Ambient air monitoring around the dioxin remediation site in Da Nang, Vietnam, using passive air samplers

被引:6
|
作者
Sau, Trinh Khac [1 ]
Truong, Nghiem Xuan [2 ]
Hanh, Tran Thi Tuyet [3 ]
Le Hung, Bao [2 ]
Thang, Nguyen Duc [2 ]
Le Lan Anh, Thi [1 ]
机构
[1] Vietnam Russia Trop Ctr, Inst Biomed, 63 Nguyen Huyen, Hanoi, Vietnam
[2] Vietnam Russia Trop Ctr, Dept Chem Environm, 63 Nguyen Huyen, Hanoi, Vietnam
[3] Hanoi Univ Publ Hlth, Dept Environm Hlth, 1A Duc Thang Rd,Duc Thang Ward, Hanoi, Vietnam
关键词
Passive air sampling; PCDDs; PCDFs; Temporal variation; Agent Orange; Health risk; PERSISTENT ORGANIC POLLUTANTS; DIBENZO-P-DIOXINS; POLYCHLORINATED-BIPHENYLS; ORGANOCHLORINE PESTICIDES; INHALATION RISK; HOT-SPOTS; DL-PCB; PCDD/FS; CITY; INDUSTRIAL;
D O I
10.1007/s10661-021-09223-7
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The concentrations and temporal variations of polychlorodibenzo-p-dioxins and polychlorodibenzofurans (PCDDs/PCDFs) in ambient air between March 2013 and February 2017 were investigated by passive air samplers containing polyurethane foam (PUF) disks in the dioxin remediation area using in-pile thermal desorption (IPTD) technology at Da Nang airport, Vietnam. The PCDD/PCDF concentrations in ambient air at each site depended on the location of the emission sources and the wind direction, the dioxin contamination level of excavated materials, the periods of excavation and transport, and the operation of the IPTD treatment system. The PCDD/PCDF concentrations were the highest in the former Agent Orange mixing and loading area (AOMLA), which was the closest to the IPTD system, with total toxic equivalent (TEQ) values ranging from 0.437 to 15.3 pg/PUF/day. The total TEQ concentrations in the Sen Lake area ranged from 0.138 to 2.41 pg/PUF/day. The lowest concentration of PCDDs/PCDFs occurred in the northern perimeter area, with total TEQ values ranging from 0.164 to 0.972 pg/PUF/day. The decreasing trend of the PCDD/PCDF concentrations in ambient air was confirmed over time at all three monitoring sites, among which there was a strong decrease in the former AOMLA after February 2015. Residents living near the Da Nang airport were at a low risk of being exposed to PCDDs/PCDFs through inhalation during remediation project implementation, while residents living close to the former AOMLA faced elevated risks with an average daily dose of PCDDs/PCDFs through inhalation ranging from 0.017 to 0.82 pg TEQ/kg body weight/day.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] Applicability of silicone membrane passive samplers for monitoring of indoor air quality
    Zabiegala, B
    Zygmunt, B
    Przyk, E
    Namiesnik, J
    ANALYTICAL LETTERS, 2000, 33 (07) : 1361 - 1372
  • [22] Air concentrations of PCDD/Fs, PCBs and PCNs using active and passive air samplers
    Mari, Montse
    Schuhmacher, Marta
    Feliubadalo, Joan
    Domingo, Jose L.
    CHEMOSPHERE, 2008, 70 (09) : 1637 - 1643
  • [23] Field monitoring of volatile organic compounds using passive air samplers in an industrial city in Japan
    Kume, Kazunari
    Ohura, Takeshi
    Amagai, Takashi
    Fusaya, Masahiro
    ENVIRONMENTAL POLLUTION, 2008, 153 (03) : 649 - 657
  • [24] Screening for PFOS and PFOA in European air using passive samplers
    Chaemfa, Chakra
    Barber, Jonathan L.
    Huber, Sandra
    Breivik, Knut
    Jones, Kevin C.
    JOURNAL OF ENVIRONMENTAL MONITORING, 2010, 12 (05): : 1100 - 1109
  • [25] AIR MONITORING OF SOLVENT EXPOSED WORKERS WITH PASSIVE SAMPLERS IN COMPARISON TO BIOLOGICAL MONITORING (BM)
    TRIEBIG, G
    SCHALLER, KH
    TOXICOLOGICAL AND ENVIRONMENTAL CHEMISTRY, 1986, 12 (3-4): : 285 - 312
  • [26] Calibration of two passive air samplers for monitoring phthalates and brominated flame-retardants in indoor air
    Saini, Amandeep
    Okeme, Joseph O.
    Goosey, Emma
    Diamond, Miriam L.
    CHEMOSPHERE, 2015, 137 : 166 - 173
  • [27] Assessing the feasibility of employing passive air samplers for long-term air quality monitoring programs
    Klanova, Jana
    Cupr, Pavel
    Kohoutek, Jiri
    Holoubek, Ivan
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2007, 233 : 457 - 457
  • [28] Measurement of Ambient Air Pollution with SO2 Applying Lichens and Passive Samplers
    Paliulis, Dainius
    Braduliene, Jolita
    ROCZNIK OCHRONA SRODOWISKA, 2018, 20 : 89 - 108
  • [29] Air quality assessment in Southern Kuwait using diffusive passive samplers
    Ramadan, A. A.
    ENVIRONMENTAL MONITORING AND ASSESSMENT, 2010, 160 (1-4) : 413 - 423
  • [30] Characterization and Quantification of Atmospheric Mercury Sources Using Passive Air Samplers
    McLagan, David S.
    Monaci, Fabrizio
    Huang, Haiyong
    Lei, Ying Duan
    Mitchell, Carl P. J.
    Wania, Frank
    JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES, 2019, 124 (04) : 2351 - 2362