Intrafraction motion of the prostate during external-beam radiation therapy: Analysis of 427 patients with implanted fiducial markers

被引:157
作者
Kotte, Alexis N. T. J. [1 ]
Hofman, Pieter [1 ]
Lagendijk, Jan J. W. [1 ]
van Vulpen, Marco [1 ]
van der Heide, Uulke A. [1 ]
机构
[1] Univ Med Ctr, Dept Radiotherapy, NL-3584 CX Utrecht, Netherlands
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2007年 / 69卷 / 02期
关键词
fiducial markers; prostate; position verification; intrafraction motion;
D O I
10.1016/j.ijrobp.2007.03.029
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To analyze the intrafraction motion of the prostate during external-beam radiation therapy of patients with prostate cancer. Methods and Materials: Between August 2001-December 2005, 427 patients with Stage T3Nx/0Mx/0 prostate carcinoma received intensity-modulated radiation therapy treatment combined with position verification with fiducial gold markers. For a total of 11,426 treatment fractions (average, 27 per patient), portal images were taken of the first segment of all five beams. The irradiation time of the technique varied between 5-7 min. From these data, the location of gold markers could be established within every treatment beam under the assumption of minimal marker movement. Results: In 66% of treatment fractions, a motion outside a range of 2 mm was observed, with 28% outside a range of 3 mm. The intrafraction marker movements showed that motion directions were often reversed. However, the effect was small. Even with perfect online position-correction at the start of irradiation, intrafraction motion caused position uncertainty, but systematic errors (Sigma) were limited to < 0.6 mm, and random errors (sigma) to < 0.9 mm. This would result in a lower limit of 2 mm for margins, in the absence of any other uncertainties. Conclusions: Intrafraction motion of the prostate occurs frequently during external-beam irradiation on a time scale of 5-7 min. Margins of 2 mm account for these intrafraction motions. However, larger margins are required in practice to accommodate other uncertainties in the treatment. (c) 2007 Elsevier Inc.
引用
收藏
页码:419 / 425
页数:7
相关论文
共 23 条
[1]   Automated localization of the prostate at the time of treatment using implanted radiopaque markers: Technical feasibility [J].
Balter, JM ;
Lam, KL ;
Sandler, HM ;
Littles, JF ;
Bree, RL ;
TenHaken, RK .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 33 (05) :1281-1286
[2]   Performing daily prostate targeting with a standard V-EPID and an automated radio-opaque marker detection algorithm [J].
Beaulieu, L ;
Girouard, LM ;
Aubin, S ;
Aubry, JF ;
Brouard, L ;
Roy-Lacroix, L ;
Dumont, J ;
Tremblay, D ;
Laverdière, J ;
Vigneault, E .
RADIOTHERAPY AND ONCOLOGY, 2004, 73 (01) :61-64
[3]   A VERIFICATION PROCEDURE TO IMPROVE PATIENT SET-UP ACCURACY USING PORTAL IMAGES [J].
BEL, A ;
VANHERK, M ;
BARTELINK, H ;
LEBESQUE, JV .
RADIOTHERAPY AND ONCOLOGY, 1993, 29 (02) :253-260
[4]   Clinical feasibility study for the use of implanted gold seeds in the prostate as reliable positioning markers during megavoltage irradiation [J].
Dehnad, H ;
Nederveen, AJ ;
van der Heide, UA ;
van Moorselaar, RJA ;
Hofman, P ;
Lagendijk, JJW .
RADIOTHERAPY AND ONCOLOGY, 2003, 67 (03) :295-302
[5]   Prostate gland motion assessed with cine-magnetic resonance imaging (cine-MRI) [J].
Ghilezan, MJ ;
Jaffray, DA ;
Siewerdsen, JH ;
van Herk, M ;
Shetty, A ;
Sharpe, MB ;
Jafri, SZ ;
Vicini, FA ;
Matter, RC ;
Brabbins, DS ;
Martinez, AA .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 62 (02) :406-417
[6]   A comparison of daily CT localization to a daily ultrasound-based system in prostate cancer [J].
Lattanzi, J ;
McNeeley, S ;
Pinover, W ;
Horwitz, E ;
Das, I ;
Schultheiss, TE ;
Hanks, GE .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 43 (04) :719-725
[7]   Assessment of residual error for online cone-beam CT-guided treatment of prostate cancer patients [J].
Létourneau, D ;
Martinez, AA ;
Lockman, D ;
Yan, D ;
Vargas, C ;
Ivaldi, G ;
Wong, J .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 62 (04) :1239-1246
[8]   Daily prostate targeting using implanted radiopaque markers [J].
Litzenberg, D ;
Dawson, LA ;
Sandler, H ;
Sanda, MG ;
McShan, D ;
Ten Haken, RK ;
Lam, KL ;
Brock, KK ;
Balter, JM .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 52 (03) :699-703
[9]   Influence of intrafraction motion on margins for prostate radiotherapy [J].
Litzenberg, DW ;
Balter, JM ;
Hadley, SW ;
Sandler, HM ;
Willoughby, TR ;
Kupelian, PA ;
Levine, L .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 65 (02) :548-553
[10]   Detection of fiducial gold markers for automatic on-line megavoltage position verification using a marker extraction kernel (MEK) [J].
Nederveen, A ;
Lagendijk, J ;
Hofman, P .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 47 (05) :1435-1442