razavi
    Journal of Cardiovascular Magnetic Resonance, 17 (Suppl 1)
  • [9] Comparison of 3D TOF-MRA and 3D CE-MRA at 3T for imaging of intracranial aneurysms
    Cirillo, Mario
    Scomazzoni, Francesco
    Cirillo, Luigi
    Cadioli, Marcello
    Simionato, Franco
    Iadanza, Antonella
    Kirchin, Miles
    Righi, Claudio
    Anzalone, Nicoletta
    EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (12) : E853 - E859
  • [10] Comparison of a novel Compressed SENSE accelerated 3D modified relaxation-enhanced angiography without contrast and triggering with CE-MRA in imaging of the thoracic aorta
    Lenhard Pennig
    Anton Wagner
    Kilian Weiss
    Simon Lennartz
    Michael Huntgeburth
    Tilman Hickethier
    David Maintz
    Claas Philip Naehle
    Alexander Christian Bunck
    Jonas Doerner
    The International Journal of Cardiovascular Imaging, 2021, 37 : 315 - 329