Effect of evaporator tilt on a loop heat pipe with non-condensable gas

被引:31
作者
Wang, Huanfa [1 ]
Lin, Guiping [1 ]
Shen, Xiaobin [1 ,2 ]
Bai, Lizhan [1 ]
Wen, Dongsheng [1 ,2 ]
机构
[1] Beihang Univ, Sch Aeronaut Sci & Engn, Lab Fundamental Sci Ergon & Environm Control, Beijing 100191, Peoples R China
[2] Univ Leeds, Sch Chem & Proc Engn, Leeds LS2 9JT, W Yorkshire, England
基金
中国国家自然科学基金; 北京市自然科学基金;
关键词
Loop heat pipe; Non-condensable gas; Evaporator tilt; Steady state operation; Energy balance; PERFORMANCE; OPERATION;
D O I
10.1016/j.ijheatmasstransfer.2018.09.033
中图分类号
O414.1 [热力学];
学科分类号
摘要
The coupling effect of non-condensable gas (NCG) and evaporator tilts on the steady state operation of a loop heat pipe (LHP) was investigated both experimentally and theoretically in this work. Nitrogen was injected quantitatively into an ammonia-stainless steel LHP to simulate NCG, and the steady state characteristics of the LHP were studied under three typical evaporator tilts. According to the experimental results, the main conclusions below can be drawn. (1) The temperature is the highest under adverse tilt and the lowest under favorable tilt no matter whether there is NCG in LHP. (2) The existence of NCG could cause the increase of temperature under all three typical evaporator tilts, but the temperature increment caused by NCG seems to be relatively small under adverse tilt. (3) The increments of the temperature caused by NCG display different patterns under different tilts. Theoretical analysis was conducted to explain the results: the temperature under the coupling effect of NCG and evaporator tilt was determined by the energy balance between the heat leak from evaporator to compensation chamber and the cooling capacity of returning subcooled liquid. With the increase of heat load, the augmentation of heat leak caused by NCG and the enhancement of subcooled liquid cooling effect were incongruent. The coupling effect of NCG and evaporator tilts should be considered in the terrestrial application of LHP. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1072 / 1080
页数:9
相关论文
共 26 条
[1]  
[Anonymous], 2012, 42 INT C ENV SYST, P1, DOI [10.2514/6.2012-3498, DOI 10.2514/6.2012-3498]
[2]   Effect of evaporator tilt on the operating temperature of a loop heat pipe without a secondary wick [J].
Bai, Lizhan ;
Lin, Guiping ;
Zhang, Hongxing ;
Wen, Dongsheng .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2014, 77 :600-603
[3]  
Baker C., 2011, 41 INT C ENV SYSTEMS, P5209, DOI [10.2514/6.2011-5209, DOI 10.2514/6.2011-5209]
[4]   Steady state operation of a copper-water LHP with a flat-oval evaporator [J].
Becker, S. ;
Vershinin, S. ;
Sartre, V. ;
Laurien, E. ;
Bonjour, J. ;
Maydanik, Yu. F. .
APPLIED THERMAL ENGINEERING, 2011, 31 (05) :686-695
[5]   Steady-state and transient performance of a miniature loop heat pipe [J].
Chen, Yuming ;
Groll, Manfred ;
Mertz, Rainer ;
Maydanik, Yu F. ;
Vershinin, S. V. .
INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2006, 45 (11) :1084-1090
[6]  
Choi M. K., 2011, 41 INT C ENV SYST, P1, DOI [10.2514/6.2011-5098, DOI 10.2514/6.2011-5098]
[7]  
Goncharov K., 2004, 13 INT HEAT PIP C, V1
[8]   Effect of non-condensable gas on the operation of a loop heat pipe [J].
He, Jiang ;
Lin, Guiping ;
Bai, Lizhan ;
Miao, Jianyin ;
Zhang, Hongxing .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2014, 70 :449-462
[9]  
Ishikawa H., 2007, T JPN SOC MECH ENG, V73, P847, DOI DOI 10.1299/KIKAIB.73.847
[10]  
Ku J., 1999, 29 th Int. Conf. Environ. Syst, P16, DOI DOI 10.4271/1999-01-2007