Randomized trial of rapamycin- and paclitaxel-eluting stents with identical biodegradable polymeric coating and design

被引:29
|
作者
Wessely, Rainer
Kastrati, Adnan
Mehilli, Julinda
Dibra, Alban
Pache, Juergen
Schoemig, Albert
机构
[1] Univ Technol, Klinikum Rechts Isar, Deutsch Herzzentrum, D-80696 Munich, Germany
[2] Univ Technol, Klinikum Rechts Isar, Med Klin 1, D-80696 Munich, Germany
关键词
drug-eluting stents; rapamycin; sirolimus; paclitaxel; restenosis; coronary artery disease;
D O I
10.1093/eurheartj/ehm425
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims This prospective, randomized study sought to directly compare the performance of paclitaxel and rapamycin on an otherwise identical, polymer-coated drug-eluting stent (DES) platform. Methods and results Stents with identical design and biodegradable polymeric coating that elute either rapamycin or paclitaxel over a 2 months time period were utilized. In this pilot trial that included 91 patients, both stent platforms proved safe with no case of death, Q-wave myocardial infarction or stent thrombosis within a 9 months follow-up period. Late-lumen loss was markedly greater in the paclitaxel-eluting stent group compared with the rapamycin-eluting stent group (0.96 +/- 0.75 vs. 0.33 +/- 0.46 mm, P < 0.0001). Likewise, the rate of angiographic restenosis was higher in the paclitaxeleluting stent group compared with the rapamycin-eluting stent group [39.0 vs. 12.2%; relative risk (RR) 3.20 (95% confidence interval, 1.29-7.92), P = 0.005]. Concomitantly, the need for target lesion revascularization was higher in the paclitaxel-eluting stent group compared with the rapamycin-eluting stent group [26.7 vs. 8.7%; RR 3.07 (1.07-8.80), P = 0.02]. Conclusion The results of this clinical trial that is the first to directly compare the performance of paclitaxel and rapamycin on a DES platform otherwise identical in design and polymeric coating imply that rapamycin is more effective for the prevention of coronary restenosis on a DES platform with mid-term drug release and less dependent on release kinetics than paclitaxel. Thus, to ensure efficacy, drug release from a paclitaxel-coating stent platform must be prolonged and well controlled to achieve results that are comparable with the FDA-approved paclitaxel-eluting stent platform.
引用
收藏
页码:2720 / 2725
页数:6
相关论文
共 50 条
  • [1] Comparison of the efficacy and safety of paclitaxel-eluting coroflex please stents and paclitaxel-eluting stents in patients with coronary artery disease: A randomized PIPA trial
    Kim, Hyun-Sook
    Park, Seung-Jung
    Park, Duk-Woo
    Park, Seong-Wook
    Cheong, Sang-Sig
    Lee, Sang-Gon
    Cho, Byung-Ryul
    Lee, Seung-Wook
    Lee, Nae-Hee
    Lee, Keun
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2012, 80 (05) : 799 - 806
  • [2] Efficacy and Safety of Rapamycin as Compared to Paclitaxel-Eluting Stents: A Meta-Analysis
    Juwana, Yahya B.
    Rasoul, Saman
    Ottervanger, Jan Paul
    Suryapranata, Harry
    JOURNAL OF INVASIVE CARDIOLOGY, 2010, 22 (07): : 312 - 316
  • [3] Comparison of Rapamycin- and Paclitaxel-Eluting Stents in Patients Undergoing Primary Percutaneous Coronary Intervention for ST-Elevation Myocardial Infarction
    Juwana, Yahya B.
    Suryapranata, Harry
    Ottervanger, Jan Paul
    De Luca, Giuseppe
    van't Hof, Arnoud W. J.
    Dambrink, Jan-Henk E.
    de Boer, Menko-Jan
    Gosselink, A. T. Marcel
    Hoorntje, Jan C. A.
    AMERICAN JOURNAL OF CARDIOLOGY, 2009, 104 (02): : 205 - 209
  • [4] Five-Year Clinical and Angiographic Outcomes of a Randomized Comparison of Sirolimus-Eluting and Paclitaxel-Eluting Stents Results of the Sirolimus-Eluting Versus Paclitaxel-Eluting Stents for Coronary Revascularization LATE Trial
    Raeber, Lorenz
    Wohlwend, Lea
    Wigger, Mathias
    Togni, Mario
    Wandel, Simon
    Wenaweser, Peter
    Cook, Stephane
    Moschovitis, Aris
    Vogel, Rolf
    Kalesan, Bindu
    Seiler, Christian
    Eberli, Franz
    Luescher, Thomas F.
