Dual-label time-resolved fluoroimmunoassay for simultaneous measurement of human epidermal growth factor receptor 2 and human epididymis protein 4 in serum

被引:3
|
作者
Zhang, Yi [1 ]
Wang, Ke [2 ]
Zhao, Ying [3 ]
Fan, Jun [1 ]
Han, Tingting [1 ]
Si, Yu-an [2 ]
Zhou, Bin [1 ,5 ]
Zhang, Jue [1 ]
Hu, Zhigang [4 ]
Xie, Minhao [1 ,5 ]
机构
[1] Jiangsu Inst Nucl Med, NHC Key Lab Nucl Med, Jiangsu Key Lab Mol Nucl Med, 20 Qianrong Rd, Wuxi 214063, Jiangsu, Peoples R China
[2] Jiangyin Peoples Hosp, Dept Clin Lab, 163 Shoushan Rd, Jiangyin 214400, Jiangsu, Peoples R China
[3] Jiangsu Inst Nucl Med, Dept Gynecol, Jiangyuan Hosp, 18 Qianrong Rd, Wuxi 214063, Jiangsu, Peoples R China
[4] Nanjing Med Univ, Wuxi Peoples Hosp, Dept Clin Lab, Wuxi Childrens Hosp, 299 Qingyang Rd, Wuxi 214023, Jiangsu, Peoples R China
[5] Nanjing Med Univ, Sch Pharm, Dept Radiopharmaceut, 109 Longmian Ave, Nanjing 211166, Jiangsu, Peoples R China
关键词
Human epidermal growth factor receptor 2; Human epididymis protein 4; Time-resolved fluoroimmunoassay; Gynecological cancer; Simultaneous detection; BREAST-CANCER; OVARIAN; DIAGNOSIS; HE-4; STATISTICS; HER2;
D O I
10.1186/s40543-019-0201-5
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this study, a novel dual-label time-resolved fluoroimmunoassay (TRFIA) is described for simultaneous quantification of human epidermal growth factor receptor 2 (HER-2) and human epididymis protein 4 (HE4) in serum to screen gynecologic cancers. A double-antibody sandwich TRFIA was introduced with europium and samarium chelates to simultaneously detect the concentrations of HER-2 and HE4. Under optimal conditions, the proposed method exhibited wide linear ranges for HER-2 of 0.07-500 ng ml(-1) and for HE4 of 0.32-1000 pmol l(-1) with the average coefficient of variation below 10%. The specificity was satisfied through determining the other common tumor markers. The recovery rates were 94.5% and 96.6% on average for HER-2 and HE4, respectively. Good correlations were observed in clinical samples between developed method and commercial chemiluminescence immunoassay kits. The results demonstrated that dual-label TRFIA for HER-2 and HE4 was rapid and precise, and therefore could have a promising use in large sample detection for gynecological cancer screening.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Dual-label time-resolved fluoroimmunoassay for simultaneous measurement of human epidermal growth factor receptor 2 and human epididymis protein 4 in serum
    Yi Zhang
    Ke Wang
    Ying Zhao
    Jun Fan
    Tingting Han
    Yu-an Si
    Bin Zhou
    Jue Zhang
    Zhigang Hu
    Minhao Xie
    Journal of Analytical Science and Technology, 11
  • [2] Dual-label time-resolved fluoroimmunoassay for simultaneous detection of aflatoxin B1 and ochratoxin A
    Huang, Biao
    Xiao, Hualong
    Zhang, Jue
    Zhang, Lianfen
    Yang, Hailin
    Zhang, Yi
    Jin, Jian
    ARCHIVES OF TOXICOLOGY, 2009, 83 (06) : 619 - 624
  • [3] Dual-label time-resolved fluoroimmunoassay for simultaneous detection of aflatoxin B1 and ochratoxin A
    Biao Huang
    Hualong Xiao
    Jue Zhang
    Lianfen Zhang
    Hailin Yang
    Yi Zhang
    Jian Jin
    Archives of Toxicology, 2009, 83 : 619 - 624
  • [4] Simultaneous determination of the cytokeratin 19 fragment and carcinoembryonic antigen in human serum by magnetic nanoparticle-based dual-label time-resolved fluoroimmunoassay
    Lin, Guanfeng
    Zhao, Hui
    Liu, Tiancai
    Hou, Jingyuan
    Ren, Zhiqi
    Huang, Wenhua
    Dong, Wenqi
    Wu, Yingsong
    RSC ADVANCES, 2014, 4 (98): : 55229 - 55236
  • [5] A competitive dual-label time-resolved fluoroimmunoassay for the simultaneous detection of chlortetracycline and doxycycline in animal edible tissues
    Le, Tao
    Yi, ShanHong
    Wei, Shu
    Liu, Jin
    FOOD AND AGRICULTURAL IMMUNOLOGY, 2015, 26 (06) : 804 - 812
  • [6] A DUAL-LABEL TIME-RESOLVED FLUORESCENCE IMMUNOASSAY FOR THE SIMULTANEOUS DETERMINATION OF β-HUMAN CHORIONIC GONADOTROPIN AND PROGESTERONE
    Sun, Wenqiao
    Ren, Shoulei
    Yuan, Guangwen
    Wang, Yan
    Li, Laiqing
    Zhang, Licheng
    ANALYTICAL LETTERS, 2014, 47 (18) : 2900 - 2908
  • [7] Simultaneous Detection of Prolactin and Growth Hormone Using a Dual-label Time-resolved Fluorescence Immunoassay
    Zhong, Shuhai
    Liang, Huankun
    Peng, Fenglan
    Lu, Yanhong
    Liu, Tiancai
    Kulchytski, Uladzimir
    Dong, Wenqi
    JOURNAL OF FLUORESCENCE, 2024, 35 (3) : 1417 - 1422
  • [8] Eu3+/Sm3+ dual-label time-resolved fluoroimmunoassay for measurement of hepatitis C virus antibodies
    Yang, Xue
    Ye, Yan
    Wang, Tingting
    Li, Mei
    Yu, Lei
    Xia, Min
    Qian, Jun
    Hu, Zhigang
    JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2019, 33 (02)
  • [9] Development of an improved time-resolved fluoroimmunoassay for simultaneous quantification of C-peptide and insulin in human serum
    Liu, Tian-Cai
    Chen, Mei-Jun
    Ren, Zhi-Qi
    Hou, Jing-Yuan
    Lin, Guan-Feng
    Wu, Ying-Song
    CLINICAL BIOCHEMISTRY, 2014, 47 (06) : 439 - 444
  • [10] Simultaneous quantitation of carbohydrate antigen 125 and carcinoembryonic antigen in human serum via time-resolved fluoroimmunoassay
    Huang, Zhen
    Zhai, Xiang-Ming
    Wang, Hao
    Deng, Qiao-Ting
    Li, Kun
    Liu, Bi-Sen
    Wang, Gang
    Liu, Tian-Cai
    CLINICA CHIMICA ACTA, 2018, 483 : 222 - 226