UK audit of target volume and organ at risk delineation and dose optimisation for cervix radiotherapy treatments

被引:3
作者
Cannon, Jennifer [1 ]
Bownes, Peter [2 ]
Mason, Joshua [3 ]
Cooper, Rachel [2 ]
机构
[1] James Cook Univ Hosp, Dept Med Phys, South Tees NHS Trust, Middlesbrough, Cleveland, England
[2] St James Univ Hosp, Leeds Teaching Hosp NHS Trust, Leeds Canc Ctr, Leeds, W Yorkshire, England
[3] Imperial Coll Healthcare NHS Trust, Dept Med Phys, London, England
关键词
GUIDED ADAPTIVE BRACHYTHERAPY; CANCER BRACHYTHERAPY; INTEROBSERVER VARIATION; UNCERTAINTIES; IMPACT; RECOMMENDATIONS; INTRACAVITARY; TERMS;
D O I
10.1259/bjr.20190897
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: Assessment of the extent of variation in delineations and dose optimisation performed at multiple UK centres as a result of interobserver variation and protocol differences. Methods: CT/MR images of 2 cervical cancer patients previously treated with external beam radiotherapy (EBRT) and Brachytherapy were distributed to 11 UK centres. Centres delineated structures and produced treatment plans following their local protocol. Organ at risk delineations were assessed dosimetrically through application of the original treatment plan and target volume delineations were assessed in terms of variation in absolute volume and length, width and height. Treatment plan variation was assessed across all centres and across centres that followed EMBRACE II. Treatment plans were assessed using total EQD(2) delivered and were compared to EMBRACE II dose aims. Variation in combined intracavitary/interstitial brachytherapy treatments was also assessed. Results: Brachytherapy target volume delineations contained variation due to differences in protocol used, window/level technique and differences in interpretations of grey zones. Planning target volume delineations were varied due to protocol differences and extended parametrial tissue inclusion. All centres met EMBRACE II plan aims for PTV V-95 and high-riskclinical target volume D-90 EQD(2), despite variation in prescription dose, fractionation and treatment technique. Conclusion: Brachytherapy target volume delineations are varied due to differences in contouring guidelines and protocols used. Planning target volume delineations are varied due to the uncertainties surrounding the extent of parametrial involvement. Dosimetric optimisation is sufficient across all centres to satisfy EMBRACE II planning aims despite significant variation in protocols used. Advances in knowledge: Previous multi-institutional audits of cervical cancer radiotherapy practices have been performed in Europe and the USA. This study is the first of its kind to be performed in the UK.
引用
收藏
页数:12
相关论文
共 26 条
[1]   Critical structure movement in cervix brachytherapy [J].
Anderson, Clare ;
Lowe, Gerry ;
Wills, Rachel ;
Inchley, David ;
Beenstock, Victoria ;
Bryant, Linda ;
Chapman, Caroline ;
Hoskin, Peter J. .
RADIOTHERAPY AND ONCOLOGY, 2013, 107 (01) :39-45
[2]   Importance of Technique, Target Selection, Contouring, Dose Prescription, and Dose-Planning in External Beam Radiation Therapy for Cervical Cancer: Evolution of Practice From EMBRACE-I to II [J].
Berger, Thomas ;
Seppenwoolde, Yvette ;
Poetter, Richard ;
Assenholt, Marianne Sanggaard ;
Lindegaard, Jacob C. ;
Nout, Remi A. ;
de Leeuw, Astrid ;
Jurgenliemk-Schulz, Ina ;
Tan, Li Tee ;
Georg, Dietmar ;
Kirisits, Christian ;
Dumas, Isabelle ;
Nesvacil, Nicole ;
Swamidas, Jamema ;
Hudej, Robert ;
Lowe, Gerry ;
Hellebust, Taran Paulsen ;
Menon, Geetha ;
Fokdal, Lars ;
Tanderup, Kari .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2019, 104 (04) :885-894
[3]   Inter-observer comparison of target delineation for MRI-assisted cervical cancer brachytherapy: Application of the GYN GEC-ESTRO recommendations [J].
