Anterior chamber angle width, central vault and intraocular pressure changes after 12 months of Visian collamer lens implantation

被引:16
作者
Sanchez-Gonzalez, Jose-Maria [1 ,2 ]
Alonso-Aliste, Federico [2 ]
Perea-Pena, Gracia [1 ]
Rachwani-Anil, Rahul [3 ]
Marquez-de-Aracena-del-Cid, Rafael [4 ]
Rocha-de-Lossada, Carlos [3 ,5 ]
机构
[1] Univ Seville, Dept Condensed Matter Phys, Opt Area, Reina Mercedes St, Seville, Spain
[2] Tecnolaser Clin Vis, Dept Ophthalmol, Seville, Spain
[3] Reg Univ Hosp Malaga, Dept Ophthalmol, Malaga, Spain
[4] Univ Seville, Dept Surg, Ophthalmol Area, Seville, Spain
[5] Clin Barcelona Hosp, Dept Ophthalmol, Barcelona, Spain
关键词
Implantable collamer lens; Anterior chamber angle width; Central vault; Intraocular phakic lens; Posterior chamber phakic lens; Intraocular pressure; CENTRAL HOLE;
D O I
10.1007/s10792-020-01381-w
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose To evaluate 1-year changes of vault, anterior chamber angle width (ACAW) and intraocular pressure (IOP) after the implantation of implantable collamer lens (ICL) V4c in high myopic patients. Methods Sixty ICL V4c implantation surgeries were included. Patients underwent surgery between January 2014 and June 2017 at Ophthalmology Center Tecnolaser Clinic Vision (R), Seville, Spain. All patients had a 12-month follow-up. A preoperative spherical equivalent between - 4.00 and - 15.00 D was established as inclusion criterion. ACAW and vault were measured with Pentacam single rotation Scheimpflug camera (Oculus Optikgerate GmbH, Wetzlar, Germany). IOP was measured with CORVIS ST (Oculus Optikgerate GmbH, Wetzlar, Germany). Results One-day vault was 553.17 +/- 169.80 [268-975] mu m; 12-month vault was 515.67 +/- 176.46 [169-950] mu m (p < 0.01). Preoperative ACAW was 36.85 degrees +/- 4.60 degrees [26.7 degrees-46.8 degrees]; postoperative ACAW was 25.98 degrees +/- 3.85 degrees [16.4 degrees-32.6 degrees] (p < 0.01). Preoperative IOP was 15.37 +/- 1.58 [12.0-18.3] mmHg, postoperative IOP was 15.61 +/- 1.60 [12.0-19.0] mm Hg (p = 0.35). Conclusions ICL V4c lens experienced a progressive reduction of vault after 12-month follow-up. ACAW decrease was significant between preoperative and postoperative values. We propose to include a minimum preoperative ACAW and an IOP correction factor for lens size.
引用
收藏
页码:2047 / 2053
页数:7
相关论文
共 26 条
[1]   Collagen copolymer toric phakic intraocular lens for myopic astigmatism: One-year follow-up [J].
Alfonso, Jose F. ;
Lisa, Carlos ;
Alfonso-Bartolozzi, Belen ;
Perez-Vives, Cari ;
Montes-Mico, Robert .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2014, 40 (07) :1155-1162
[2]   Clinical outcomes after implantation of a posterior chamber collagen copolymer phakic intraocular lens with a central hole for myopic correction [J].
Alfonso, Jose F. ;
Lisa, Carlos ;
Fernandez-Vega Cueto, Luis ;
Belda-Salmeron, Lurdes ;
Madrid-Costa, David ;
Montes-Mico, Robert .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2013, 39 (06) :915-921
[3]   Long-term evaluation of the central vault after phakic CollamerA® lens (ICL) implantation using OCT [J].
Alfonso, Jose F. ;
Fernandez-Vega, L. ;
Lisa, C. ;
Fernandes, P. ;
Gonzalez-Meijome, J. ;
Montes-Mico, R. .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2012, 250 (12) :1807-1812
[4]   Central vault after phakic intraocular lens implantation: Correlation with anterior chamber depth, white-to-white distance, spherical equivalent, and patient age [J].
Alfonso, Jose F. ;
Fernandez-Vega, Luis ;
Lisa, Carlos ;
Fernandes, Paulo ;
Jorge, Jorge ;
Montes Mico, Robert .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (01) :46-53
[5]   Posterior chamber collagen copolymer phakic intraocular lenses to correct myopia: Five-year follow-up [J].
Alfonso, Jose F. ;
Baamonde, Begona ;
Fernandez-Vega, Luis ;
Fernandes, Paulo ;
Gonzalez-Meijome, Jose M. ;
Montes-Mico, Robert .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (05) :873-880
[6]   Presumed Furosemide-associated Bilateral Angle-Closure Glaucoma [J].
Boundaoui, Oussama N. ;
Woodruff, Todd E. .
JOURNAL OF GLAUCOMA, 2016, 25 (08) :E748-E750
[7]   Comparison of early changes in and factors affecting vault following posterior chamber phakic Implantable Collamer Lens implantation without and with a central hole (ICL V4 and ICL V4c) [J].
Chen, Xun ;
Miao, Huamao ;
Naidu, Rajeev Krishnan ;
Wang, Xiaoying ;
Zhou, Xingtao .
BMC OPHTHALMOLOGY, 2016, 16
[8]   Changes in Iridocorneal Angle Structure and Trabecular Pigmentation With STAAR Implantable Collamer Lens During 2 Years [J].
Chung, Tae-Young ;
Park, Sung Chul ;
Lee, Myoung Ok ;
Ahn, Kyeon ;
Chung, Eui-Sang .
JOURNAL OF REFRACTIVE SURGERY, 2009, 25 (03) :251-258
[9]   Long-term follow-up of persistent low vault after implantable collamer lens exchange [J].
Cordoba, Andrea ;
Graue-Hernandez, Enrique O. ;
Gomez-Bastar, Arturo ;
Navas, Alejandro .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (04) :519-522
[10]   Anterior Chamber Angle Evaluation following Phakic Posterior Chamber Collamer Lens with CentraFLOW and Its Correlation with ICL Vault and Intraocular Pressure [J].
Eissa, Sherif A. ;
Sadek, Sherin H. ;
El-Deeb, Mohamed W. A. .
JOURNAL OF OPHTHALMOLOGY, 2016, 2016