Size-specific dose estimates (SSDEs) for computed tomography and influencing factors on it: a systematic review

被引:13
作者
Satharasinghe, D. M. [1 ,2 ]
Jeyasugiththan, J. [1 ]
Wanninayake, W. M. N. M. B. [2 ]
Pallewatte, A. S. [3 ]
机构
[1] Univ Colombo, Dept Nucl Sci, Colombo 03, Sri Lanka
[2] Horizon Campus, Malabe, Sri Lanka
[3] Natl Hosp Sri Lanka, Dept Radiol, Colombo, Sri Lanka
关键词
size-specific dose estimates; computed tomography; dose metrics; CT dose; SSDE; CTDI; RADIATION-EXPOSURE; CHEST;
D O I
10.1088/1361-6498/ac20b0
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The actual dose received during a computed tomography (CT) examination depends on both the patient size and the radiation output of the scanner. To represent the actual patient morphometry, a new radiation dose metric named size-specific dose estimates (SSDEs) was developed by the American Association of Physicists in Medicine in 2011. The purpose of this article is to review the SSDE concept and the factors influencing it. Moreover, the appropriate methodology of SSDE determination and the application of SSDE as a diagnostic reference-level quantity is critically analyzed based on the data available in the literature. It is expected that this review could potentially increase awareness among CT users of the effective utilization of SSDE as a tool to aid in the optimization of radiation dose in CT.
引用
收藏
页码:R108 / R124
页数:17
相关论文
共 31 条
[1]   Estimation of size-specific dose estimates (SSDE) for paediatric and adults patients based on a single slice [J].
Abuhaimed, Abdullah ;
Martin, Colin J. .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 74 :30-39
[2]   Correlation of size-dependent conversion factor and body-mass-index using size-specific dose estimates formalism in CT examinations [J].
Alikhani, Babak ;
Getzin, Tobias ;
Kaireit, Till Frederik ;
Ringe, Kristina Imeen ;
Jamali, Leila ;
Wacker, Frank ;
Werncke, Thomas ;
Raatschen, Hans-Juergen .
EUROPEAN JOURNAL OF RADIOLOGY, 2018, 100 :130-134
[3]   THE SIZE-SPECIFIC DOSE ESTIMATE (SSDE) FOR TRUNCATED COMPUTED TOMOGRAPHY IMAGES [J].
Anam, Choirul ;
Haryanto, Freddy ;
Widita, Rena ;
Arif, Idam ;
Dougherty, Geoff .
RADIATION PROTECTION DOSIMETRY, 2017, 175 (03) :313-320
[4]  
Boone JM., 2011, SIZE SPECIFIC DOSE E
[5]   Institutional computed tomography diagnostic reference levels based on water-equivalent diameter and size-specific dose estimates [J].
Boos, Johannes ;
Thomas, Christoph ;
Appel, Elisabeth ;
Klosterkemper, Yan ;
Schleich, Christoph ;
Aissa, Joel ;
Bethge, Oliver Th ;
Antoch, Gerald ;
Kroepil, Patric .
JOURNAL OF RADIOLOGICAL PROTECTION, 2018, 38 (02) :536-548
[6]   Investigation of American Association of Physicists in Medicine Report 204 Size-specific Dose Estimates for Pediatric CT Implementation [J].
Brady, Samuel L. ;
Kaufman, Robert A. .
RADIOLOGY, 2012, 265 (03) :832-840
[7]  
Dixon R., 2019, The Physics of CT Dosimetry CTDI and Beyond
[8]  
European Commission, 2018, EUROPEAN GUIDELINES
[9]   Radiation dose in chest CT: Assessment of size-specific dose estimates based on water-equivalent correction [J].
Gabusi, M. ;
Riccardi, L. ;
Aliberti, C. ;
Vio, S. ;
Paiusco, M. .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (02) :393-397
[10]   Diagnostic Reference Ranges for Pediatric Abdominal CT [J].
Goske, Marilyn J. ;
Strauss, Keith J. ;
Coombs, Laura P. ;
Mandel, Keith E. ;
Towbin, Alexander J. ;
Larson, David B. ;
Callahan, Michael J. ;
Darge, Kassa ;
Podberesky, Daniel J. ;
Frush, Donald P. ;
Westra, Sjirk J. ;
Prince, Jeffrey S. .
RADIOLOGY, 2013, 268 (01) :208-218