Modeling the effects of VOC/NOx emissions on ozone synthesis in the Cascadia airshed of the Pacific Northwest

被引:11
|
作者
Barna, M [1 ]
Lamb, B [1 ]
Westberg, H [1 ]
机构
[1] Washington State Univ, Dept Civil & Environm Engn, Lab Atmospher Res, Pullman, WA 99164 USA
来源
关键词
D O I
10.1080/10473289.2001.10464330
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A modeling system consisting of MM5, Calmet, and Calgrid was used to investigate the sensitivity of anthropogenic volatile organic compound (VOC) and oxides of nitrogen (NOx) reductions on ozone formation within the Cascadia airshed of the Pacific Northwest. An ozone episode that occurred on July 11-14, 1996, was evaluated. During this event, high ozone levels were recorded at monitors downwind of Seattle, WA, and Portland, OR, with one monitor exceeding the 1 hr/120 ppb National Ambient Air Quality Standard (at 148 ppb), and six monitors above the proposed 8 hr/80 ppb standard (at 82-130 ppb). For this particular case, significant emissions reductions, between 25 and 75%, would be required to decrease peak ozone concentrations to desired levels. Reductions in VOC emissions alone, or a combination of reduced VOC and NOx emissions, were generally found to be most effective; reducing NOx emissions alone resulted in increased ozone in the Seattle area. When only VOC emissions were curtailed, ozone reductions occurred in the immediate vicinity of densely populated areas, while NOx reductions resulted in more widespread ozone reductions.
引用
收藏
页码:1021 / 1034
页数:14
相关论文
共 50 条