A multislice single breath-hold scheme for imaging alveolar oxygen tension in humans

被引:19
作者
Hamedani, Hooman [1 ]
Kadlecek, Stephen J. [1 ]
Emami, Kiarash [1 ]
Kuzma, Nicholas N. [1 ]
Xu, Yinan [1 ]
Xin, Yi [1 ]
Mongkolwisetwara, Puttisarn [1 ]
Rajaei, Jennia [1 ]
Barulic, Amy [1 ]
Miller, G. Wilson [2 ]
Rossman, Milton [3 ]
Ishii, Masaru [1 ,4 ]
Rizi, Rahim R. [1 ]
机构
[1] Univ Penn, Dept Radiol, Philadelphia, PA 19104 USA
[2] Univ Penn, Pulm Allergy & Crit Care Div, Philadelphia, PA 19104 USA
[3] Univ Virginia, Dept Radiol, Charlottesville, VA USA
[4] Johns Hopkins Univ, Dept Otolaryngol Head & Neck Surg, Baltimore, MD USA
关键词
alveolar partial pressure of oxygen; hyperpolarized helium-3; magnetic resonance imaging; lung; respiration; PULMONARY PARTIAL-PRESSURE; HYPERPOLARIZED HE-3; DEPLETION RATE; HUMAN LUNG; REPRODUCIBILITY; VENTILATION; RELAXATION; DIFFUSION; HEALTHY; PO(2);
D O I
10.1002/mrm.23125
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Reliable, noninvasive, and high-resolution imaging of alveolar partial pressure of oxygen (pAO2) is a potentially valuable tool in the early diagnosis of pulmonary diseases. Several techniques have been proposed for regional measurement of pAO2 based on the increased depolarization rate of hyperpolarized 3He. In this study, we explore one such technique by applying a multislice pAO2-imaging scheme that uses interleaved-slice ordering to utilize interslice time-delays more efficiently. This approach addresses the low spatial resolution and long breath-hold requirements of earlier techniques, allowing pAO2 measurements to be made over the entire human lung in 1015 s with a typical resolution of 8.3 X 8.3 X 15.6 mm3. PO2 measurements in a glass syringe phantom were in agreement with independent gas analysis within 4.7 +/- 4.1% (R = 0.9993). The technique is demonstrated in four human subjects (healthy nonsmoker, healthy former smoker, healthy smoker, and patient with COPD), each imaged six times on 3 different days during a 2-week span. Two independent measurements were performed in each session, consisting of 12 coronal slices. The overall pAO2 mean across all subjects was 95.9 +/- 12.2 Torr and correlated well with end-tidal O2 (R = 0.805, P < 0.0001). The alveolar O2 uptake rate was consistent with the expected range of 12 Torr/s. Repeatable visual features were observed in pAO2 maps over different days, as were characteristic differences among the subjects and gravity-dependent effects. Magn Reson Med, 2012. (c) 2011 Wiley Periodicals, Inc.
引用
收藏
页码:1332 / 1345
页数:14
相关论文
共 30 条
[1]   Polarization of 3He by spin exchange with optically pumped Rb and K vapors [J].
Baranga, ABA ;
Appelt, S ;
Romalis, MV ;
Erickson, CJ ;
Young, AR ;
Cates, GD ;
Happer, W .
PHYSICAL REVIEW LETTERS, 1998, 80 (13) :2801-2804
[2]   Sequential VA/Q distributions in the normal rabbit by micropore membrane inlet mass spectrometry [J].
Baumgardner, JE ;
Choi, IC ;
Vonk-Noordegraaf, A ;
Frasch, HF ;
Neufeld, GR ;
Marshall, BE .
JOURNAL OF APPLIED PHYSIOLOGY, 2000, 89 (05) :1699-1708
[3]   Modeling of end-tidal and arterial PCO2 gradient:: comparison with experimental data [J].
Benallal, H ;
Denis, C ;
Prieur, F ;
Busso, T .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2002, 34 (04) :622-629
[4]   Alveolar oxygen partial pressure and oxygen depletion rate mapping in rats using 3He ventilation imaging [J].
Cieslar, Katarzyna ;
Stupar, Vasile ;
Canet-Soulas, Emmanuelle ;
Gaillard, Sophie ;
Cremillieux, Yannick .
MAGNETIC RESONANCE IN MEDICINE, 2007, 57 (02) :423-430
[5]  
Deninger AJ, 2000, NMR BIOMED, V13, P194, DOI 10.1002/1099-1492(200006)13:4<194::AID-NBM643>3.0.CO
[6]  
2-D
[7]   Improved Technique for Measurement of Regional Fractional Ventilation by Hyperpolarized 3He MRI [J].
Emami, Kiarash ;
Kadlecek, Stephen J. ;
Woodburn, John M. ;
Zhu, Jianliang ;
Yu, Jiangsheng ;
Vahdat, Vahid ;
Pickup, Stephen ;
Ishii, Masaru ;
Rizi, Rahim R. .
MAGNETIC RESONANCE IN MEDICINE, 2010, 63 (01) :137-150
[8]   Measurements of regional alveolar oxygen pressure using hyperpolarized 3He MRI [J].
Fischer, MC ;
Kadlecek, S ;
Yu, JS ;
Ishii, M ;
Emami, K ;
Vahdat, V ;
Lipson, DA ;
Rizi, RR .
ACADEMIC RADIOLOGY, 2005, 12 (11) :1430-1439
[9]   Single-acquisition sequence for the measurement of oxygen partial pressure by hyperpolarized gas MRI [J].
Fischer, MC ;
Spector, ZZ ;
Ishii, M ;
Yu, J ;
Emami, K ;
Itkin, M ;
Rizi, R .
MAGNETIC RESONANCE IN MEDICINE, 2004, 52 (04) :766-773
[10]   THE RICIAN DISTRIBUTION OF NOISY MRI DATA [J].
GUDBJARTSSON, H ;
PATZ, S .
MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (06) :910-914