Coded-aperture imaging systems: Past, present and future development - A review

被引:139
作者
Cieslak, Michal J. [1 ]
Gamage, Kelum A. A. [1 ]
Glover, Robert [2 ]
机构
[1] Univ Lancaster, Dept Engn, Lancaster LA1 4YW, England
[2] Sellafield Ltd, Radiometr Syst Grp, Seascale CA20 1PG, England
基金
英国工程与自然科学研究理事会;
关键词
Coded-aperture; Neutron detection; Radiation imaging; Monte Carlo modelling; PULSE-SHAPE DISCRIMINATION; GAMMA-RAY IMAGER; X-RAY; NEUTRON DETECTORS; MONTE-CARLO; CAMERA; PERFORMANCE; EMISSION; HE-3; COLLIMATOR;
D O I
10.1016/j.radmeas.2016.08.002
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Scintillator based coded-aperture imaging has proven to be effective when applied for X- and gamma-ray detection. Adaptation of the same method for neutron imaging has resulted in a number of propitious systems, which could be potentially employed for neutron detection in security and nuclear decommissioning applications. Recently developed scintillator based coded-aperture imagers reveal that localisation of neutron sources using this technique may be feasible, since pulse shape discrimination algorithms implemented in the digital doinain can reliably separate gamma-rays from fast neutron interactions occurring within an organic scintillator. Moreover, recent advancements in the development of solid organic scintillators make them a viable solution for nuclear decommissioning applications as they present less hazardous characteristics than currently dominating liquid scintillation detectors. In this paper existing applications of coded-apertures for radiation detection are critically reviewed, highlighting potential improvements for coded-aperture based neutron source localisation. Further, the suitability of coded-apertures for neutron imaging in nuclear decommissioning is also assessed using Monte-Carlo modelling. (C) 2016 The Authors. Published by Elsevier Ltd.
引用
收藏
页码:59 / 71
页数:13
相关论文
共 84 条
[1]  
Ables J. G., 1968, Proceedings of the Astronomical Society of Australia, V1, P172
[2]  
Accorsi R, 2001, IEEE T NUCL SCI, V48, P2411, DOI 10.1109/23.983251
[3]   VERSATILE PULSE SHAPE DISCRIMINATOR FOR CHARGED-PARTICLE SEPARATION AND ITS APPLICATION TO FAST-NEUTRON TIME-OF-FLIGHT SPECTROSCOPY [J].
ADAMS, JM ;
WHITE, G .
NUCLEAR INSTRUMENTS & METHODS, 1978, 156 (03) :459-476
[4]   Preliminary Monte Carlo study of coded aperture imaging with a CZT gamma camera system for scintimammography [J].
Alnafea, M. ;
Wells, K. ;
Spyrou, N. M. ;
Guy, M. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 573 (1-2) :122-125
[5]   Preliminary results from a Monte Carlo study of breast tumour imaging with low-energy high-resolution collimator and a modified uniformly-redundant array-coded aperture [J].
Alnafea, M. ;
Wells, K. ;
Spyrou, N. M. ;
Saripana, M. I. ;
Guy, M. ;
Hinton, P. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 563 (01) :146-149
[6]  
[Anonymous], 2014, EJ-299-33A PSD Plastic Scintillator
[7]  
[Anonymous], 2001, THESIS
[8]   Development of a pinhole gamma camera for environmental monitoring [J].
Baek, Cheol-Ha ;
An, Su Jung ;
Kim, Hyun-il ;
Kwak, Sung-Woo ;
Chung, Yong Hyun .
RADIATION MEASUREMENTS, 2013, 59 :114-118
[9]   Neutron assay in mixed radiation fields with a 6Li-loaded plastic scintillator [J].
Balmer, M. J. I. ;
Gamage, K. A. A. ;
Taylor, G. C. .
JOURNAL OF INSTRUMENTATION, 2015, 10
[10]  
Bélanger G, 2004, ASTROPHYS J, V601, pL163, DOI 10.1086/381738