Polypropylene (pp) was functionalized in the melt phase by grafting with itaconic acid derivatives. 2,5-dimethyl-2,5-bis(tert-buthyl-peroxy) hexane (lupersol 101) was used as radical initiator. A Brabender Plasticorder was used for all the experiments. The optimum conditions for the grafting reaction were 190 degreesC, 75 rpm and 6 min. The itaconic acid derivatives used in this work were mono- and dimethyl esters. When dimethyl itaconate (DMI) was used as functional polar monomer, a maximum of 1.5% of grafting was reached. A similar value was found for grafting of monomethyl itaconate (MMI) where a maximum of 1.6% by weight of this monomer was incorporated in pp. The existence of grafted MMI and/or DMI in pp was confirmed by FT-IR spectroscopy. Carbonyl absorption bands from either MMI and/or DMI were observed in the FT-IR spectrum of the modified pp. The percentage of grafting attained was also followed by FT-IR analysis, where the amount of monomer incorporated in pp was estimated from a calibration curve established for the monomers used in this work. A systematic study of the reaction variables allowed the optimization of the grafting process. It was found that the percentage of grafting attained depends on the initial concentration of both monomer and initiator used in the reaction. Some properties of the modified pps were evaluated by employing dilute solution viscosity and differential scanning calorimetric (DSC) measurements. It was found that the molecular weight of the grafted polymer decreased with increasing percentage of grafting. DSC measurements indicated that functionalized pp samples have slightly higher crystallinity but show the same melting temperature as pp. (C) 2001 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:4751 / 4758
页数:8
相关论文
共 66 条
[1]  
Anttila U, 1999, J APPL POLYM SCI, V72, P877, DOI 10.1002/(SICI)1097-4628(19990516)72:7<877::AID-APP3>3.0.CO
[2]  
2-6
[3]   Graft-copolymerization of styrene on polypropylene in the solid phase [J].
Beenen, W ;
VanderWal, D ;
Janssen, LPBM ;
Buijtenhuijs, A ;
Hogt, AH .
MACROMOLECULAR SYMPOSIA, 1996, 102 :255-263
[4]   Fusion bonding of maleic anhydride grafted polypropylene-polyamide 6 blends to polyamide 6 [J].
Bidaux, JE ;
Smith, GD ;
Manson, JAE ;
Plummer, CJG ;
Hilborn, J .
POLYMER, 1998, 39 (24) :5939-5948
[5]   Fusion bonding of maleic anhydride grafted polypropylene to polyamide 6 via in situ block copolymer formation at the interface [J].
Bidaux, JE ;
Smith, GD ;
Bernet, N ;
Manson, JAE ;
Hilborn, J .
POLYMER, 1996, 37 (07) :1129-1136
[6]   Functionalization of polyolefins in the melt through reaction with molecules and macromolecules [J].
Ciardelli, F ;
Aglietto, M ;
Ruggeri, G ;
Passaglia, E ;
Castelvetro, V .
MACROMOLECULAR SYMPOSIA, 1997, 118 :311-316
[7]   SOME ASPECTS OF THERMAL-STABILITY OF POLY(ALKYL ITACONIC ACID-ESTERS) [J].
COWIE, JMG ;
HAQ, Z .
BRITISH POLYMER JOURNAL, 1977, 9 (03) :246-250
[8]   PHYSICAL-PROPERTIES OF POLYMERS BASED ON ITACONIC ACID [J].
COWIE, JMG .
PURE AND APPLIED CHEMISTRY, 1979, 51 (12) :2331-2343
[9]  
Demarquette NR, 1998, J APPL POLYM SCI, V70, P75, DOI 10.1002/(SICI)1097-4628(19981003)70:1<75::AID-APP9>3.0.CO
[10]  
2-R