Ambient air monitoring around the dioxin remediation site in Da Nang, Vietnam, using passive air samplers

被引:6
|
作者
Sau, Trinh Khac [1 ]
Truong, Nghiem Xuan [2 ]
Hanh, Tran Thi Tuyet [3 ]
Le Hung, Bao [2 ]
Thang, Nguyen Duc [2 ]
Le Lan Anh, Thi [1 ]
机构
[1] Vietnam Russia Trop Ctr, Inst Biomed, 63 Nguyen Huyen, Hanoi, Vietnam
[2] Vietnam Russia Trop Ctr, Dept Chem Environm, 63 Nguyen Huyen, Hanoi, Vietnam
[3] Hanoi Univ Publ Hlth, Dept Environm Hlth, 1A Duc Thang Rd,Duc Thang Ward, Hanoi, Vietnam
关键词
Passive air sampling; PCDDs; PCDFs; Temporal variation; Agent Orange; Health risk; PERSISTENT ORGANIC POLLUTANTS; DIBENZO-P-DIOXINS; POLYCHLORINATED-BIPHENYLS; ORGANOCHLORINE PESTICIDES; INHALATION RISK; HOT-SPOTS; DL-PCB; PCDD/FS; CITY; INDUSTRIAL;
D O I
10.1007/s10661-021-09223-7
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The concentrations and temporal variations of polychlorodibenzo-p-dioxins and polychlorodibenzofurans (PCDDs/PCDFs) in ambient air between March 2013 and February 2017 were investigated by passive air samplers containing polyurethane foam (PUF) disks in the dioxin remediation area using in-pile thermal desorption (IPTD) technology at Da Nang airport, Vietnam. The PCDD/PCDF concentrations in ambient air at each site depended on the location of the emission sources and the wind direction, the dioxin contamination level of excavated materials, the periods of excavation and transport, and the operation of the IPTD treatment system. The PCDD/PCDF concentrations were the highest in the former Agent Orange mixing and loading area (AOMLA), which was the closest to the IPTD system, with total toxic equivalent (TEQ) values ranging from 0.437 to 15.3 pg/PUF/day. The total TEQ concentrations in the Sen Lake area ranged from 0.138 to 2.41 pg/PUF/day. The lowest concentration of PCDDs/PCDFs occurred in the northern perimeter area, with total TEQ values ranging from 0.164 to 0.972 pg/PUF/day. The decreasing trend of the PCDD/PCDF concentrations in ambient air was confirmed over time at all three monitoring sites, among which there was a strong decrease in the former AOMLA after February 2015. Residents living near the Da Nang airport were at a low risk of being exposed to PCDDs/PCDFs through inhalation during remediation project implementation, while residents living close to the former AOMLA faced elevated risks with an average daily dose of PCDDs/PCDFs through inhalation ranging from 0.017 to 0.82 pg TEQ/kg body weight/day.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] Air quality assessment in Southern Kuwait using diffusive passive samplers
    A. A. Ramadan
    Environmental Monitoring and Assessment, 2010, 160 : 413 - 423
  • [32] Spatial and temporal trends of chiral organochlorine signatures in great lakes air using passive air samplers
    Gouin, T.
    Jantunen, L.
    Harner, T.
    Blanchard, P.
    Bidleman, T.
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2007, 41 (11) : 3877 - 3883
  • [33] Estimation of Air Concentrations of PCBs using Passive Air Samplers (PAS) and a Gas/particle Partition Model
    Baek, Song-Yee
    Choi, Sung-Deuk
    Chang, Yoon-Seok
    JOURNAL OF KOREAN SOCIETY FOR ATMOSPHERIC ENVIRONMENT, 2007, 23 (06) : 734 - 743
  • [34] Review: use of conifer needles as passive samplers of inorganic pollutants in air quality monitoring
    Bertolotti, G.
    Gialanella, S.
    ANALYTICAL METHODS, 2014, 6 (16) : 6208 - 6222
  • [35] Air monitoring with passive samplers for perfluoroalkane substances in developing countries (2017-2019)
    Gonzalez, Pascal Camoiras
    Sadia, Mohammad
    Baabish, Abeer
    Sobhanei, Siamak
    Fiedler, Heidelore
    CHEMOSPHERE, 2021, 282
  • [36] Evaluation of atmospheric sources of PCDD/Fs, PCBs and PBDEs around an MSWI plant using active and passive air samplers
    Li, Mufei
    Zhou, Yanxiao
    Wang, Gaosheng
    Zhu, Guohua
    Zhou, Xin
    Gong, Hongping
    Sun, Junjun
    Wang, Ling
    Liu, Jinsong
    CHEMOSPHERE, 2021, 274
  • [37] Ambient nitrogen dioxide monitoring near a major highway using passive diffusion samplers
    Gilbert, NL
    Stieb, DM
    Woodhouse, S
    Brook, JR
    EPIDEMIOLOGY, 2002, 13 (04) : S146 - S147
  • [38] A method of nitrogen dioxide and sulphur dioxide determination in ambient air by use of passive samplers and ion chromatography
    Krochmal, D
    Kalina, A
    ATMOSPHERIC ENVIRONMENT, 1997, 31 (20) : 3473 - 3479
  • [39] DETERMINATION OF SELECTED ORGANIC POLLUTANTS IN INDOOR AIR USING PERMEATION PASSIVE SAMPLERS
    NAMIESNIK, J
    GORECKI, T
    KOZDRON, B
    TORRES, L
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 1989, 37 (03) : 139 - 147
  • [40] The determination of nitrogen dioxide in ambient air with free hanging filters as passive samplers, and a new calibration method using fritted bubblers
    Heeres, Paul
    Setiawan, Rineksa
    Krol, Maarten Cornelis
    Adema, Eduard Hilbrand
    JOURNAL OF ENVIRONMENTAL MONITORING, 2009, 11 (12): : 2216 - 2221