Sutureless intrascleral posterior chamber intraocular lens fixation

被引:367
作者
Gabor, Scharioth G. B. [1 ]
Pavlidis, Mitrofanis M. [1 ]
机构
[1] Augenzentrum Recklinghausen, D-45657 Recklinghausen, Germany
关键词
D O I
10.1016/j.jcrs.2007.07.013
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
We report a technique for sutureless fixation of standard 3-piece posterior chamber intraocular lenses (PC IOLs) in the ciliary sulcus in eyes without capsule support, which we have used in cases of subluxated and luxated cataract and for secondary IOL implantation. Fixation of the haptics in a limbus-parallel scleral tunnel allows exact centration and provides axial stability of the PC IOL to prevent distortion. The technique uses uncomplicated maneuvers for standard 3-piece PC IOL fixation without the need for special haptic architecture or preparation.
引用
收藏
页码:1851 / 1854
页数:4
相关论文
共 36 条
[1]   Surgical repositioning of dislocated capsular tension rings [J].
Ahmed, IIK ;
Chen, SH ;
Kranemann, C ;
Wong, DT .
OPHTHALMOLOGY, 2005, 112 (10) :1725-1733
[2]   Spontaneous intraocular lens extrusion in a patient with scleromalacia secondary to herpes zoster ophthalmicus [J].
Ahmed, Taha Y. ;
Carrim, Zia I. ;
Diaper, Charles J. M. ;
Wykes, William N. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (05) :925-926
[3]   SIMPLIFIED TECHNIQUE FOR SUTURING DISLOCATED POSTERIOR CHAMBER INTRAOCULAR-LENS TO THE CILIARY SULCUS [J].
ANAND, R ;
BOWMAN, RW .
ARCHIVES OF OPHTHALMOLOGY, 1990, 108 (09) :1205-1206
[4]   Double-knot transscleral suture fixation technique for displaced intraocular lenses [J].
Azar, DT ;
Wiley, WF .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1999, 128 (05) :644-646
[5]  
BLOOM SM, 1990, OPHTHALMIC SURG LAS, V21, P851
[6]  
CHAN CK, 1992, OPHTHALMOLOGY, V99, P51
[7]   PERFLUOROCARBON LIQUIDS IN VITREORETINAL SURGERY [J].
CHANG, S .
INTERNATIONAL OPHTHALMOLOGY CLINICS, 1992, 32 (02) :153-163
[8]   SURGICAL TECHNIQUES FOR REPOSITIONING A DISLOCATED INTRAOCULAR-LENS, REPAIR OF IRIDODIALYSIS, AND SECONDARY INTRAOCULAR-LENS IMPLANTATION USING INNOVATIVE 25-GAUGE FORCEPS [J].
CHANG, S ;
COLL, GE .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1995, 119 (02) :165-174
[9]   Management of profound zonular dialysis or weakness with a new endocapsular ring designed for scleral fixation [J].
Cionni, RJ ;
Osher, RH .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1998, 24 (10) :1299-1306
[10]  
FANOUS MM, 1992, OPHTHALMIC SURG LAS, V23, P551