Dimopoulos, Johannes C. A. ;
De Vos, Veronique ;
Berger, Daniel ;
Petric, Primoz ;
Dumas, Isabelle ;
Kirisits, Christian ;
Shenfield, Carey B. ;
Haie-Meder, Christine ;
Poetter, Richard .
RADIOTHERAPY AND ONCOLOGY, 2009, 91 (02) :166-172
[4]   Impact of delineation uncertainties on dose to organs at risk in CT-guided intracavitary brachytherapy [J].
Duane, Frances K. ;
Langan, Brian ;
Gillham, Charles ;
Walsh, Lorraine ;
Rangaswamy, Guhan ;
Lyons, Ciara ;
Dunne, Mary ;
Walker, Christopher ;
McArdle, Orla .
BRACHYTHERAPY, 2014, 13 (02) :210-218
[5]   Recommendations from Gynaecological (GYN) GEC-ESTRO Working Group* (I):: concepts and terms in 3D image based 3D treatment planning in cervix cancer brachytherapy with emphasis on MRI assessment of GTV and CTV [J].
Haie-Meder, C ;
Pötter, R ;
Van Limbergen, E ;
Briot, E ;
De Brabandere, M ;
Dimopoulos, J ;
Dumas, I ;
Hellebust, TP ;
Kirisits, C ;
Lang, SF ;
Muschitz, S ;
Nevinson, J ;
Nulens, A ;
Petrow, P ;
Wachter-Gerstner, N .
RADIOTHERAPY AND ONCOLOGY, 2005, 74 (03) :235-245
[6]   Dosimetric impact of interobserver variability in MRI-based delineation for cervical cancer brachytherapy [J].
Hellebust, Taran. Paulsen ;
Tanderup, Kari ;
Lervag, Christoffer ;
Fidarova, Elena ;
Berger, Daniel ;
Malinen, Eirik ;
Poetter, Richard ;
Petric, Primoz .
RADIOTHERAPY AND ONCOLOGY, 2013, 107 (01) :13-19
[7]   A novel algorithm for the morphometric assessment of radiotherapy treatment planning volumes [J].
Jena, R. ;
Kirkby, N. F. ;
Burton, K. E. ;
Hoole, A. C. F. ;
Tan, L. T. ;
Burnet, N. G. .
BRITISH JOURNAL OF RADIOLOGY, 2010, 83 (985) :44-51
[8]   The Vienna applicator for combined intracavitary and interstitial brachytherapy of cervical cancer:: Design, application, treatment planning, and dosimetric results [J].
Kirisits, C ;
Lang, S ;
Dimopoulos, J ;
Berger, D ;
Georg, D ;
Pötter, R .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 65 (02) :624-630
[9]   Quality assurance in MR image guided adaptive brachytherapy for cervical cancer: Final results of the EMBRACE study dummy run [J].
Kirisits, Christian ;
Federico, Mario ;
Nkiwane, Karen ;
Fidarova, Elena ;
Juergenliemk-Schulz, Ina ;
de Leeuw, Astrid ;
Lindegaard, Jacob ;
Poetter, Richard ;
Tanderup, Kari .
RADIOTHERAPY AND ONCOLOGY, 2015, 117 (03) :548-554
[10]   Assessment of radiation doses to the para-aortic, pelvic, and inguinal lymph nodes delivered by image-guided adaptive brachytherapy in locally advanced cervical cancer [J].
Mohamed, Sandy M. I. ;
Aagaard, Torben ;
Fokdal, Lars U. ;
Pedersen, Erik M. ;
Lindegaard, Jacob C. ;
Tanderup, Kari .
BRACHYTHERAPY, 2015, 14 (01) :56-61