Impedance balancing analysis for power-line interference elimination in ECG signal

被引:0
|
作者
Adli [1 ]
Yamamoto, Y [1 ]
机构
[1] Okayama Univ, Dept Elect & Elect Engn, Okayama 7008530, Japan
关键词
D O I
暂无
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
This paper describes an analysis of skin-electrode impedance balance for power-line interference elimination from ECG signal. This work is based on previous authors and conducted in three steps: The first step consists analysis of impedance balancing system. The second one is to examine the measurement system of power-line interference elimination using a physical model. And finally, we use the previous condition for checking of power-line interference elimination validity in real ECG signal recording. Result has shown that skill-electrode impedance balance can be achieved by using an impedance controller so that interference can be eliminated to very low value. In other word, to reduce skin-electrode unbalance that skin abrasion is unnecessary. Thus, this work is improvement method of previous authors and it is very important for safety in measurement system of biopotential signals.
引用
收藏
页码:235 / 238
页数:4
相关论文
共 50 条
  • [31] Quantitative analysis of errors due to power-line interference and base-line drift in detection of onsets and offsets in ECG using wavelets
    J. S. Sahambi
    S. N. Tandon
    R. K. P. Bhatt
    Medical and Biological Engineering and Computing, 1997, 35 : 747 - 751
  • [32] Quantitative analysis of errors due to power-line interference and base-line drift in detection of onsets and offsets in ECG using wavelets
    Electrical Engineering Department, Indian Institute of Technology Delhi, Hauz Khas, New Delhi 110 016, India
    不详
    MED. BIOL. ENG. COMPUT., 6 (747-751):
  • [33] Adaptive motion-artifact reduction in capacitive ECG measurements by using the power-line interference
    Xu, Lin
    Rabotti, Chiara
    Zhang, Yijing
    Harpe, Pieter J. A.
    Mischi, Massimo
    Meftah, Mohammed
    Ouzounov, Sotir
    2018 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS (MEMEA), 2018, : 195 - 199
  • [34] Suppression of AC railway power-line interference in ECG signals recorded by public access defibrillators
    Dotsinsky, Ivan
    BIOMEDICAL ENGINEERING ONLINE, 2005, 4 (1)
  • [35] Quantitative analysis of errors due to power-line interference and base-line drift in detection of onsets and offsets in ECG using wavelets
    Sahambi, JS
    Tandon, SN
    Bhatt, RKP
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1997, 35 (06) : 747 - 751
  • [36] Elimination on power line interference from ECG signal using combined bidirectional narrow-band notch filter
    Zaitsev E.V.
    Biophysics, 2015, 60 (4) : 656 - 658
  • [37] Comb Filter for Elimination of Unwanted Power Line Interference in Biomedical Signal
    Ranjan, Rajeev Kr
    Choubey, Chandan Kr
    Nagar, Bal Chand
    Paul, Sajal Kr
    JOURNAL OF CIRCUITS SYSTEMS AND COMPUTERS, 2016, 25 (06)
  • [38] Power-line interference removal of bioelectric signal measurement by using genetic adaptive filter
    Lin, Bor-Shyh
    Lin, Bor-Shing
    Chong, Fok-Ching
    2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, : 4557 - 4559
  • [39] ELECTROMAGNETIC-INTERFERENCE FROM DIGITAL SIGNAL TRANSMISSION ON POWER-LINE CARRIER CHANNELS
    CRISTINA, S
    DAMORE, M
    FELIZIANI, M
    IEEE TRANSACTIONS ON POWER DELIVERY, 1989, 4 (02) : 898 - 905
  • [40] Baseline Wander and Power-Line Interference Removal from ECG Signals Using Fourier Decomposition Method
    Singh, Pushpendra
    Srivastava, Ishita
    Singhal, Amit
    Gupta, Anubha
    MACHINE INTELLIGENCE AND SIGNAL ANALYSIS, 2019, 748 : 25 - 36