A real-time IGRT method using a Kalman filter framework to extract 3D positions from 2D projections

被引:5
作者
Nguyen, Doan Trang [1 ,2 ]
Keall, Paul [1 ]
Booth, Jeremy [3 ,4 ]
Shieh, Chun-Chien [2 ]
Poulsen, Per [5 ]
O'Brien, Ricky [2 ]
机构
[1] Univ Technol Sydney, Sch Biomed Engn, Sydney, NSW, Australia
[2] Univ Sydney, ACRF ImageX Inst, Sydney, NSW, Australia
[3] Royal North Shore Hosp, Northern Sydney Canc Care Ctr, St Leonards, NSW, Australia
[4] Univ Sydney, Sch Phys, Sydney, NSW, Australia
[5] Aarhus Univ Hosp, Dept Radiat Oncol, Aarthus, Denmark
关键词
prostate cancer; IGRT; Adaptive filter; intrafraction motion; TRACKING SYSTEM; TUMOR-TRACKING; FIDUCIAL MARKERS; PROSTATE-GLAND; MOTION; LOCALIZATION; RADIOTHERAPY; ACCURACY; IMAGER;
D O I
10.1088/1361-6560/ac06e3
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Purpose. To estimate 3D prostate motion in real-time during irradiation from 2D prostate positions acquired from a kV imager on a standard linear accelerator utilising a Kalman filter (KF) framework. The advantage of this novel method is threefold: (1) eliminating the need of an initial learning period, therefore reducing patient imaging dose, (2) more robust against measurement noise and (3) more computationally efficient. In this paper, the novel KF method was evaluated in silico using patients' 3D prostate motion and simulated 2D projections. Methods. A KF framework was implemented to estimate 3D motion from 2D projection measurements in real-time during prostate cancer treatments. The noise covariance matrix was adaptively estimated from the previous 10 measurements. This method did not require an initial learning period as the KF process distribution was initialised using a population covariance matrix. This method was evaluated using a ground-truth motion dataset of 17 prostate cancer patients (536 trajectories) measured with electromagnetic transponders. 3D motion was projected onto a rotating imager (SID = 180 cm) (pixel size = 0.388 mm) and rotation speed of 6 degrees/s and 2 degrees/s to simulate VMAT treatments. Gantry-varying additive random noise (<= 5 mm) was added to ground-truth measurements to simulate segmentation error and image quality degradation due to the patient's pelvic bones. For comparison, motion was also estimated using the clinically implemented Gaussian probability density function (PDF) method initialised with 600 projections. Results. Without noise, the 3D root mean square-errors (3D RMSEs) of motion estimated by the KF method were 0.4 +/- 0.1 mm and 0.3 +/- 0.2 mm for 2 degrees/s and 6 degrees/s gantry rotation, respectively. With noise, 3D RMSEs of KF estimated motion were 1.1 +/- 0.1 mm for both slow and fast gantry rotation scenarios. In comparison, using a Gaussian PDF method, with noise, 3D RMSE was 2 +/- 0.1 mm for both gantry rotation scenarios. Conclusion. This work presents a fast and accurate method for real-time 2D to 3D motion estimation using a KF approach to handle the random-walk component of prostate cancer motion. This method has sub-mm accuracy and is highly robust against measurement noise.
引用
收藏
页数:12
相关论文
共 27 条
[1]   Intra-fraction motion of the prostate is a random walk [J].
Ballhausen, H. ;
Li, M. ;
Hegemann, N-S ;
Ganswindt, U. ;
Belka, C. .
PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (02) :549-563
[2]  
Castellanos E., 2012, RADIOTHER ONCOL S1, V103, pS433, DOI [10.1016/S0167-8140(12)71455-X, DOI 10.1016/S0167-8140(12)71455-X]
[3]   Experimental investigation of a general real-time 3D target localization method using sequential kV imaging combined with respiratory monitoring [J].
Cho, Byungchul ;
Poulsen, Per ;
Ruan, Dan ;
Sawant, Amit ;
Keall, Paul J. .
PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (22) :7395-7407
[4]   Reconstruction of implanted marker trajectories from cone-beam CT projection images using interdimensional correlation modeling [J].
Chung, Hyekyun ;
Poulsen, Per Rugaard ;
Keall, Paul J. ;
Cho, Seungryong ;
Cho, Byungchul .
MEDICAL PHYSICS, 2016, 43 (08) :4643-4654
[5]   First MR images obtained during megavoltage photon irradiation from a prototype integrated linac-MR system [J].
Fallone, B. G. ;
Murray, B. ;
Rathee, S. ;
Stanescu, T. ;
Steciw, S. ;
Vidakovic, S. ;
Blosser, E. ;
Tymofichuk, D. .
MEDICAL PHYSICS, 2009, 36 (06) :2084-2088
[6]   Robust automatic segmentation of multiple implanted cylindrical gold fiducial markers in cone-beam CT projections [J].
Fledelius, Walther ;
Worm, Esben ;
Elstrom, Ulrik V. ;
Petersen, Jorgen B. ;
Grau, Cai ;
Hoyer, Morten ;
Poulsen, Per R. .
MEDICAL PHYSICS, 2011, 38 (12) :6351-6361
[7]   The accuracy and precision of the KIM motion monitoring system used in the multi-institutional TROG 15.01 Stereotactic Prostate Ablative Radiotherapy with KIM (SPARK) trial [J].
Hewson, Emily A. ;
Doan Trang Nguyen ;
O'Brien, Ricky ;
Kim, Jung-Ha ;
Montanaro, Tim ;
Moodie, Trevor ;
Greer, Peter B. ;
Hardcastle, Nicholas ;
Eade, Thomas ;
Kneebone, Andrew ;
Hruby, George ;
Hayden, Amy J. ;
Turner, Sandra ;
Siva, Shankar ;
Tai, Keen-Hun ;
Hunter, Perry ;
Sams, Joshua ;
Poulsen, Per Rugaard ;
Booth, Jeremy T. ;
Martin, Jarad ;
Keall, Paul J. .
MEDICAL PHYSICS, 2019, 46 (11) :4725-4737
[8]  
Kalman RE, 1960, Journal ofBasic Engineering, DOI DOI 10.1115/1.3662552
[9]   Stereotactic prostate adaptive radiotherapy utilising kilovoltage intrafraction monitoring: the TROG 15.01 SPARK trial [J].
Keall, Paul ;
Doan Trang Nguyen ;
O'Brien, Ricky ;
Booth, Jeremy ;
Greer, Peter ;
Poulsen, Per ;
Gebski, Val ;
Kneebone, Andrew ;
Martin, Jarad .
BMC CANCER, 2017, 17
[10]   Real-Time 3D Image Guidance Using a Standard LINAC: Measured Motion, Accuracy, and Precision of the First Prospective Clinical Trial of Kilovoltage Intrafraction Monitoring-Guided Gating for Prostate Cancer Radiation Therapy [J].
Keall, Paul J. ;
Ng, Jin Aun ;
Juneja, Prabhjot ;
O'Brien, Ricky T. ;
Huang, Chen-Yu ;
Colvill, Emma ;
Caillet, Vincent ;
Simpson, Emma ;
Poulsen, Per R. ;
Kneebone, Andrew ;
Eade, Thomas ;
Booth, Jeremy T. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 94 (05) :1015-1021