Automated Breast Ultrasound System for Breast Cancer Evaluation: Diagnostic Performance of the Two-View Scan Technique in Women with Small Breasts

被引:16
|
作者
Kwon, Bo Ra [1 ,2 ]
Chang, Jung Min [1 ]
Kim, Soo Yeon [1 ]
Lee, Su Hyun [1 ]
Kim, Soo-Yeon [1 ]
Lee, So Min [1 ]
Cho, Nariya [1 ]
Moon, Woo Kyung [1 ]
机构
[1] Seoul Natl Univ, Seoul Natl Univ Hosp, Dept Radiol, Coll Med, Seoul, South Korea
[2] Seoul Natl Univ Hosp, Dept Radiol, Gangnam Ctr, Healthcare Syst, Seoul, South Korea
关键词
Breast cancer; Automated breast ultrasound system; Scan technique; Diagnostic performance; Small breasts; HAND-HELD ULTRASOUND; B-MODE ULTRASOUND; VOLUME SCANNER; LESION DETECTION; MAMMOGRAPHY; HHUS; DIFFERENTIATION; RISK; US;
D O I
10.3348/kjr.2019.0275
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To comparatively evaluate the scan coverage and diagnostic performance of the two-view scan technique (2-VST) of the automated breast ultrasound system (ABUS) versus the conventional three-view scan technique (3-VST) in women with small breasts. Materials and Methods: Between March 2016 and May 2017, 136 asymptomatic women with small breasts (bra cup size A) suitable for 2-VST were enrolled. Subsequently, 272 breasts were subjected to bilateral whole-breast ultrasound examinations using ABUS and the hand-held ultrasound system (HHUS). During ABUS image acquisition, one breast was scanned with 2-VST, while the other breast was scanned with 3-VST. In each breast, the breast coverage and visibility of the HHUS detected lesions on ABUS were assessed. The sensitivity and specificity of ABUS were compared between 2-VST and 3-VST. Results: Among 136 breasts, eight cases of breast cancer were detected by 2-VST, and 10 cases of breast cancer were detected by 3-VST. The breast coverage was satisfactory in 94.1% and 91.9% of cases under 2-VST and 3-VST, respectively (p = 0.318). All HHUS-detected lesions were visible on the ABUS images regardless of the scan technique. The sensitivities and specificities were similar between 2-VST and 3-VST (100% [8/8] vs. 100% [10/10], and 97.7% [125/128] vs. 95.2% [120/126], respectively), with no significant difference (p > 0.05). Conclusion: 2-VST of ABUS achieved comparable scan coverage and diagnostic performance to that of conventional 3-VST in women with small breasts.
引用
收藏
页码:25 / 32
页数:8
相关论文
共 50 条
  • [21] Diagnostic performances of supplemental breast ultrasound screening in women with personal history of breast cancer
    Song, Sung Eun
    Cho, Nariya
    Chang, Jung Min
    Chu, A. Jung
    Yi, Ann
    Moon, Woo Kyung
    ACTA RADIOLOGICA, 2018, 59 (05) : 533 - 539
  • [22] Interpretation Time Using a Concurrent-Read Computer-Aided Detection System for Automated Breast Ultrasound in Breast Cancer Screening of Women With Dense Breast Tissue
    Jiang, Yulei
    Inciardi, Marc F.
    Edwards, Alexandra, V
    Papaioannou, John
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2018, 211 (02) : 452 - 461
  • [23] Automated volumetric breast density measures: differential change between breasts in women with and without breast cancer
    Brandt, Kathleen R.
    Scott, Christopher G.
    Miglioretti, Diana L.
    Jensen, Matthew R.
    Mahmoudzadeh, Amir P.
    Hruska, Carrie
    Ma, Lin
    Wu, Fang Fang
    Cummings, Steven R.
    Norman, Aaron D.
    Engmann, Natalie J.
    Shepherd, John A.
    Winham, Stacey J.
    Kerlikowske, Karla
    Vachon, Celine M.
    BREAST CANCER RESEARCH, 2019, 21 (01)
  • [24] Automated volumetric breast density measures: differential change between breasts in women with and without breast cancer
    Kathleen R. Brandt
    Christopher G. Scott
    Diana L. Miglioretti
    Matthew R. Jensen
    Amir P. Mahmoudzadeh
    Carrie Hruska
    Lin Ma
    Fang Fang Wu
    Steven R. Cummings
    Aaron D. Norman
    Natalie J. Engmann
    John A. Shepherd
    Stacey J. Winham
    Karla Kerlikowske
    Celine M. Vachon
    Breast Cancer Research, 21
  • [25] Automated Breast Ultrasound in Breast Cancer Screening of Women With Dense Breasts: Reader Study of Mammography-Negative and Mammography-Positive Cancers
    Giger, Maryellen L.
    Inciardi, Marc F.
    Edwards, Alexandra
    Papaioannou, John
    Drukker, Karen
    Jiang, Yulei
    Brem, Rachel
    Brown, Jeremy Bancroft
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2016, 206 (06) : 1341 - 1350
  • [26] A multicenter hospital-based diagnosis study of automated breast ultrasound system in detecting breast cancer among Chinese women
    Zhang, Xi
    Lin, Xi
    Tan, Yanjuan
    Zhu, Ying
    Wang, Hui
    Feng, Ruimei
    Tang, Guoxue
    Zhou, Xiang
    Li, Anhua
    Qiao, Youlin
    CHINESE JOURNAL OF CANCER RESEARCH, 2018, 30 (02) : 231 - 239
  • [27] Improved breast cancer detection in asymptomatic women using 3D-automated breast ultrasound in mammographically dense breasts
    Giuliano, Vincenzo
    Giuliano, Concetta
    CLINICAL IMAGING, 2013, 37 (03) : 480 - 486
  • [28] Breast cancer screening: Evidence of the effect of adjunct ultrasound screening in women with unilateral mammography-negative dense breasts
    Adibi, Atoosa
    Golshahi, Maryam
    Sirus, Mehri
    Kazemi, Kimia
    JOURNAL OF RESEARCH IN MEDICAL SCIENCES, 2015, 20 (03): : 228 - 232
  • [29] A Prospective Comparative Evaluation of Handheld Ultrasound Examination (HHUS) or Automated Ultrasound Examination (ABVS) in Women with Dense Breast
    Brunetti, Nicole
    De Giorgis, Sara
    Tosto, Simona
    Garlaschi, Alessandro
    Rescinito, Giuseppe
    Massa, Barbara
    Calabrese, Massimo
    Tagliafico, Alberto Stefano
    DIAGNOSTICS, 2022, 12 (09)
  • [30] Value of One-View Breast Tomosynthesis Versus Two-View Mammography in Diagnostic Workup of Women With Clinical Signs and Symptoms and in Women Recalled From Screening
    Waldherr, Christian
    Cerny, Peter
    Altermatt, Hans J.
    Berclaz, Gilles
    Ciriolo, Michele
    Buser, Katharina
    Sonnenschein, Martin J.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2013, 200 (01) : 226 - 231