Growth and Partial Discharge Characteristics of Electrical Tree in XLPE under AC-DC Composite Voltage

被引:47
作者
Liu, Hechen [1 ]
Liu, Yunpeng [1 ,2 ]
Li, Yanda [1 ]
Zhong, Ping [1 ]
Rui, Haoran [1 ]
机构
[1] North China Elect Power Univ, Hebei Prov Key Lab Power Transmiss Equipment Secu, Baoding City 071003, Hebei, Peoples R China
[2] North China Elect Power Univ, State Key Lab Alternate Elect Power Syst Renewabl, Beijing 102206, Peoples R China
关键词
Electrical tree; AC-DC composite voltage; AC component; XLPE; DC cable; partial discharge; REPETITIVE PULSE VOLTAGE; CABLE INSULATION; LOW-TEMPERATURE; PROPAGATION; INITIATION; MECHANISM; PMMA;
D O I
10.1109/TDEI.2017.006537
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The growth characteristics of electrical trees under DC and AC voltages are quite different. In order to investigate the influences of AC component in HVDC cable system on the electrical tree properties, the growth and discharge characteristics of electrical trees under AC-DC composite voltages were studied in this paper. The results showed that the AC component greatly accelerated the developing process of the electrical trees. The influences of the positive and negative DC bias voltages on the electrical tree growth properties were quite different. The growth rate under negative DC bias voltage was similar to that under pure AC voltage and pine-branch type electrical trees were more likely to form. In contrast, the growth rate of the electrical tree increased with the increase of the positive DC bias voltage and it was much faster than the negative DC biased one. More branch-like electrical trees would form under positive DC bias voltage. When the AC component decreased, the developing process of the electrical tree was fairly tough and it was easy to form bush-like electrical trees, which were the typical conducive electrical trees with fairly small discharges. Under the positive DC bias voltage, there was a fast re-growth process of electrical tree after the bush tree formed, and the positive DC bias voltage could promote the coming of the re-growth process. However, the detected partial discharge during this process was quite small. The test results indicated that it may pose a great threat to the safety of the cable insulation if there is a large AC component in the HVDC cable system.
引用
收藏
页码:2282 / 2290
页数:9
相关论文
共 50 条
  • [11] Partial Discharge Characteristics and Growth Stage Recognition of Electrical Tree in XLPE Insulation
    Yang, Zhuoran
    Gao, Yuan
    Deng, Jingfang
    Lv, Lixiang
    IEEE ACCESS, 2023, 11 : 145527 - 145535
  • [12] Electrical Tree Growth Structural Analysis of XLPE Cable Insulation under Different AC Voltage
    Sahoo, Rakesh
    Karmakar, Subrata
    PROCEEDINGS OF 2021 5TH INTERNATIONAL CONFERENCE ON CONDITION ASSESSMENT TECHNIQUES IN ELECTRICAL SYSTEMS (IEEE CATCON 2021), 2021, : 5 - 10
  • [13] Partial Discharge Characteristics in Oil-paper Insulation under Combined AC-DC Voltage
    Sha, Yanchao
    Zhou, Yuanxiang
    Li, Jinzhong
    Wang, Jianyi
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2014, 21 (04) : 1529 - 1539
  • [14] Characteristics of Partial Discharge in Oil-paper Insulated Needle Plate Electrode Model Under Composite AC-DC Voltage
    Liu, Hongshun
    Xue, Zhitong
    Li, Simeng
    Li, Qingquan
    He, Dongxin
    Xia, Tian
    Guo, Jian
    CSEE JOURNAL OF POWER AND ENERGY SYSTEMS, 2020, 6 (04): : 848 - 857
  • [15] Electrical Tree Growth Behavior Under AC and DC High Voltage in Power Cables
    Saleh, Mohammad AlShaikh
    Refaat, Shady S.
    Olesz, Marek
    Abu-Rub, Haitham
    2021 96TH IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (CEIDP 2021) / 16TH IEEE NANOTECHNOLOGY MATERIALS AND DEVICES CONFERENCE (IEEE NMDC 2021), 2021, : 269 - 274
  • [16] Partial Discharge Characteristics of Typical Defects in XLPE Cable Under DC Voltage
    Du H.
    Guan H.
    Chen X.
    Hou S.
    Yang M.
    Wang X.
    Gaodianya Jishu/High Voltage Engineering, 2021, 47 (02): : 555 - 563
  • [17] Effect of Harmonic Superimposed DC Voltage on Electrical Tree Characteristics in XLPE
    Zhu, Lewei
    Li, HongNa
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2021, 31 (08)
  • [18] Influence of partial air pressure on the growth characteristics of electrical tree in XLPE cable
    Zhou, Lijun
    Cheng, Rui
    Jiang, Junfei
    Peng, Qian
    Wang, Dongyang
    Zeng, Yuantao
    Gaodianya Jishu/High Voltage Engineering, 2015, 41 (08): : 2650 - 2656
  • [19] Partial discharge in a cylindrical cavity in XLPE under DC voltage: Simulation and experiment
    Gu, Xiao
    Xu, Yang
    Yan, Youxiang
    Zhao, Peng
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2019, 26 (06) : 1831 - 1839
  • [20] Electrical Tree and Partial Discharge Characteristics of Silicone Rubber Under Mechanical Pressure
    Su, Jingang
    Zhang, Peng
    Liu, Zhen
    Huang, Xingwang
    Pang, Xianhai
    Zheng, Zeping
    Han, Tao
    ENERGIES, 2024, 17 (22)