Volatile polar metabolites in exhaled breath condensate (EBC): collection and analysis

被引:28
作者
Pleil, Joachim D. [1 ]
Hubbard, Heidi F. [1 ]
Sobus, Jon R. [1 ,2 ]
Sawyer, Keegan [2 ]
Madden, Michael C. [3 ]
机构
[1] US EPA, Human Exposure & Atmospher Sci Div, Natl Exposure Res Lab, Off Res & Dev, Res Triangle Pk, NC 27711 USA
[2] Univ N Carolina, Sch Publ Hlth, Chapel Hill, NC 27599 USA
[3] US EPA, Human Studies Div, Natl Hlth & Environm Effects Lab, Off Res & Dev, Chapel Hill, NC 27599 USA
关键词
D O I
10.1088/1752-7155/2/2/026001
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Environmental exposures, individual activities and disease states can perturb normal metabolic processes and be expressed as a change in the patterns of polar volatile organic compounds (PVOCs) present in biological fluids. We explore the measurement of volatile endogenous biomarkers to infer previous exposures to complex mixtures of environmental stressors. It is difficult to extract such compounds for ultra-trace level analysis due to their high solubility in water, especially when assaying complex liquid biological media such as exhaled breath condensate (EBC). Existing methods tend to be limited in sample volume processed and restricted in sample throughput. We have developed an alternative passive extraction method wherein a 2 ml sample is injected into a 75 ml glass bulb creating a small pool of liquid; a standard Tenax (R) sampling tube is inserted above the fluid and allowed to equilibrate with the headspace for similar to 24 h. The biomarker compounds are preferentially transferred by diffusion from the aqueous sample onto the Tenax (R) adsorbent; blanks and calibration samples are similarly processed. Numerous samples can be simultaneously prepared and stored awaiting routine analysis for a suite of alcohols and aldehydes using thermal desorption gas chromatography-mass spectrometry (GC-MS). We have optimized the procedures and estimated the sensitivity, precision and extraction efficiency resulting from the preparation and analytical procedures using synthetic samples. We subsequently demonstrated the method using anonymous biological specimens of EBC from healthy adults. The ultimate goal is to develop normal ranges and patterns for PVOCs to infer population-based environmental health states with simple spot measurements based on outlier determinations.
引用
收藏
页数:9
相关论文
共 39 条
  • [1] AMANN A, 2005, BREATH ANAL CLIN DIA
  • [2] [Anonymous], 1997, BASIC GAS CHROMATOGR
  • [3] Sorptive sample preparation - a review
    Baltussen, E
    Cramers, CA
    Sandra, PJF
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2002, 373 (1-2) : 3 - 22
  • [4] Analysis and stability of aldehydes and terpenes in electropolished canisters
    Batterman, SA
    Zhang, GZ
    Baumann, M
    [J]. ATMOSPHERIC ENVIRONMENT, 1998, 32 (10) : 1647 - 1655
  • [5] Survey of volatile organic compounds associated with automative emissions in the urban airshed of Sao Paulo, Brazil
    Colón, M
    Pleil, JD
    Hartlage, TA
    Guardani, ML
    Martins, MH
    [J]. ATMOSPHERIC ENVIRONMENT, 2001, 35 (23) : 4017 - 4031
  • [6] Sample preparation for the analysis of volatile organic compounds in air and water matrices
    Demeestere, Kristof
    Dewulf, Jo
    De Witte, Bavo
    Van Langenhove, Herman
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2007, 1153 (1-2) : 130 - 144
  • [7] Measuring the metabolome: current analytical technologies
    Dunn, WB
    Bailey, NJC
    Johnson, HE
    [J]. ANALYST, 2005, 130 (05) : 606 - 625
  • [8] Determinants of temporal variability in NHEXAS-Maryland environmental concentrations, exposures, and biomarkers
    Egeghy, PP
    Quackenboss, JJ
    Sandra, CC
    Ryan, PB
    [J]. JOURNAL OF EXPOSURE ANALYSIS AND ENVIRONMENTAL EPIDEMIOLOGY, 2005, 15 (05): : 388 - 397
  • [9] *EPA, 2007, WAT SCI AN METH
  • [10] *EPA, 2007, AIR TOX METH COMP