Precise 3D/2D calibration between a RGB-D sensor and a C-arm fluoroscope

被引:0
|
作者
Wang, Xiang [1 ,2 ]
Habert, Severine [2 ]
Ma, Meng [2 ]
Huang, Chun-Hao [2 ]
Fallavollita, Pascal [2 ]
Navab, Nassir [2 ,3 ]
机构
[1] Beihang Univ, Sch Automat Sci & Elect Engn, Xueyuan Rd 37, Beijing, Peoples R China
[2] Tech Univ Munich, Chair Comp Aided Med Procedures, Boltzmannstr 3, D-85748 Garching, Germany
[3] Johns Hopkins Univ, Baltimore, MD USA
关键词
3D/2D calibration; C-arm fluoroscope; RGB-D sensor; Calibration phantom; INTRAOPERATIVE AUGMENTED REALITY; DISTORTION CORRECTION; CAMERA CALIBRATION; ACCURACY; DEPTH;
D O I
10.1007/s11548-015-1347-2
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Calibration and registration are the first steps for augmented reality and mixed reality applications. In the medical field, the calibration between an RGB-D camera and a C-arm fluoroscope is a new topic which introduces challenges. A convenient and efficient calibration phantom is designed by combining the traditional calibration object of X-ray images with a checkerboard plane. After the localization of the 2D marker points in the X-ray images and the corresponding 3D points from the RGB-D images, we calculate the projection matrix from the RGB-D sensor coordinates to the X-ray, instead of estimating the extrinsic and intrinsic parameters simultaneously. In order to evaluate the effect of every step of our calibration process, we performed five experiments by combining different steps leading to the calibration. We also compared our calibration method to Tsai's method to evaluate the advancement of our solution. At last, we simulated the process of estimating the rotation movement of the RGB-D camera using MATLAB and demonstrate that calculating the projection matrix can reduce the angle error of the rotation. A RMS reprojection error of 0.5 mm is achieved using our calibration method which is promising for surgical applications. Our calibration method is more accurate when compared to Tsai's method. Lastly, the simulation result shows that using a projection matrix has a lower error than using intrinsic and extrinsic parameters in the rotation estimation. We designed and evaluated a 3D/2D calibration method for the combination of a RGB-D camera and a C-arm fluoroscope.
引用
收藏
页码:1385 / 1395
页数:11
相关论文
共 50 条
  • [31] Real-time tracking of 3D elastic objects with an RGB-D sensor
    Petit, Antoine
    Lippiello, Vincenzo
    Siciliano, Bruno
    2015 IEEE/RSJ INTERNATIONAL CONFERENCE ON INTELLIGENT ROBOTS AND SYSTEMS (IROS), 2015, : 3914 - 3921
  • [32] Estimating the 3D center point of an object with Kinect sensor RGB-D images
    Armenio, Gustavo Fardo
    Fabro, Joao Alberto
    Tognella, Renzo de Rosa
    Conter, Felipe Pierre
    de Oliveira, Marlon Vaz
    Silva, Everson de Souza
    2023 LATIN AMERICAN ROBOTICS SYMPOSIUM, LARS, 2023 BRAZILIAN SYMPOSIUM ON ROBOTICS, SBR, AND 2023 WORKSHOP ON ROBOTICS IN EDUCATION, WRE, 2023, : 478 - 483
  • [33] Depth-Scale Method in 3D Registration of RGB-D Sensor Outputs
    Bozkurt, Ismail
    Ozden, Kemal Egemen
    PROCEEDINGS OF THE 2014 9TH INTERNATIONAL CONFERENCE ON COMPUTER VISION THEORY AND APPLICATIONS (VISAPP), VOL 1, 2014, : 470 - 475
  • [34] Joint calibration of 2D and 3D vision integrated sensor system
    Li, Lin
    Zhang, Xu
    Tu, Dawei
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2012, 33 (11): : 2473 - 2479
  • [35] 3D object detection: Learning 3D bounding boxes from scaled down 2D bounding boxes in RGB-D images
    Rahman, Mohammad Muntasir
    Tan, Yanhao
    Xue, Jian
    Shao, Ling
    Lu, Ke
    INFORMATION SCIENCES, 2019, 476 : 147 - 158
  • [36] A Comparison of 2D and 3D Convolutional Neural Networks for Hand Gesture Recognition from RGB-D Data
    Kurmanji, Meghdad
    Ghaderi, Foad
    2019 27TH IRANIAN CONFERENCE ON ELECTRICAL ENGINEERING (ICEE 2019), 2019, : 2022 - 2027
  • [37] Intraoperative 3D imaging with a standard c-arm
    Tita, R.
    Lueth, T. C.
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2007, 2 : S206 - S208
  • [38] RGB-D Multi-View System Calibration for Full 3D Scene Reconstruction
    Afzal, Hassan
    Aouada, Djamila
    Fofi, David
    Mirbach, Bruno
    Ottersten, Bjoern
    2014 22ND INTERNATIONAL CONFERENCE ON PATTERN RECOGNITION (ICPR), 2014, : 2459 - 2464
  • [39] Multidimensional Precision Hybrid Mobile 2D/3D C-Arm Assisted Biopsy of Peripheral Lung Nodules
    Avasarala, Sameer K.
    Machuzak, Michael S.
    Gildea, Thomas R.
    JOURNAL OF BRONCHOLOGY & INTERVENTIONAL PULMONOLOGY, 2020, 27 (02) : 153 - 155
  • [40] Accuracy evaluation of a correction table for calibration of an RGB-D sensor
    Ishii M.
    Fujino S.
    International Journal of the Society of Material Engineering for Resources, 2018, 23 (01) : 68 - 73