Impedance balancing analysis for power-line interference elimination in ECG signal

被引:0
|
作者
Adli [1 ]
Yamamoto, Y [1 ]
机构
[1] Okayama Univ, Dept Elect & Elect Engn, Okayama 7008530, Japan
关键词
D O I
暂无
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
This paper describes an analysis of skin-electrode impedance balance for power-line interference elimination from ECG signal. This work is based on previous authors and conducted in three steps: The first step consists analysis of impedance balancing system. The second one is to examine the measurement system of power-line interference elimination using a physical model. And finally, we use the previous condition for checking of power-line interference elimination validity in real ECG signal recording. Result has shown that skill-electrode impedance balance can be achieved by using an impedance controller so that interference can be eliminated to very low value. In other word, to reduce skin-electrode unbalance that skin abrasion is unnecessary. Thus, this work is improvement method of previous authors and it is very important for safety in measurement system of biopotential signals.
引用
收藏
页码:235 / 238
页数:4
相关论文
共 50 条
  • [1] Power-line interference detection and suppression in ECG signal processing
    Lin, Yue-Der
    Hu, Yu Hen
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2008, 55 (01) : 354 - 357
  • [2] Power-line interference and baseline wander elimination in ECG using VMD and EWT
    Mir, Haroon Yousuf
    Singh, Omkar
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2024, 27 (15) : 2111 - 2130
  • [3] Baseline wander and power-line interference elimination of ECG signals using efficient signal-piloted filtering
    Mian Qaisar, Saeed
    HEALTHCARE TECHNOLOGY LETTERS, 2020, 7 (04) : 114 - 118
  • [4] Power-line interference elimination from ECG in case of non-multiplicity between the sampling rate and the power-line frequency
    Mihov, Georgy
    Dotsinsky, Ivan
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2008, 3 (04) : 334 - 340
  • [5] Elimination of power line interference in ECG signal using inverse loop
    Adli
    Yamamoto, Y
    Nakamura, T
    PROCEEDINGS OF THE 20TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 20, PTS 1-6: BIOMEDICAL ENGINEERING TOWARDS THE YEAR 2000 AND BEYOND, 1998, 20 : 3313 - 3314
  • [6] FILTERING OF ECG SIGNALS CORRUPTED WITH POWER-LINE INTERFERENCE
    SHWEDYK, E
    CELLER, BG
    PROCEEDINGS OF THE ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, PTS 1-4, 1988, : 151 - 151
  • [7] Power-line Interference in the ECG Obtained with Capacitive Electrodes
    Luna-Lozano, Pablo S.
    Pallas-Areny, Ramon
    5TH EUROPEAN CONFERENCE OF THE INTERNATIONAL FEDERATION FOR MEDICAL AND BIOLOGICAL ENGINEERING, PTS 1 AND 2, 2012, 37 : 910 - +
  • [8] Power Line Interference Elimination in ECG Signals
    Ladrova, Martina
    Martinek, Radek
    Jaros, Rene
    JOURNAL OF BIOMIMETICS BIOMATERIALS AND BIOMEDICAL ENGINEERING, 2019, 41 : 105 - 115
  • [9] A Novel Cyclic Convolution Based Regularization Method for Power-Line Interference Removal in ECG Signal
    Sujadevi, V. G.
    Soman, K. P.
    Kumar, S. Sachin
    Mohan, Neethu
    ADVANCES IN SIGNAL PROCESSING AND INTELLIGENT RECOGNITION SYSTEMS, 2018, 678 : 116 - 126
  • [10] An Approach to Successful Power-line Interference Suppression in ECG Signals
    Dotsinsky I.
    Dotsinsky, Ivan, 1600, Institute of Biophysics and Biomedical Engineering (26): : 83 - 92