Phantom-based evaluation method for surgical assistance devices in minimally invasive cochlear implantation

被引:1
作者
Lexow, G. Jakob [1 ]
Kluge, Marcel [1 ]
Majdani, Omid [1 ]
Lenarz, Thomas [1 ]
Rau, Thomas S. [1 ]
机构
[1] Hannover Med Sch, Dept Otolaryngol & Cluster Excellence Hearing4all, Carl Neuberg Str 1, D-30625 Hannover, Germany
来源
MEDICAL IMAGING 2017: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING | 2017年 / 10135卷
关键词
cochlear implant; minimally invasive surgery; phantom study; IN-VITRO; NAVIGATION; ACCURACY; SURGERY;
D O I
10.1117/12.2254381
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Several research groups have proposed individual solutions for surgical assistance devices to perform minimally invasive cochlear implantation. The main challenge is the drilling of a small bore hole from the surface of the skull to the inner ear at submillimetric accuracy. Each group tested the accuracy of their device in their respective test bench or in a small number of temporal bone specimens. This complicates the comparison of the different approaches. Thus, a simple and inexpensive phantom based evaluation method is proposed which resembles clinical conditions. The method is based on half-skull phantoms made of bone-substitute material - optionally equipped with an artificial skin replica to include skin incision within the evaluation procedure. Anatomical structures of the temporal bone derived from segmentations using clinical imaging data are registered into a computer tomographic scan of the skull phantom and used for the planning of the drill trajectory. Drilling is performed with the respective device under conditions close to the intraoperative setting. Evaluation of accuracy can either be performed through postoperative imaging or by means of added targets on the inside of the skull model. Two different targets are proposed: simple reference marks only for measuring the accuracy of the device and a target containing a scala tympani model for evaluation of the complete workflow including the insertion of the electrode carrier. Experiments using the presented method take place under reproducible conditions thus allowing the comparison of the different approaches. In addition, artificial phantoms are easier to obtain and handle than human specimens.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Minimal-invasive Cochlear Implantation: Surgical feasibility and first clinical experience
    Di Martino, Ercole F. N.
    von Hesberg, Jakob W. G.
    Chatzakos, Alkiviades
    Megerle, Michael
    Hinder, Raffael
    LARYNGO-RHINO-OTOLOGIE, 2018, 97 (11) : 777 - 783
  • [42] Evaluation of Clinical Performance of Ponto Implantation Using a Minimally Invasive Surgical Technique-A Prospective Multicenter Study
    Teunissen, Emma M.
    Aukema, Tjerk W.
    Banga, Rupan
    Eeg-Olofsson, Mans
    Hol, Myrthe K. S.
    Hougaard, Dan D.
    Tysome, James R.
    Johansson, Martin L.
    Svensson, Sara
    Powell, Harry R. F.
    OTOLOGY & NEUROTOLOGY, 2024, 45 (09) : 1037 - 1044
  • [43] Evaluation of Different Minimally Invasive Techniques in Surgical Treatment for Ventricular Septal Defect
    Liu Huagang
    Wang Zhiwei
    Xia Jun
    Hu Rui
    Wu Zhiyong
    Hu Xiaoping
    Ren Wei
    HEART LUNG AND CIRCULATION, 2018, 27 (03) : 365 - 370
  • [44] Minimally Invasive Cochlear Implantation Assisted by Bi-planar Device: An Exploratory Feasibility Study
    Ke Jia
    Zhang ShaoXing
    Hu Lei
    Li ChangSheng
    Zhu YunFeng
    Sun ShiLong
    Wang LiFeng
    Ma FuRong
    Department of OtorhinolarygologyHead and Neck Surgery Peking University Third Hospital Beijing China
    Robotics Institute School of Mechanical Engineering and Automation Beihang University Beijing China
    中华医学杂志英文版, 2016, 129 (20) : 2476 - 2483
  • [45] Does robotic assistance improve efficiency in performing complex minimally invasive surgical procedures?
    Jayaraman, Shiva
    Quan, Douglas
    Al-Ghamdi, Ibrahim
    El-Deen, Firas
    Schlachta, Christopher M.
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2010, 24 (03): : 584 - 588
  • [46] HiRes 90K implantation using a minimally invasive surgical technique
    Perry, BP
    Hernandez, K
    Syms, CA
    King, SM
    Olsson, JE
    COCHLEAR IMPLANTS, 2004, 1273 : 125 - 128
  • [47] Research on autonomous operation method for minimally invasive surgical robot
    Yue, Longwang
    INTERNATIONAL JOURNAL OF AUTOMATION AND CONTROL, 2024, 18 (05) : 574 - 587
  • [48] Minimally Invasive Spinal Surgical Robot Velocity Control Method
    Song, Guoli
    Zhao, Yiwen
    Han, Jianda
    Wang, Zheng
    Du, Huibin
    PROCEEDINGS OF 2016 2ND INTERNATIONAL CONFERENCE ON CONTROL SCIENCE AND SYSTEMS ENGINEERING (ICCSSE), 2016, : 227 - 231
  • [49] Miniature temperature insensitive fiber optic sensors for minimally invasive surgical devices
    Rajan, Ginu
    Callaghan, Dean
    Semenova, Yuliya
    Farrell, Gerald
    21ST INTERNATIONAL CONFERENCE ON OPTICAL FIBER SENSORS, 2011, 7753
  • [50] Accuracy of linear drilling in temporal bone using drill press system for minimally invasive cochlear implantation
    Neal P. Dillon
    Ramya Balachandran
    Robert F. Labadie
    International Journal of Computer Assisted Radiology and Surgery, 2016, 11 : 483 - 493