Growth and Partial Discharge Characteristics of Electrical Tree in XLPE under AC-DC Composite Voltage

被引:47
作者
Liu, Hechen [1 ]
Liu, Yunpeng [1 ,2 ]
Li, Yanda [1 ]
Zhong, Ping [1 ]
Rui, Haoran [1 ]
机构
[1] North China Elect Power Univ, Hebei Prov Key Lab Power Transmiss Equipment Secu, Baoding City 071003, Hebei, Peoples R China
[2] North China Elect Power Univ, State Key Lab Alternate Elect Power Syst Renewabl, Beijing 102206, Peoples R China
关键词
Electrical tree; AC-DC composite voltage; AC component; XLPE; DC cable; partial discharge; REPETITIVE PULSE VOLTAGE; CABLE INSULATION; LOW-TEMPERATURE; PROPAGATION; INITIATION; MECHANISM; PMMA;
D O I
10.1109/TDEI.2017.006537
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The growth characteristics of electrical trees under DC and AC voltages are quite different. In order to investigate the influences of AC component in HVDC cable system on the electrical tree properties, the growth and discharge characteristics of electrical trees under AC-DC composite voltages were studied in this paper. The results showed that the AC component greatly accelerated the developing process of the electrical trees. The influences of the positive and negative DC bias voltages on the electrical tree growth properties were quite different. The growth rate under negative DC bias voltage was similar to that under pure AC voltage and pine-branch type electrical trees were more likely to form. In contrast, the growth rate of the electrical tree increased with the increase of the positive DC bias voltage and it was much faster than the negative DC biased one. More branch-like electrical trees would form under positive DC bias voltage. When the AC component decreased, the developing process of the electrical tree was fairly tough and it was easy to form bush-like electrical trees, which were the typical conducive electrical trees with fairly small discharges. Under the positive DC bias voltage, there was a fast re-growth process of electrical tree after the bush tree formed, and the positive DC bias voltage could promote the coming of the re-growth process. However, the detected partial discharge during this process was quite small. The test results indicated that it may pose a great threat to the safety of the cable insulation if there is a large AC component in the HVDC cable system.
引用
收藏
页码:2282 / 2290
页数:9
相关论文
共 50 条
  • [31] Influence of DC Component on Partial Discharge Characteristics of Needle-plane Defect in Oil-paper Insulation Under AC-DC Combined Voltage
    Li X.
    Ji S.
    Cui Y.
    Pan L.
    Zhu L.
    Xiao Y.
    Gaodianya Jishu/High Voltage Engineering, 2019, 45 (12): : 3869 - 3878
  • [32] Influence of DC pre-stress of initiation characteristics on electrical tree in XLPE under DC-impulse voltage
    Meng, Shaoxin
    Xu, Xiaobin
    Liu, Hechen
    Guo, Zhanpeng
    Xie, Zhuopeng
    Liu, Aijing
    2020 5TH ASIA CONFERENCE ON POWER AND ELECTRICAL ENGINEERING (ACPEE 2020), 2020, : 1914 - 1917
  • [33] Characteristics of Electrical Tree and Effects of Barriers on Electrical Tree Propagation under AC Voltage in LDPE
    Song, Wei
    Zhang, Dong
    Wang, Xuan
    Lei, Qingquan
    ICPADM 2009: PROCEEDINGS OF THE 9TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1-3, 2009, : 546 - 549
  • [34] Influencing Mechanism of Adhesive on Partial Discharge of Pressboard Block under AC/DC Composite Voltage
    Zhang, Yi
    Qi, Bo
    Ma, Yukun
    Huang, Meng
    Yuan, Qing
    Lv, Yuzhen
    Jiao, Yanqiu
    Li, Chengrong
    Zhang, Shuqi
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2021, 28 (06) : 1883 - 1891
  • [35] Experiments on corona discharge under AC and DC composite voltage
    Zhu, Zhengyi
    Li, Ruihai
    Wang, Guoli
    Chen, Can
    Jia, Zhidong
    Guan, Zhicheng
    Gaodianya Jishu/High Voltage Engineering, 2012, 38 (08): : 2001 - 2007
  • [36] Characteristics of partial discharge by AC and DC
    Kim, Jeongtae
    Kim, Dongwook
    Kijin Nam
    Choi, Won
    Lee, Bangwook
    Koo, Jayoon
    PROCEEDINGS OF 2012 IEEE INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS (IEEE CMD 2012), 2012, : 489 - 492
  • [37] Growth and partial discharge characteristics of DC electrical trees in cross-linked polyethylene
    Liu, Hechen
    Zhang, Mingjia
    Liu, Yunpeng
    Xu, Xiaobin
    Liu, Aijing
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2019, 26 (06) : 1965 - 1972
  • [38] Effect of DC Pre-stress Time on Initiation Characteristics of Electrical Tree in XLPE Under DC Superimposed Impulse Voltage
    Liu H.
    Xu X.
    Liu Y.
    Meng S.
    Guo Z.
    Zhang M.
    Gaodianya Jishu/High Voltage Engineering, 2021, 47 (02): : 671 - 678
  • [39] Effect of Space Charge on Electrical Tree Initiation in XLPE/Voltage Stabilizer Composites Under AC Voltage
    Han, Tao
    Li, Qiang
    Zhao, Xin
    Yao, Yufei
    Li, Jing
    Gao, Yu
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2023, 30 (05) : 2173 - 2180
  • [40] Propagation and Partial Discharge Characteristics of Electrical Trees in XLPE Cable Under High Temperatures and High Gas Pressures
    Zhou L.
    Qiu Q.
    Cheng R.
    Hu J.
    Cai J.
    Zhou, Lijun (ljzhou10@163.com), 2018, Science Press (44): : 1421 - 1427