Percutaneous Left Atrial Appendage Closure Using an Occluder Device: A Single Center Experience

被引:1
|
作者
Lugtu, Isaiah C. [1 ,2 ,3 ]
Cheng, Wen-Han [1 ,2 ,4 ,5 ]
Chang, Shih-Lin [1 ,2 ,4 ,5 ]
Liu, Shin-Huei [1 ,2 ,4 ,5 ]
Lo, Li-Wei [1 ,2 ,4 ,5 ]
Chen, Shih-Ann [1 ,2 ,4 ,5 ,6 ]
机构
[1] Taipei Vet Gen Hosp, Heart Rhythm Ctr, 201,Sec 2,Shih Pai Rd, Taipei 11217, Taiwan
[2] Taipei Vet Gen Hosp, Div Cardiol, 201,Sec 2,Shih Pai Rd, Taipei 11217, Taiwan
[3] Chinese Gen Hosp & Med Ctr, Heart Inst, Manila, Philippines
[4] Natl Yang Ming Chiao Tung Univ, Inst Clin Med, Taipei, Taiwan
[5] Natl Yang Ming Chiao Tung Univ, Cardiovasc Res Inst, Taipei, Taiwan
[6] Taichung Vet Gen Hosp, Cardiovasc Ctr, Taichung, Taiwan
关键词
Contrast leak; Left atrial appendage; Occluder device; STROKE PREVENTION; FIBRILLATION; ANTICOAGULATION; OCCLUSION; CONTRAINDICATIONS; THERAPY;
D O I
10.6515/ACS.202205_38(3).20211130A
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Left atrial appendage (LAA) is the main source of thrombus formation, and occlusion of this structure decreases the risk of stroke in patients with atrial fibrillation. Objectives: We aimed to describe the feasibility, safety and outcomes of percutaneous LAA closure using an occluder device, and to evaluate residual LAA contrast leak detected on computed tomography (CT) imaging in patients who underwent implantation in our institution. Methods: Consecutive patients of Taipei Veterans General Hospital who underwent percutaneous implantation of an LAA occluder (LAAO) were retrospectively collected and analyzed. Results: A total of 23 patients were included with a median age of 67 years (42-87) and median CHA(2)DS(2)-VASc score of 4 (1-7). The most frequent indication for intervention was bleeding while on oral anticoagulation treatment. After a mean follow-up of 31.17 +/- 25.10 months, successful device implantation was achieved in 95.7% of the patients. There was no occurrence of death, stroke, device embolization, acute ST elevation myocardial infarction, major bleeding requiring invasive treatment or blood transfusion, inguinal hematoma or major bleeding related to antiplatelet therapy. One patient had cardiac tamponade, 1 had intra-procedural thrombus formation, 1 had impingement of mitral valve leaflet, and 1 had device-related thrombosis. Of 12 patients who underwent CT post-implantation, 6 had residual contrast leak into the LAA, one third of those who had peri-device leak. Conclusions: Percutaneous implantation of an LAAO appeared to be feasible with a low risk of major complications.
引用
收藏
页码:352 / 361
页数:10
相关论文
共 50 条
  • [21] Percutaneous Left Atrial Appendage Closure Procedural Techniques and Outcomes
    Saw, Jacqueline
    Lempereur, Mathieu
    JACC-CARDIOVASCULAR INTERVENTIONS, 2014, 7 (11) : 1205 - 1220
  • [22] Left Atrial Appendage Closure: Initial Experience With the Ultraseal Device
    Regueiro, Ander
    Bernier, Mathieu
    O'Hara, Gilles
    O'Connor, Kim
    Paradis, Jean-Michel
    Beaudoin, Jonathan
    Rodriguez-Gabella, Tania
    Champagne, Jean
    Rodes-Cabau, Josep
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2017, 90 (05) : 817 - 823
  • [23] Initial experience with post Lariat left atrial appendage leak closure with Amplatzer septal occluder device and repeat Lariat application
    Pillai, Anand M.
    Kanmanthareddy, Arun
    Earnest, Matthew
    Reddy, Madhu
    Ferrell, Ryan
    Nath, Jayanth
    Pillarisetti, Jayasree
    Vallakati, Ajay
    Lakkireddy, Dhanunjaya
    HEART RHYTHM, 2014, 11 (11) : 1877 - 1883
  • [24] Percutaneous Epicardial Left Atrial Appendage Closure: Intermediate-Term Results
    Bruce, Charles J.
    Stanton, Christopher M.
    Asirvatham, Samuel J.
    Danielsen, Andrew J.
    Johnson, Susan B.
    Packer, Douglas L.
    Friedman, Paul A.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2011, 22 (01) : 64 - 70
  • [25] Pericardial effusion following percutaneous left atrial appendage closure using the LAmbre device
    Yu, Yibo
    Chu, Huimin
    Wang, Binhao
    He, Bin
    Fu, Guohua
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2023, 10
  • [26] Direct current cardioversion practices following percutaneous left atrial appendage closure
    Bhuta, Sapan
    Shaaban, Adnan
    Binda, Nkongho C.
    Antaki, James
    Augostini, Ralph S.
    Kalbfleisch, Steven J.
    Savona, Salvatore J.
    Okabe, Toshimasa
    Houmsse, Mahmoud
    Afzal, Muhammad R.
    Daoud, Emile G.
    Hummel, John D.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2023, 34 (08) : 1698 - 1705
  • [27] Percutaneous Left Atrial Appendage Closure With LACBES® Occluder - A Preclinical Feasibility Study
    Tang, Xuechao
    Zhang, Zhigang
    Wang, Feiyu
    Bai, Yuan
    Xu, Xudong
    Huang, Xinmiao
    Zhao, Xianxian
    Gong, Shanshi
    Qin, Yongwen
    CIRCULATION JOURNAL, 2018, 82 (01) : 87 - 92
  • [28] Percutaneous left atrial appendage exclusion
    Juliard, Jean-Michel
    Brochet, Eric
    Aubry, Pierre
    Himbert, Dominique
    Depoix, Jean-Paul
    Ou, Phalla
    Vahanian, Alec
    SANG THROMBOSE VAISSEAUX, 2013, 25 (06): : 329 - 337
  • [29] Learning Curve Assessment for Percutaneous Left Atrial Appendage Closure With the WATCHMAN Occluder
    Ledwoch, Jakob
    Krollmann, Christine
    Staubach, Stephan
    Hug, Martin
    Strohm, Henning
    Mudra, Harald
    JOURNAL OF INTERVENTIONAL CARDIOLOGY, 2016, 29 (04) : 393 - 399
  • [30] Left Atrial Appendage Closure with the LAmbre Device - Initial Multicentre Experience in Brazil
    Chamie, Francisco
    Guerios, Enio
    Peralta e Silva, Daniel
    Fuks, Valerio
    Torres, Romulo
    ARQUIVOS BRASILEIROS DE CARDIOLOGIA, 2022, 119 (01) : 48 - 55