Automated Breast Ultrasound System for Breast Cancer Evaluation: Diagnostic Performance of the Two-View Scan Technique in Women with Small Breasts

被引:16
|
作者
Kwon, Bo Ra [1 ,2 ]
Chang, Jung Min [1 ]
Kim, Soo Yeon [1 ]
Lee, Su Hyun [1 ]
Kim, Soo-Yeon [1 ]
Lee, So Min [1 ]
Cho, Nariya [1 ]
Moon, Woo Kyung [1 ]
机构
[1] Seoul Natl Univ, Seoul Natl Univ Hosp, Dept Radiol, Coll Med, Seoul, South Korea
[2] Seoul Natl Univ Hosp, Dept Radiol, Gangnam Ctr, Healthcare Syst, Seoul, South Korea
关键词
Breast cancer; Automated breast ultrasound system; Scan technique; Diagnostic performance; Small breasts; HAND-HELD ULTRASOUND; B-MODE ULTRASOUND; VOLUME SCANNER; LESION DETECTION; MAMMOGRAPHY; HHUS; DIFFERENTIATION; RISK; US;
D O I
10.3348/kjr.2019.0275
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To comparatively evaluate the scan coverage and diagnostic performance of the two-view scan technique (2-VST) of the automated breast ultrasound system (ABUS) versus the conventional three-view scan technique (3-VST) in women with small breasts. Materials and Methods: Between March 2016 and May 2017, 136 asymptomatic women with small breasts (bra cup size A) suitable for 2-VST were enrolled. Subsequently, 272 breasts were subjected to bilateral whole-breast ultrasound examinations using ABUS and the hand-held ultrasound system (HHUS). During ABUS image acquisition, one breast was scanned with 2-VST, while the other breast was scanned with 3-VST. In each breast, the breast coverage and visibility of the HHUS detected lesions on ABUS were assessed. The sensitivity and specificity of ABUS were compared between 2-VST and 3-VST. Results: Among 136 breasts, eight cases of breast cancer were detected by 2-VST, and 10 cases of breast cancer were detected by 3-VST. The breast coverage was satisfactory in 94.1% and 91.9% of cases under 2-VST and 3-VST, respectively (p = 0.318). All HHUS-detected lesions were visible on the ABUS images regardless of the scan technique. The sensitivities and specificities were similar between 2-VST and 3-VST (100% [8/8] vs. 100% [10/10], and 97.7% [125/128] vs. 95.2% [120/126], respectively), with no significant difference (p > 0.05). Conclusion: 2-VST of ABUS achieved comparable scan coverage and diagnostic performance to that of conventional 3-VST in women with small breasts.
引用
收藏
页码:25 / 32
页数:8
相关论文
共 50 条
  • [1] Diagnostic performance of automated breast ultrasound and handheld ultrasound in women with dense breasts
    Jia, Mengmeng
    Lin, Xi
    Zhou, Xiang
    Yan, Huijiao
    Chen, Yaqing
    Liu, Peifang
    Bao, Lingyun
    Li, Anhua
    Basu, Partha
    Qiao, Youlin
    Sankaranarayanan, Rengaswamy
    BREAST CANCER RESEARCH AND TREATMENT, 2020, 181 (03) : 589 - 597
  • [2] Diagnostic performance of automated breast ultrasound and handheld ultrasound in women with dense breasts
    Mengmeng Jia
    Xi Lin
    Xiang Zhou
    Huijiao Yan
    Yaqing Chen
    Peifang Liu
    Lingyun Bao
    Anhua Li
    Partha Basu
    Youlin Qiao
    Rengaswamy Sankaranarayanan
    Breast Cancer Research and Treatment, 2020, 181 : 589 - 597
  • [3] Computerized detection of breast cancer on automated breast ultrasound imaging of women with dense breasts
    Drukker, Karen
    Sennett, Charlene A.
    Giger, Maryellen L.
    MEDICAL PHYSICS, 2014, 41 (01)
  • [4] Screening Breast Ultrasound Using Handheld or Automated Technique in Women with Dense Breasts
    Berg, Wendie A.
    Vourtsis, Athina
    JOURNAL OF BREAST IMAGING, 2019, 1 (04) : 283 - 296
  • [5] A Prospective Study of Automated Breast Ultrasound Screening of Women with Dense Breasts in a Digital Breast Tomosynthesis-based Practice
    Chough, Denise M.
    Berg, Wendie A.
    Bandos, Andriy, I
    Rathfon, Grace Y.
    Hakim, Christiane M.
    Lu, Amy H.
    Gizienski, Terri-Ann
    Ganott, Marie A.
    Gur, David
    JOURNAL OF BREAST IMAGING, 2020, 2 (02) : 125 - 133
  • [6] DIAGNOSTIC PERFORMANCE USING AUTOMATED BREAST ULTRASOUND SYSTEM FOR BREAST CANCER IN CHINESE WOMEN AGED 40 YEARS OR OLDER: A COMPARATIVE STUDY
    Zhang, Li
    Bao, Ling-Yun
    Tan, Yan-Juan
    Zhu, Luo-Qian
    Xu, Xiao-Jing
    Zhu, Qing-Qing
    Shan, Yan-Na
    Zhao, Jing
    Xie, Le-Si
    Liu, Jan
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2019, 45 (12) : 3137 - 3144
  • [7] Diagnostic Performance of Automated Breast Ultrasound in Differentiating Benign and Malignant Breast Masses in Asymptomatic Women: A Comparison Study With Handheld Ultrasound
    Niu, Lin
    Bao, Lingyun
    Zhu, Luoqian
    Tan, Yanjuan
    Xu, Xiaojing
    Shan, Yanna
    Liu, Jian
    Zhu, Qingqing
    Jiang, Chenxiang
    Shen, Yingzhao
    JOURNAL OF ULTRASOUND IN MEDICINE, 2019, 38 (11) : 2871 - 2880
  • [8] Utility and Diagnostic Performance of Automated Breast Ultrasound System in Evaluating Pure Non-Mass Enhancement on Breast Magnetic Resonance Imaging
    Kwon, Bo Ra
    Chang, Jung Min
    Kim, Soo Yeon
    Lee, Su Hyun
    Shin, Sung Ui
    Yi, Ann
    Cho, Nariya
    Moon, Woo Kyung
    KOREAN JOURNAL OF RADIOLOGY, 2020, 21 (11) : 1210 - 1219
  • [9] Diagnostic performance of coronal view in comparison with transverse view of three-dimensional automated breast ultrasound
    Suzuki, Megumi
    Nakayama, Ryohei
    Namba, Kiyoshi
    Kawami, Hiroyuki
    Nara, Mayumi
    Smathers, Ralph L.
    Nakamura, Seigo
    ACTA RADIOLOGICA, 2021, 62 (01) : 27 - 33
  • [10] Potential Usefulness a Coronal View using an Automated Breast Ultrasound System in Detecting Breast Lesions
    Suzuki, Megumi
    Nakayama, Ryohei
    Namba, Kiyoshi
    Kawami, Hiroyuki
    Nara, Mayumi
    Nakamura, Seigo
    EUROPEAN JOURNAL OF BREAST HEALTH, 2024, 20 (01) : 57 - 63