Efficacy of a computed tomography-based navigation system for placement of the acetabular component in total hip arthroplasty for developmental dysplasia of the hip

被引:28
作者
Tsutsui, Takahiko [1 ]
Goto, Tomohiro [1 ]
Wada, Keizo [1 ]
Takasago, Tomoya [1 ]
Hamada, Daisuke [1 ]
Sairyo, Koichi [1 ]
机构
[1] Tokushima Univ, Inst Biomed Sci, Dept Orthoped, Grad Sch, 3-18-15 Kuramoto, Tokushima 7708503, Japan
关键词
acetabulum; arthroplasty; hip dislocation; hip joint; osteoarthritis; REPLACEMENT; DISLOCATION; ORIENTATION; ACCURACY; CHARNLEY;
D O I
10.1177/2309499017727954
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: Developmental dysplasia of the hip (DDH) presents a considerable surgical challenge in total hip arthroplasty (THA). Although the usefulness of computed tomography (CT)-based navigation in cup alignment has been reported, few reports have evaluated three-dimensional (3-D) cup positioning against the acetabulum specifically in patients with DDH. The purpose of this study was to evaluate the efficacy of a CT-based navigation system for alignment and spatial positioning of the cup in THA for patients with DDH. Methods: We reviewed 174 DDH THA cases in which CT-based navigation was used, and 75 cases in which a mechanical guide was used as a control group. Postoperative cup alignment and spatial positioning were evaluated by superimposition of a 3-D cup template onto the actual implanted cup using postoperative CT images, with pelvic coordinates matching the preoperative planning. Results: The proportion within the combined target zone (inclination and anteversion) was 97.7% in the navigation group and 61.3% in the non-navigation group. The mean absolute error between the intraoperative record and the postoperative measurement was 1.5 degrees 1.3 degrees for inclination and 2.1 degrees +/- 1.8 degrees for anteversion in the navigation group. For acetabular cup positioning, the mean discrepancy between the preoperative planning and the postoperative measurements was 1.9 +/- 1.6 mm on the transverse axis, 2.8 +/- 2.3 mm on the longitudinal axis, and 1.7 +/- 1.3 mm on the sagittal axis. Conclusion: THA using a CT-based navigation system achieved quite high accuracy of cup alignment angles and spatial cup positioning in primary THA for patients with DDH.
引用
收藏
页数:7
相关论文
共 50 条
[21]   The accuracy of acetabular cup placement in primary total hip arthroplasty using an image-free navigation system [J].
Naito, Yohei ;
Hasegawa, Masahiro ;
Tone, Shine ;
Wakabayashi, Hiroki ;
Sudo, Akihiro .
BMC MUSCULOSKELETAL DISORDERS, 2021, 22 (01)
[22]   Current concepts in developmental dysplasia of the hip and Total hip arthroplasty [J].
Wang, Yan .
ARTHROPLASTY, 2019, 1 (01)
[23]   Accuracy of cup placement and pelvic motion in total hip arthroplasty in the lateral decubitus position using a new computed tomography-based navigation system with augmented reality technology [J].
Naito, Yohei ;
Hasegawa, Masahiro ;
Tone, Shine ;
Wakabayashi, Hiroki ;
Sudo, Akihiro .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2024, 144 (05) :2381-2389
[24]   Computed tomographic measurement of acetabular and femoral component version in total hip arthroplasty [J].
Fujishiro, Takaaki ;
Hayashi, Shinya ;
Kanzaki, Noriyuki ;
Hashimoto, Shingo ;
Kurosaka, Masahiro ;
Kanno, Taiki ;
Masuda, Takeshi .
INTERNATIONAL ORTHOPAEDICS, 2014, 38 (05) :941-946
[25]   Computer navigation of the acetabular component in total hip arthroplasty: a narrative review [J].
Davenport, Dominic ;
Kavarthapu, Venu .
EFORT OPEN REVIEWS, 2016, 1 (07) :279-285
[26]   Robotic-assisted total hip arthroplasty in patients with developmental dysplasia of the hip [J].
Zhang, Shuai ;
Ma, Mingyang ;
Kong, Xiangpeng ;
Zhou, Yonggang ;
Chen, Jiying ;
Chai, Wei .
INTERNATIONAL ORTHOPAEDICS, 2024, 48 (05) :1189-1199
[27]   Patient-specific instrumentation improves the accuracy of acetabular component placement in total hip arthroplasty [J].
Spencer-Gardner, L. ;
Pierrepont, J. ;
Topham, M. ;
Bare, J. ;
McMahon, S. ;
Shimmin, A. J. .
BONE & JOINT JOURNAL, 2016, 98B (10) :1342-1346
[28]   Clinical accuracy and precision of hip resurfacing arthroplasty using computed tomography-based navigation [J].
Ryuichi Sato ;
Masaki Takao ;
Hidetoshi Hamada ;
Takashi Sakai ;
Keishi Marumo ;
Nobuhiko Sugano .
International Orthopaedics, 2019, 43 :1807-1814
[29]   Acetabular Component Positioning in Total Hip Arthroplasty: An Evidence-Based Analysis [J].
Moskal, Joseph T. ;
Capps, Susan G. .
JOURNAL OF ARTHROPLASTY, 2011, 26 (08) :1432-1437
[30]   Anteversion of the Acetabular Component Aligned With the Transverse Acetabular Ligament in Total Hip Arthroplasty [J].
Miyoshi, Hideaki ;
Mikami, Hiroshi ;
Oba, Koichi ;
Amari, Rui .
JOURNAL OF ARTHROPLASTY, 2012, 27 (06) :916-922