Efficacy of a computed tomography-based navigation system for placement of the acetabular component in total hip arthroplasty for developmental dysplasia of the hip

被引:28
作者
Tsutsui, Takahiko [1 ]
Goto, Tomohiro [1 ]
Wada, Keizo [1 ]
Takasago, Tomoya [1 ]
Hamada, Daisuke [1 ]
Sairyo, Koichi [1 ]
机构
[1] Tokushima Univ, Inst Biomed Sci, Dept Orthoped, Grad Sch, 3-18-15 Kuramoto, Tokushima 7708503, Japan
关键词
acetabulum; arthroplasty; hip dislocation; hip joint; osteoarthritis; REPLACEMENT; DISLOCATION; ORIENTATION; ACCURACY; CHARNLEY;
D O I
10.1177/2309499017727954
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: Developmental dysplasia of the hip (DDH) presents a considerable surgical challenge in total hip arthroplasty (THA). Although the usefulness of computed tomography (CT)-based navigation in cup alignment has been reported, few reports have evaluated three-dimensional (3-D) cup positioning against the acetabulum specifically in patients with DDH. The purpose of this study was to evaluate the efficacy of a CT-based navigation system for alignment and spatial positioning of the cup in THA for patients with DDH. Methods: We reviewed 174 DDH THA cases in which CT-based navigation was used, and 75 cases in which a mechanical guide was used as a control group. Postoperative cup alignment and spatial positioning were evaluated by superimposition of a 3-D cup template onto the actual implanted cup using postoperative CT images, with pelvic coordinates matching the preoperative planning. Results: The proportion within the combined target zone (inclination and anteversion) was 97.7% in the navigation group and 61.3% in the non-navigation group. The mean absolute error between the intraoperative record and the postoperative measurement was 1.5 degrees 1.3 degrees for inclination and 2.1 degrees +/- 1.8 degrees for anteversion in the navigation group. For acetabular cup positioning, the mean discrepancy between the preoperative planning and the postoperative measurements was 1.9 +/- 1.6 mm on the transverse axis, 2.8 +/- 2.3 mm on the longitudinal axis, and 1.7 +/- 1.3 mm on the sagittal axis. Conclusion: THA using a CT-based navigation system achieved quite high accuracy of cup alignment angles and spatial cup positioning in primary THA for patients with DDH.
引用
收藏
页数:7
相关论文
共 50 条
[41]   Combined anteversion technique in total hip arthroplasty for Crowe IV developmental dysplasia of the hip [J].
Zhu, Biao ;
Su, Changzheng ;
He, Yeteng ;
Chai, Xingyu ;
Li, Zhen ;
Hou, Zhenyang ;
Lou, Tengteng ;
Yan, Xinfeng .
HIP INTERNATIONAL, 2017, 27 (06) :589-594
[42]   Acetabular component position significantly influences the rebalancing of pelvic sagittal inclination following total hip arthroplasty in patients with Crowe type III/IV developmental dysplasia of the hip [J].
Zhai, Z. ;
Zhang, J. ;
Li, H. ;
Mao, Y. ;
Zhu, Z. ;
Zhao, J. ;
Yu, D. ;
Zhao, C. .
BONE & JOINT JOURNAL, 2025, 107B (02) :149-156
[43]   Does Degree of the Pelvic Deformity Affect the Accuracy of Computed Tomography-Based Hip Navigation? [J].
Kajino, Yoshitomo ;
Kabata, Tamon ;
Maeda, Toru ;
Iwai, Shintaro ;
Kuroda, Kazunari ;
Tsuchiya, Hiroyuki .
JOURNAL OF ARTHROPLASTY, 2012, 27 (09) :1651-1657
[44]   Improving Acetabular Component Positioning in Total Hip Arthroplasty: A Cadaveric Study of an Inertial Navigation Tool and a Novel Registration Method [J].
Shatrov, Jobe ;
Marsden-Jones, Daniel ;
Lyons, Matt ;
Walter, William L. .
HSS JOURNAL, 2022, 18 (03) :358-367
[45]   Hospital Costs of Total Hip Arthroplasty for Developmental Dysplasia of the Hip [J].
Ashraf, Ali ;
Larson, A. Noelle ;
Maradit-Kremers, Hilal ;
Kremers, Walter K. ;
Lewallen, David G. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2014, 472 (07) :2237-2244
[46]   Augmented Reality for Acetabular Component Placement in Direct Anterior Total Hip Arthroplasty [J].
Alexander, Clayton ;
Loeb, Alexander E. ;
Fotouhi, Javad ;
Navab, Nassir ;
Armand, Mehran ;
Khanuja, Harpal S. .
JOURNAL OF ARTHROPLASTY, 2020, 35 (06) :1636-+
[47]   Challenges in Total Hip Arthroplasty in the Setting of Developmental Dysplasia of the Hip [J].
Greber, Eric M. ;
Pelt, Christopher E. ;
Gililland, Jeremy M. ;
Anderson, Mike B. ;
Erickson, Jill A. ;
Peters, Christopher L. .
JOURNAL OF ARTHROPLASTY, 2017, 32 (09) :S38-S44
[48]   The outcome of total hip arthroplasty in patients with developmental dysplasia of the hip [J].
Akbaba, Yildiz Analay ;
Can, Ata ;
Erdogan, Fahri .
JOURNAL OF BACK AND MUSCULOSKELETAL REHABILITATION, 2019, 32 (06) :913-919
[49]   Surgical Approach and Hip Laterality Affect Accuracy of Acetabular Component Placement in Primary Total Hip Arthroplasty [J].
Crawford, David A. ;
Adams, Joanne B. ;
Hobbs, Gerald R. ;
Lombardi, Adolph V., Jr. ;
Berend, Keith R. .
SURGICAL TECHNOLOGY INTERNATIONAL-INTERNATIONAL DEVELOPMENTS IN SURGERY AND SURGICAL RESEARCH, 2019, 35
[50]   Acetabular Dysplasia and Surgical Approaches Other Than Direct Anterior Increases Risk for Malpositioning of the Acetabular Component in Total Hip Arthroplasty [J].
Gromov, Kirill ;
Greene, Meridith E. ;
Huddleston, James I. ;
Emerson, Roger ;
Gebuhr, Peter ;
Malchau, Henrik ;
Troelsen, Anders .
JOURNAL OF ARTHROPLASTY, 2016, 31 (04) :835-841