General ultrafast pulse measurement using the cross-correlation single-shot sonogram technique

被引:4
作者
Reid, DT [1 ]
Garduno-Mejia, J [1 ]
机构
[1] Heriot Watt Univ, Ultrafast Opt Grp, Dept Phys, Sch Engn & Phys Sci, Edinburgh EH14 4AS, Midlothian, Scotland
关键词
D O I
10.1364/OL.29.000644
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The cross-correlation single-shot sonogram technique offers exact pulse measurement and real-time pulse monitoring via an intuitive time-frequency trace whose shape and orientation directly indicate the spectral chirp of an ultrashort laser pulse. We demonstrate an algorithm that solves a fundamental limitation of the cross-correlation sonogram method, namely, that the time-gating operation is implemented using a replica of the measured pulse rather than the ideal delta-function-like pulse. Using a modified principal-components generalized projections algorithm, we experimentally show accurate pulse retrieval of an asymmetric double pulse, a case that is prone to systematic error when one is using the original sonogram retrieval algorithm. (C) 2004 Optical Society of America.
引用
收藏
页码:644 / 646
页数:3
相关论文
共 50 条
[41]   Single-shot observation of growing streamers using an ultrafast camera [J].
Takahashi, E. ;
Kato, S. ;
Furutani, H. ;
Sasaki, A. ;
Kishimoto, Y. ;
Takada, K. ;
Matsumura, S. ;
Sasaki, H. .
JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2011, 44 (30)
[42]   Measurement of the single-shot pulse energy of a free electron laser using a cryogenic radiometer [J].
Kato, Masahiro ;
Saito, Norio ;
Tiedtke, Kai ;
Juranic, Pavle N. ;
Sorokin, Andrey A. ;
Richter, Mathias ;
Morishita, Yuichiro ;
Tanaka, Takahiro ;
Jastrow, Ulf ;
Kroth, Udo ;
Schoeppe, Hendrik ;
Nagasono, Mitsuru ;
Yabashi, Makina ;
Tono, Kensuke ;
Togashi, Tadashi ;
Kimura, Hiroaki ;
Ohashi, Haruhiko ;
Ishikawa, Tetsuya .
METROLOGIA, 2010, 47 (05) :518-521
[44]   Single-shot cross-correlator using a long-wavelength sampling pulse [J].
Ma, Jingui ;
Yuan, Peng ;
Wang, Yongzhi ;
Zhang, Dongfang ;
Zhu, Heyuan ;
Qian, Liejia .
OPTICS LETTERS, 2011, 36 (06) :978-980
[45]   Ultrafast single-shot imaging of femtosecond pulse propagation in transparent liquids using a supercontinuum and optical polarigraphy [J].
Wang, Xiaofang ;
Si, Jinhai ;
Yan, Lihe ;
He, Pengchao ;
Chen, Feng ;
Hou, Xun .
JOURNAL OF OPTICS, 2014, 16 (01)
[46]   Single-shot pulse-contrast measurement based on high-orderquasi-phase-matchingcross-correlation [J].
Ma, Jingui ;
Wang, Yongzhi ;
Yuan, Peng ;
Xie, Guoqiang ;
Zhu, Heyuan ;
Qian, Liejia .
OPTICS LETTERS, 2012, 37 (21) :4486-4488
[47]   Modified spectrum autointerferometric correlation (MOSAIC) for single-shot pulse characterization [J].
Bender, Daniel A. ;
Sheik-Bahae, Mansoor .
OPTICS LETTERS, 2007, 32 (19) :2822-2824
[48]   Extremely broadband single-shot cross-correlation frequency-resolved optical gating using a transient grating as gate and dispersive element [J].
Valtna-Lukner, H. ;
Belli, F. ;
Ermolov, A. ;
Koettig, F. ;
Mak, K. F. ;
Tani, F. ;
Travers, J. C. ;
Russell, P. St. J. .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2017, 88 (07)
[49]   COMMENTS ON THE PICOSECOND PULSE WIDTH MEASUREMENT BY THE SINGLE-SHOT 2ND HARMONIC BEAM TECHNIQUE [J].
ARAKELIAN, SA ;
GYUZALIAN, RN ;
SOGOMONIAN, SB .
OPTICS COMMUNICATIONS, 1982, 44 (01) :67-72
[50]   Single-shot measurement of the complete spatiotemporal field of an ultrashort laser pulse [J].
Gabolde, Pablo ;
Trebino, Rick .
PHOTONICS NORTH 2006, PTS 1 AND 2, 2006, 6343