    Meier, Bernhard
    Jueni, Peter
    Windecker, Stephan
    CIRCULATION, 2011, 123 (24) : 2819 - +
  • [5] In Vitro Evaluation of Paclitaxel-Eluting fully Bioabsorbable Stents with PLLA Coating
    Yamada, Hirokazu
    Yagi, Shinichi
    Kinoshita, Mitsuhiko
    Matsubara, Chisa
    Igaki, Keiji
    Yoshida, Yuji
    Yamane, Hideki
    SEN-I GAKKAISHI, 2015, 71 (10) : 302 - 309
  • [6] FASTTRACK -: Randomized trial of paclitaxel- and sirolimus-eluting stents in small coronary vessels
    Mehilli, J
    Dibra, A
    Kastrati, A
    Pache, J
    Dirschinger, J
    Schömig, A
    EUROPEAN HEART JOURNAL, 2006, 27 (03) : 260 - 266
  • [7] A Multicenter Randomized Trial Comparing Amphilimus-With Paclitaxel-Eluting Stents in De Novo Native Coronary Artery Lesions
    Carrie, Didier
    Berland, Jacques
    Verheye, Stefan
    Hauptmann, Karl Eugen
    Vrolix, Mathias
    Violini, Roberto
    Dibie, Alain
    Berti, Sergio
    Maupas, Eric
    Antoniucci, David
    Schofer, Joachim
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (15) : 1371 - 1376
  • [8] Randomized trial of three rapamycin-eluting stents with different coating strategies for the reduction of coronary restenosis
    Mehilli, Julinda
    Byrne, Robert A.
    Wieczorek, Anna
    Iijima, Raisuke
    Schulz, Stefanie
    Bruskina, Olga
    Pache, Juergen
    Wessely, Rainer
    Schoemig, Albert
    Kastrati, Adnan
    EUROPEAN HEART JOURNAL, 2008, 29 (16) : 1975 - 1982
  • [9] Comparison of Zotarolimus-Eluting Stents With Sirolimus- and Paclitaxel-Eluting Stents for Coronary Revascularization The ZEST (Comparison of the Efficacy and Safety of Zotarolimus-Eluting Stent with Sirolimus-Eluting and PacliTaxel-Eluting Stent for Coronary Lesions) Randomized Trial
    Park, Duk-Woo
    Kim, Young-Hak
    Yun, Sung-Cheol
    Kang, Soo-Jin
    Lee, Seung-Whan
    Lee, Cheol-Whan
    Park, Seong-Wook
    Seong, In-Whan
    Lee, Jae-Hwan
    Tahk, Seung-Jea
    Jeong, Myung-Ho
    Jang, Yangsoo
    Cheong, Sang-Sig
    Yang, Joo-Young
    Lim, Do-Sun
    Seung, Ki-Bae
    Chae, Jei-Keon
    Hur, Seung-Ho
    Lee, Sang-Gon
    Yoon, Junghan
    Lee, Nae-Hee
    Choi, Young-Jin
    Kim, Hyun-Sook
    Kim, Kee-Sik
    Kim, Hyo-Soo
    Hong, Taeg-Jong
    Park, Hun-Sik
    Park, Seung-Jung
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 56 (15) : 1187 - 1195
  • [10] Randomized Evaluation of Two Drug-Eluting Stents With Identical Metallic Platform and Biodegradable Polymer But Different Agents (Paclitaxel or Sirolimus) Compared Against Bare Stents: 1-Year Results of the PAINT Trial
    Lemos, Pedro A.
    Moulin, Bruno
    Perin, Marco A.
    Oliveira, Ludmilla A. R. R.
    Arruda, J. Airton
    Lima, Valter C.
    Lima, Antonio A. G.
    Caramori, Paulo R. A.
    Medeiros, Cesar R.
    Barbosa, Mauricio R.
    Brito, Fabio S., Jr.
    Ribeiro, Expedito E.
    Martinez, Eulogio E.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2009, 74 (05) : 665 - 673