Generalized DOE analysis of radiographic and dual-energy imaging using flat-panel detectors

被引:116
作者
Richard, S [1 ]
Siewerdsen, JH [1 ]
Jaffray, DA [1 ]
Moseley, DJ [1 ]
Bakhtiar, B [1 ]
机构
[1] Univ Toronto, Dept Med Biophys, Toronto, ON M5G 2M9, Canada
关键词
dual-energy imaging; anatomical noise; flat-panel detectors; detective quantum efficiency; noise-power spectrum; detectability index; generalized DQE; thoracic imaging; lung nodules; imaging performance;
D O I
10.1118/1.1901203
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Analysis of detective quantum efficiency (DQE) is an important component of the investigation of imaging performance for flat-panel detectors (FPDs). Conventional descriptions of DQE are limited, however, in that they take no account of anatomical noise (i.e., image fluctuations caused by overlying anatomy), even though such noise can be the most significant limitation to detectability, often. outweighing quantum or electronic noise. We incorporate anatomical noise in experimental and theoretical descriptions of the "generalized DQE" by including a spatial-frequency-dependent noise-power term, S-B, corresponding to background anatomical fluctuations. Cascaded systems analysis (CSA) of the generalized DQE reveals tradeoffs between anatomical noise and the factors that govern quantum noise. We extend such analysis to dual-energy (DE) imaging, in which the overlying anatomical structure is selectively removed in image reconstructions by combining projections acquired at low and high kVp. The effectiveness of DE imaging in removing anatomical noise is quantified by measurement Of S-B in an anthropomorphic phantom. Combining the generalized DQE with an idealized task function to yield the detectability index, we show that anatomical noise dramatically influences task-based performance, system design, and optimization. For the case of radiography, the analysis resolves a fundamental and illustrative quandary: The effect of kVp on imaging performance, which is poorly described by conventional DQE analysis but is clarified by consideration of the generalized DQE. For the case of DE imaging, extension of a generalized CSA methodology reveals a potentially powerful guide to system optimization through the optimal selection of the tissue cancellation parameter. Generalized task-based analysis for DE imaging shows an improvement in the detectability index by more than a factor of 2 compared to conventional radiography for idealized detection tasks. (c) 2005 American Association of Physicists in Medicine.
引用
收藏
页码:1397 / 1413
页数:17
相关论文
共 71 条
[61]   Optimization of x-ray imaging geometry (with specific application to flat-panel cone-beam computed tomography) [J].
Siewerdsen, JH ;
Jaffray, DA .
MEDICAL PHYSICS, 2000, 27 (08) :1903-1914
[62]  
SIEWERDSEN JH, 2005, S SPIE VIS DISPL IM, V5745, P198
[63]  
Sone S, 1996, Radiat Med, V14, P53
[64]  
Storm E., 1970, Nucl. Data Tables, V7, P565, DOI [10.1016/S0092-640X(70)80017-1, DOI 10.1016/S0092-640X(70)80017-1]
[65]   Solid-state fluoroscopic imager for high-resolution angiography: Parallel-cascaded linear systems analysis [J].
Vedantham, S ;
Karellas, A ;
Suryanarayanan, S .
MEDICAL PHYSICS, 2004, 31 (05) :1258-1268
[66]   Full breast digital mammography with an amorphous silicon-based flat panel detector: Physical characteristics of a clinical prototype [J].
Vedantham, S ;
Karellas, A ;
Suryanarayanan, S ;
Albagli, D ;
Han, S ;
Tkaczyk, EJ ;
Landberg, CE ;
Opsahl-Ong, B ;
Granfors, PR ;
Levis, I ;
D'Orsi, CJ ;
Hendrick, RE .
MEDICAL PHYSICS, 2000, 27 (03) :558-567
[67]  
VYBORNEY CJ, 1976, THESIS U CHICAGO
[68]   Parallel cascades: New ways to describe noise transfer in medical imaging systems [J].
Yao, J ;
Cunningham, IA .
MEDICAL PHYSICS, 2001, 28 (10) :2020-2038
[69]  
YORKSTON J, 1994, P SOC PHOTO-OPT INS, V2163, P141, DOI 10.1117/12.174249
[70]   Digital radiology using active matrix readout of amorphous selenium: Theoretical analysis of detective quantum efficiency [J].
Zhao, W ;
Rowlands, JA .
MEDICAL PHYSICS, 1997, 24 (12) :1819-1833