The ICON beamline - A facility for cold neutron imaging at SINQ

被引:219
作者
Kaestner, A. P. [1 ]
Hartmann, S. [1 ]
Kuehne, G. [2 ]
Frei, G. [2 ]
Gruenzweig, C. [1 ]
Josic, L. [1 ]
Schmid, F. [1 ]
Lehmann, E. H. [1 ]
机构
[1] Paul Scherrer Inst, Spallat Neutron Source Div, CH-5232 Villigen, Switzerland
[2] Paul Scherrer Inst, Radiat Protect Sch, CH-5232 Villigen, Switzerland
关键词
Cold neutrons; Imaging; Tomography; Dynamic imaging; Energy-selective imaging; Neutron interferometry; RADIOGRAPHY; RESOLUTION; SETUP; PSI;
D O I
10.1016/j.nima.2011.08.022
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The beamline for Imaging with COld Neutrons (ICON) at Swiss spallation neutron source (SINQ) at Paul Scherrer Institut has a flexible design to meet the requests from a wide user community. The current status of the beamline and its characteristics are described. The instrumentation includes three experimental positions from which two are equipped with digital camera based imaging detectors. Tomographic imaging is among the standard methods available at the beamline. Advanced methods such as energy-selective imaging and grating interferometry are available as instrument add-ons which are easily installed. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:387 / 393
页数:7
相关论文
共 29 条
  • [1] [Anonymous], LABV
  • [2] Artifacts in CT: Recognition and avoidance
    Barrett, JF
    Keat, N
    [J]. RADIOGRAPHICS, 2004, 24 (06) : 1679 - 1691
  • [3] Operation and development of the new spallation neutron source SINQ at the Paul Scherrer Institut
    Bauer, GS
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1998, 139 (1-4) : 65 - 71
  • [4] Blau B., 2009, Neutron News, V20, P5, DOI [10.1080/10448630903120387, DOI 10.1080/10448630903120387]
  • [5] In situ observation of the water distribution across a PEFC using high resolution neutron radiography
    Boillat, P.
    Kramer, D.
    Seyfang, B. C.
    Frei, G.
    Lehmann, E.
    Scherer, G. G.
    Wokaun, A.
    Ichikawa, Y.
    Tasaki, Y.
    Shinohara, K.
    [J]. ELECTROCHEMISTRY COMMUNICATIONS, 2008, 10 (04) : 546 - 550
  • [6] BOILLAT P, 2009, THESIS ETH ZURICH, DOI DOI 10.3929/ETHZ-A-005911827
  • [7] The complementary use of neutrons and X-rays for the non-destructive investigation of archaeological objects from Swiss collections
    Deschler-Erb, E
    Lehmann, EH
    Pernet, L
    Vontobel, P
    Hartmann, S
    [J]. ARCHAEOMETRY, 2004, 46 : 647 - 661
  • [8] SINQ - The spallation neutron source, a new research facility at PSI
    Fischer, WE
    [J]. PHYSICA B, 1997, 234 : 1202 - 1208
  • [9] The neutron micro-tomography setup at PSI and its use for research purposes and engineering applications
    Frei, G.
    Lehmann, E. H.
    Mannes, D.
    Boillat, P.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 605 (1-2) : 111 - 114
  • [10] Kinetics of hydrogen absorption and release in zirconium alloys during steam oxidation
    Grosse, M.
    Steinbrueck, M.
    Lehmann, E.
    Vontobel, P.