Effect of selective laser trabeculoplasty on corneal biomechanics

被引:15
作者
Pillunat, Karin R. [1 ]
Spoerl, Eberhard [1 ]
Terai, Naim [1 ]
Pillunat, Lutz E. [1 ]
机构
[1] Tech Univ Dresden, Univ Hosp Carl Gustav Carus, Dept Ophthalmol, Fetscherstr 74, D-01307 Dresden, Germany
关键词
corneal hysteresis; corneal resistance factor; intraocular pressure; ocular response analyzer; open-angle glaucoma; selective laser trabeculoplasty; OPEN-ANGLE GLAUCOMA; OCULAR RESPONSE ANALYZER; IN-SITU KERATOMILEUSIS; TRABECULAR MESHWORK; MYOPIC REGRESSION; HYSTERESIS; HYPERTENSION; THERAPY; VIVO; EYES;
D O I
10.1111/aos.12947
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PurposeTo evaluate the effect of selective laser trabeculoplasty (SLT) on ocular biomechanics as measured with the ocular response analyzer (ORA, AMETEK Inc. and Reichert Inc.). MethodsIn a prospective case series, 52 eyes of 52 patients (aged 66.69.6years) with insufficient intraocular pressure (IOP) control despite maximum tolerated medical therapy underwent SLT (Solo SLT, Ellex Inc.) for further IOP reduction. Goldmann-correlated IOP (IOPg), corneal-compensated IOP (IOPcc), corneal hysteresis (CH) and the corneal resistance factor (CRF) were measured with the ORA prior to and at least 4weeks following SLT. ResultsIOPg decreased statistically significantly from 18.0 +/- 6.4 to 14.8 +/- 3.8mmHg and IOPcc from 20.2 +/- 6.5 to 16.7 +/- 3.4mmHg (p<0.001). CH increased from 8.53 +/- 2.03 to 9.12 +/- 1.83mmHg (p=0.028) and CRF decreased from 9.58 +/- 2.18 to 9.1 +/- 2.1mmHg (p=0.037), which was statistically significant. Correcting the CH and CRF data for the influence of IOP reduction with a covariance analysis, however, resulted in an unchanged CH (IOPg adjusted: p=0.318; IOPcc adjusted: p=0.468) and CRF (IOPg adjusted: p=0.320; IOPcc adjusted: p=0.464) after SLT. ConclusionSelective laser trabeculoplasty does not change corneal biomechanical properties as measured with the ORA in already pretreated patients with glaucoma. The measured increase in CH and decrease in CRF can be solely explained by IOP reduction.
引用
收藏
页码:E501 / E504
页数:4
相关论文
共 24 条
[1]   Corneal hysteresis measured with the Ocular Response Analyzer® in normal and glaucomatous eyes [J].
Abitbol, Olivia ;
Bouden, Jihene ;
Doan, Serge ;
Hoang-Xuan, Thanh ;
Gatinel, Damien .
ACTA OPHTHALMOLOGICA, 2010, 88 (01) :116-119
[2]   The relationship between corneal hysteresis and the magnitude of intraocular pressure reduction with topical prostaglandin therapy [J].
Agarwal, Daniel R. ;
Ehrlich, Joshua R. ;
Shimmyo, Mitsugu ;
Radcliffe, Nathan M. .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2012, 96 (02) :254-257
[3]   Comparison of factors that influence the measurement of corneal hysteresis in vivo and in vitro [J].
Alhamad, Tariq A. ;
Meek, Keith M. .
ACTA OPHTHALMOLOGICA, 2011, 89 (05) :E443-E450
[4]   A new insight into the cellular regulation of aqueous outflow: how trabecular meshwork endothelial cells drive a mechanism that regulates the permeability of Schlemm's canal endothelial cells [J].
Alvarado, JA ;
Alvarado, RG ;
Yeh, RF ;
Franse-Carman, L ;
Marcellino, GR ;
Brownstein, MJ .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2005, 89 (11) :1500-1505
[5]   A case of keratoconus progression associated with the use of topical latanoprost [J].
Amano, Shiro ;
Nakai, Yoshiyuki ;
Ko, Akiko ;
Inoue, Kenji ;
Wakakura, Masato .
JAPANESE JOURNAL OF OPHTHALMOLOGY, 2008, 52 (04) :334-336
[6]   Inflammation assessment after selective laser trabeculoplasty (SLT) treatment [J].
Ayala, Marcelo ;
Hogbech, Irene Landau ;
Chen, Enping .
ACTA OPHTHALMOLOGICA, 2011, 89 (04) :E306-E309
[7]  
Bradley JMB, 2000, INVEST OPHTH VIS SCI, V41, P422
[8]   Changes in central corneal thickness over time - The Ocular Hypertension Treatment Study [J].
Brandt, James D. ;
Gordon, Mae O. ;
Beiser, Julia A. ;
Lin, Shan C. ;
Alexander, Monica Y. ;
Kass, Michael A. .
OPHTHALMOLOGY, 2008, 115 (09) :1550-1556
[9]   The collagen matrix of the human trabecular meshwork is an extension of the novel pre-Descemet's layer (Dua's layer) [J].
Dua, Harminder S. ;
Faraj, Lana A. ;
Branch, Matthew J. ;
Yeung, Aaron M. ;
Elalfy, Mohamed S. ;
Said, Dalia G. ;
Gray, Trevor ;
Lowe, James .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2014, 98 (05) :691-697
[10]   Long-term follow-up of selective laser trabeculoplasty in primary open-angle glaucoma [J].
Gracner, T. ;
Falez, M. ;
Gracner, B. ;
Pahor, D. .
KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2006, 223 (09) :743-747