Overview of Therapeutic Ultrasound Applications and Safety Considerations

被引:472
作者
Miller, Douglas L. [1 ]
Smith, Nadine B. [2 ]
Bailey, Michael R. [3 ]
Czarnota, Gregory J. [4 ]
Hynynen, Kullervo [5 ]
Makin, Inder Raj S. [6 ,7 ]
机构
[1] Univ Michigan, Dept Radiol, Ann Arbor, MI 48109 USA
[2] Penn State Univ, Dept Bioengn, University Pk, PA 16802 USA
[3] Univ Washington, Appl Phys Lab, Seattle, WA 98105 USA
[4] Sunnybrook Hlth Sci Ctr, Sunnybrook Res Inst, Toronto, ON M4N 3M5, Canada
[5] Univ Toronto, Dept Med Biophys, Toronto, ON, Canada
[6] AT Still Univ, Sch Osteopath Med, Mesa, AZ USA
[7] AT Still Univ, Arizona Sch Dent, Mesa, AZ USA
关键词
medical ultrasound devices; therapeutic ultrasound; ultrasound safety; INTENSITY FOCUSED ULTRASOUND; SHOCK-WAVE LITHOTRIPSY; PULMONARY VEIN ISOLATION; BLOOD-BRAIN-BARRIER; PULSED ULTRASOUND; PROSTATE-CANCER; ABLATION; SURGERY; SKIN; TUMORS;
D O I
10.7863/jum.2012.31.4.623
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Applications of ultrasound in medicine for therapeutic purposes have been accepted and beneficial uses of ultrasonic biological effects for many years. Low-power ultrasound of about 1 MHz has been widely applied since the 1950s for physical therapy in conditions such as tendinitis and bursitis. In the 1980s, high-pressure-amplitude shock waves came into use for mechanically resolving kidney stones, and "lithotripsy" rapidly replaced surgery as the most frequent treatment choice. The use of ultrasonic energy for therapy continues to expand, and approved applications now include uterine fibroid ablation, cataract removal (phacoemulsification), surgical tissue cutting and hemostasis, transdermal drug delivery, and bone fracture healing, among others. Undesirable bioeffects can occur, including burns from thermal-based therapies and severe hemorrhage from mechanical-based therapies (eg, lithotripsy). In all of these therapeutic applications of ultrasound bioeffects, standardization, ultrasound dosimetry, benefits assurance, and side-effect risk minimization must be carefully considered to ensure an optimal benefit to risk ratio for the patient. Therapeutic ultrasound typically has well-defined benefits and risks and therefore presents a manageable safety problem to the clinician. However, safety information can be scattered, confusing, or subject to commercial conflicts of interest. Of paramount importance for managing this problem is the communication of practical safety information by authoritative groups, such as the American Institute of Ultrasound in Medicine, to the medical ultrasound community. In this overview, the Bioeffects Committee of the American Institute of Ultrasound in Medicine outlines the wide range of therapeutic ultrasound methods, which are in clinical use or under study, and provides general guidance for ensuring therapeutic ultrasound safety.
引用
收藏
页码:623 / 634
页数:12
相关论文
共 104 条
  • [1] Ultrasound tightening of facial and neck skin: A rater-blinded prospective cohort study
    Alam, Murad
    White, Lucile E.
    Martin, Nicolle
    Witherspoon, Joslyn
    Yoo, Simon
    West, Dennis P.
    [J]. JOURNAL OF THE AMERICAN ACADEMY OF DERMATOLOGY, 2010, 62 (02) : 262 - 269
  • [2] Exposure to Low Amounts of Ultrasound Energy Does Not Improve Soft Tissue Shoulder Pathology: A Systematic Review
    Alexander, Lisa D.
    Gilman, David R. D.
    Brown, Derek R.
    Brown, Janet L.
    Houghton, Pamela E.
    [J]. PHYSICAL THERAPY, 2010, 90 (01): : 14 - 25
  • [3] The use of extracorporeal shock waves in the treatment of osteonecrosis of the femoral head: a systematic review
    Alves, Eneida Machado
    Angrisani, Adriano Tanajura
    Santiago, Mittermayer B.
    [J]. CLINICAL RHEUMATOLOGY, 2009, 28 (11) : 1247 - 1251
  • [4] NONINVASIVE DETERMINATION OF IN SITU HEATING RATE USING kHz ACOUSTIC EMISSIONS AND FOCUSED ULTRASOUND
    Anand, Ajay
    Kaczkowski, Peter J.
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2009, 35 (10) : 1662 - 1671
  • [5] [Anonymous], J ULTRASOUND MED
  • [6] [Anonymous], ULTRASONIC EXPOSIMET
  • [7] [Anonymous], 1998, NONLINEAR ACOUSTICS
  • [8] [Anonymous], 140 NAT COUNC RAD PR
  • [9] [Anonymous], 1981, Ultrasonics, DOI [DOI 10.1016/S0076-695X(08)60338-5, 10.1016/S0076-695X(08)60338-5]
  • [10] [Anonymous], 015 DQL AC NAT PHYS