Non-Contact Heartbeat Detection Based on Ballistocardiogram Using UNet and Bidirectional Long Short-Term Memory

被引:26
作者
Mai, Yaozong [1 ,2 ,3 ]
Chen, Zizhao [1 ,2 ,3 ]
Yu, Baoxian [1 ,2 ,3 ]
Li, Ye [4 ]
Pang, Zhiqiang [5 ]
Han, Zhang [1 ,2 ,3 ]
机构
[1] South China Normal Univ, Sch Phys & Telecommun Engn, Guangzhou 510006, Peoples R China
[2] South China Normal Univ, Prov Res Ctr Cardiovasc Individual Med & Big Data, Guangzhou 510006, Peoples R China
[3] South China Normal Univ, Sch Elect & Informat Technol, Foshan 528200, Peoples R China
[4] Chinese Acad Sci, Shenzhen Inst Adv Technol, Shenzhen 518000, Peoples R China
[5] SENVIV Technol Co Ltd, Guangzhou 510006, Peoples R China
基金
中国国家自然科学基金;
关键词
Heart beat; Electrocardiography; Signal to noise ratio; Monitoring; Heart rate variability; Rhythm; Motion measurement; Ballistocardiogram; Bi-LSTM; heartbeat detection; UNet; NONINVASIVE MEASUREMENT; SYSTEM;
D O I
10.1109/JBHI.2022.3162396
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Benefiting from non-invasive sensing tech- nologies, heartbeat detection from ballistocardiogram (BCG) signals is of great significance for home-care applications, such as risk prediction of cardiovascular disease (CVD) and sleep staging, etc. In this paper, we propose an effective deep learning model for automatic heartbeat detection from BCG signals based on UNet and bidirectional long short-term memory (Bi-LSTM). The developed deep learning model provides an effective solution to the existing challenges in BCG-aided heartbeat detection, especially for BCG in low signal-to-noise ratio, in which the waveforms in BCG signals are irregular due to measured postures, rhythm and artifact motion. For validations, performance of the proposed detection is evaluated by BCG recordings from 43 subjects with different measured postures and heart rate ranges. The accuracy of the detected heartbeat intervals measured in different postures and signal qualities, in comparison with the R-R interval of ECG, is promising in terms of mean absolute error and mean relative error, respectively, which is superior to the state-of-the-art methods. Numerical results demonstrate that the proposed UNet-BiLSTM model performs robust to noise and perturbations (e.g. respiratory effort and artifact motion) in BCG signals, and provides a reliable solution to long term heart rate monitoring.
引用
收藏
页码:3720 / 3730
页数:11
相关论文
共 50 条
[21]   Driver Distraction Detection Using Bidirectional Long Short-Term Network Based on Multiscale Entropy of EEG [J].
Zuo, Xin ;
Zhang, Chi ;
Cong, Fengyu ;
Zhao, Jian ;
Hamalainen, Timo .
IEEE TRANSACTIONS ON INTELLIGENT TRANSPORTATION SYSTEMS, 2022, 23 (10) :19309-19322
[22]   Enhanced Deep Hierarchical Long Short-Term Memory and Bidirectional Long Short-Term Memory for Tamil Emotional Speech Recognition using Data Augmentation and Spatial Features [J].
Fernandes, Bennilo ;
Mannepalli, Kasiprasad .
PERTANIKA JOURNAL OF SCIENCE AND TECHNOLOGY, 2021, 29 (04) :2967-2992
[23]   DRGCN-BiLSTM: An Electrocardiogram Heartbeat Classification Using Dynamic Spatial-Temporal Graph Convolutional and Bidirectional Long-Short Term Memory Technique [J].
Sharma, Neenu ;
Joshi, Deepak .
IEEE TRANSACTIONS ON CONSUMER ELECTRONICS, 2025, 71 (01) :579-593
[24]   Multiclass Classification of Cardiac Rhythms on Short Single Lead ECG Recordings using Bidirectional Long Short-Term Memory Networks [J].
Altuve, Miguel ;
Hernandez, Fabio .
IEEE LATIN AMERICA TRANSACTIONS, 2021, 19 (07) :1207-1216
[25]   Short-term electricity demand forecasting via variational autoencoders and batch training-based bidirectional long short-term memory [J].
Moradzadeh, Arash ;
Moayyed, Hamed ;
Zare, Kazem ;
Mohammadi-Ivatloo, Behnam .
SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2022, 52
[26]   Self-Supervised, Non-Contact Heartbeat Detection Based on Ballistocardiograms Utilizing Physiological Information Guidance [J].
Jiao, Changzhe ;
Yang, Aoyu ;
Zhao, Hantao ;
Yi, Ruhan ;
Gou, Shuiping ;
Sha, Yu ;
Wen, Wanshun ;
Jiao, Licheng ;
Skubic, Marjorie .
IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2025, 29 (04) :2589-2602
[27]   A modified bidirectional long short-term memory neural network for rail vehicle suspension fault detection [J].
Chen, Yuejian ;
Niu, Gang ;
Li, Yifan ;
Li, Yongbo .
VEHICLE SYSTEM DYNAMICS, 2023, 61 (12) :3136-3160
[28]   Non-contact Detection of Human Heartbeat based on Measurement of Current Generated by Electrostatic Induction [J].
Kurita, Koichi .
2012 PROCEEDINGS OF SICE ANNUAL CONFERENCE (SICE), 2012, :988-992
[29]   Bidirectional Long Short-Term Memory for Sentiment Analysis of Chinese Product Reviews [J].
Zhang, Kai ;
Song, Wei ;
Liu, Lizhen ;
Zhao, Xinlei ;
Du, Chao .
PROCEEDINGS OF 2019 IEEE 9TH INTERNATIONAL CONFERENCE ON ELECTRONICS INFORMATION AND EMERGENCY COMMUNICATION (ICEIEC 2019), 2019, :665-668
[30]   Sleep staging by bidirectional long short-term memory convolution neural network [J].
Chen, Xueyan ;
He, Jie ;
Wu, Xiaoqiang ;
Yan, Wei ;
Wei, Wei .
FUTURE GENERATION COMPUTER SYSTEMS-THE INTERNATIONAL JOURNAL OF ESCIENCE, 2020, 109 :188-196