Radial dose functions of GZP6 intracavitary brachytherapy 60Co sources: treatment planning system versus Monte Carlo calculations

被引:0
|
作者
Mesbahi, A. [1 ,2 ]
机构
[1] Tabriz Univ Med Sci, Dept Med Phys, Sch Med, Tabriz, Iran
[2] Tabriz Univ Med Sci, Imam Khomeini Hosp, Dept Radiat Oncol, Tabriz, Iran
来源
IRANIAN JOURNAL OF RADIATION RESEARCH | 2008年 / 5卷 / 04期
关键词
Brachytherapy; high dose rate (HDR); Co-60; Monte Carlo;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: The Monte Carlo (MC) method is not only used for dose calculations around brachytherapy sources but also for benchmarking treatment planning systems (TPS) calculations. Materials and Methods: Three Co-60 sources of GZP6 brachytherapy unit were simulated using MCNP4C MC Code. The radial dose functions were calculated by MC method and GZP6 TPS and were compared. Results: There was a good agreement between MC and TPS calculations for all sources. Discrepancies up to 10% were observed for points close to the sources, but for those farther than 7 mm from source center, differences were less than 2% for all sources. Conclusion: Our results showed that GZP6 TPS calculations can accurately be used for dose calculations in brachytherapy treatments for points farther than 7 mm from the source center. Iran. J. Radiat. Res., 2008; 5 (4): 181-186
引用
收藏
页码:181 / 186
页数:6
相关论文
共 28 条
  • [1] Dosimetric study of GZP6 60Co high dose rate brachytherapy source
    Lei, Qin
    Xu, Anjian
    Gou, Chengjun
    Wen, Yumei
    He, Donglin
    Wu, Junxiang
    Hou, Qing
    Wu, Zhangwen
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2018, 19 (04): : 313 - 318
  • [2] Introducing a Complementary Treatment Planning Software for GZP6 Brachytherapy System GZP6 Complementary Treatment Planning Software (GZP6 CTPS)
    Hariri, Sanaz
    Asl, Alireza Kamali
    2010 3RD INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS (BMEI 2010), VOLS 1-7, 2010, : 1350 - 1352
  • [3] Dosimetric characterizations of GZP6 60Co high dose rate brachytherapy sources: application of superimposition method
    Toossi, Mohammad Taghi Bahreyni
    Ghorbani, Mahdi
    Mowlavi, Ali Asghar
    Meigooni, Ali Soleimani
    RADIOLOGY AND ONCOLOGY, 2012, 46 (02) : 170 - 178
  • [4] Monte Carlo dosimetry of the 60Co sources of a new GZP3 HDR afterloading system
    Wu, Junxiang
    Kang, Shengwei
    Wang, Pei
    Li, Jie
    Wang, Xianliang
    RADIATION ONCOLOGY, 2023, 18 (01)
  • [5] Monte Carlo dosimetry of 60Co HDR brachytherapy sources
    Papagiannis, P
    Angelopoulos, A
    Pantelis, E
    Sakelliou, L
    Karaiskos, P
    Shimizu, Y
    MEDICAL PHYSICS, 2003, 30 (04) : 712 - 721
  • [6] A Monte Carlo study on dose distribution validation of GZP6 Co-60 stepping source
    Toossi, Mohammad Taghi Bahreyni
    Abdollahi, Maliheh
    Ghorbani, Mahdi
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2013, 18 (02) : 112 - 116
  • [7] Monte Carlo dose calculation of GZP6 Co-60 stepping source based on a matrix shift technique
    Toossi, Mohammad Taghi Bahreyni
    Abdollahi, Malihe
    Ghorbani, Mahdi
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2011, 16 (01) : 10 - 13
  • [8] Monte Carlo dosimetry of the 60Co sources of a new GZP3 HDR afterloading system
    Junxiang Wu
    Shengwei Kang
    Pei Wang
    Jie Li
    Xianliang Wang
    Radiation Oncology, 18
  • [9] Monte Carlo derivation of AAPM TG-43 dosimetric parameters for GZP6 Co-60 HDR sources
    Tabrizi, Sanaz Hariri
    Asl, Alireza Kamali
    Azma, Zohreh
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2012, 28 (02): : 153 - 160
  • [10] A Monte Carlo investigation of the dose distribution for 60Co high dose rate brachytherapy source in water and in different media
    Badry, Hamza
    Oufni, Lhoucine
    Ouabi, Hmad
    Hirayama, Hideo
    APPLIED RADIATION AND ISOTOPES, 2018, 136 : 104 - 110