Liquid helium cryostat for SQUID-based MRI receivers

被引:30
|
作者
Seton, HC [1 ]
Hutchison, JMS [1 ]
Bussell, DM [1 ]
机构
[1] Univ Aberdeen, Dept Biomed Phys & Bioengn, Aberdeen AB9 2ZD, Scotland
基金
英国工程与自然科学研究理事会;
关键词
ceramics; liquid helium; SQUIDs; cryostats;
D O I
10.1016/j.cryogenics.2004.11.011
中图分类号
O414.1 [热力学];
学科分类号
摘要
We describe a liquid helium cryostat, developed to cool SQUID-based receivers in low field MRI systems. The cryostat has a 4 L liquid helium capacity, a hold time of over 3 days and accommodates 10 cm diameter receiver coils. New vacuum insulation methods reduce the noise level by at least an order of magnitude compared to existing commercial designs. The minimum detectable field at 425 kHz, with a 5 cm diameter circular coil, was estimated to be 0.018 fT/Hz (1/2) from Q-factor measurements and 0.035 fT/Hz (1/2) by direct measurement with a SQUID amplifier. Further measurements indicated that most of this field noise probably originates with dielectric losses in the cryostat's fibreglass shells. (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:348 / 355
页数:8
相关论文
共 50 条
  • [31] RECORDING UNIT OF SQUID-BASED MAGNETOMETER.
    Drobin, V.M.
    Lobotka, P.
    Trofimov, V.N.
    Instruments and experimental techniques New York, 1987, 30 (3 pt 2): : 673 - 677
  • [32] SQUID-Based Bioassay with Magnetic Particles in Flow
    Espy, M. A.
    Carr, C.
    Sandin, J. H.
    Hanson, C. J.
    Daniels, S. G.
    Matlachov, A. N.
    Graves, S. W.
    Ward, M. D.
    Kraus, R. H., Jr.
    Fritz, S.
    Leslie-Pelecky, D.
    7TH EUROPEAN CONFERENCE ON APPLIED SUPERCONDUCTIVITY (EUCAS'05), 2006, 43 : 1254 - 1257
  • [33] ULTIMATE SENSITIVITY OF SQUID-BASED WIDEBAND AMPLIFIERS
    SNIGIREV, OV
    RADIOTEKHNIKA I ELEKTRONIKA, 1988, 33 (06): : 1284 - 1289
  • [34] AN AUTOMATIC TEMPERATURE CONTROL FOR A LIQUID HELIUM CRYOSTAT
    ANDREW, ER
    JOURNAL OF SCIENTIFIC INSTRUMENTS AND OF PHYSICS IN INDUSTRY, 1948, 25 (12): : 416 - 417
  • [35] PORTABLE LIQUID-HELIUM LABORATORY CRYOSTAT
    VIDWANS, VV
    RATNAM, BA
    CRYOGENICS, 1975, 15 (07) : 423 - 424
  • [36] A HELIUM CRYOSTAT WITHOUT COOLING BY LIQUID NITROGEN
    FRADKOV, AB
    DOKLADY AKADEMII NAUK SSSR, 1960, 133 (04): : 829 - 830
  • [37] LIQUID HELIUM CRYOSTAT FOR MOSSBAUER SCATTERING EXPERIMENTS
    BARRETT, PH
    GRODZINS, L
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1965, 36 (11): : 1607 - &
  • [38] CRYOSTAT FOR CYCLOTRON IRRADIATION AT LIQUID HELIUM TEMPERATURES
    MAPOTHER, DE
    WITT, FEL
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1955, 26 (09): : 843 - 846
  • [39] LIQUID HELIUM CRYOSTAT FOR RESISTANCE THERMOMETER CALIBRATION
    DUDA, CR
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1968, 39 (10): : 1484 - &
  • [40] A SMALL-SCALE LIQUID HELIUM CRYOSTAT
    CROFT, AJ
    THOMAS, JO
    CRYOGENICS, 1969, 9 (01) : 57 - &