A master-slave haptic system for neurosurgery

被引:1
作者
Zanotto, Vanni [1 ]
Boscariol, Paolo [1 ]
Gasparetto, Alessandro [1 ]
Lanzutti, Albano [1 ]
Vidoni, Renato [1 ]
Di Lorenzo, Nicola [2 ]
Gallina, Pasquale [2 ]
Via, Aldo Dalla [3 ]
Rossi, Aldo [3 ]
机构
[1] Univ Udine, DIEGM, I-33100 Udine, Italy
[2] Univ Florence, Dipartimento Neurochirurg, Florence, Italy
[3] Univ Padua, DIMEG, Padua, Italy
关键词
Neurosurgery; haptic systems; minimally-invasive neurosurgery; PRS; DAANS; STEREOTACTIC INTERSTITIAL RADIOSURGERY; X-RAY DEVICE; ROBOT; SURGERY; TUMORS;
D O I
10.1155/2011/819689
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In recent years, new surgical tools have been designed to improve treatment results and lower patient trauma. Nevertheless, the dexterity and accuracy required for the positioning of new tools are often unreachable, if surgeons are not assisted by suitable systems. Significant advantages are derived from the introduction of computer and robot technologies. For that reason, the interaction between robotic systems and surgeons today is producing new interest worldwide both in medical and engineering fields. In particular, medical robotics has found fruitful ground in neurosurgical applications, since the high functional density of the central nervous system requires strict accuracy constraints on tool positioning. As a matter of fact, the major benefits of robots, such as precision, accuracy and repeatability, make them ideal as neurosurgeons' assistants. This paper presents a master-slave haptic robotic system for minimally invasive neurosurgery, which can aid surgeons in performing safer and more accurate stereotactic neurosurgical treatments. The design of the proposed system is based on LANS (Linear Actuator for NeuroSurgery), which has been developed by our Research Group. Experimental test aimed at showing the added value of the DAANS system over its predecessor, the effectiveness of conformational caps and of the added rotational degree of freedom are scheduled for the upcoming months.
引用
收藏
页码:209 / 220
页数:12
相关论文
共 21 条
[1]  
Benabid A L, 1992, Acta Neurochir Suppl (Wien), V54, P93
[2]  
BENABID AL, 1987, APPL NEUROPHYSIOL, V50, P153
[3]   STEREOTAXIC BRAIN SURGERY - INTEGRATED MINERVA SYSTEM MEETS DEMANDING ROBOTIC REQUIREMENTS [J].
BURCKHARDT, CW ;
FLURY, P ;
GLAUSER, D .
IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE, 1995, 14 (03) :314-317
[4]   COMPUTER-ASSISTED AND ROBOT-ASSISTED RESECTION OF THALAMIC ASTROCYTOMAS IN CHILDREN [J].
DRAKE, JM ;
JOY, M ;
GOLDENBERG, A ;
KREINDLER, D .
NEUROSURGERY, 1991, 29 (01) :27-31
[5]  
Faust R.A., 2007, Robotics in Surgery: History, Current and Future Applications
[6]   Stereotactic interstitial radiosurgery with a miniature X-ray device in the minimally invasive treatment of selected tumors in the thalamus and the basal ganglia [J].
Gallina, P ;
Francescon, P ;
Cavedon, C ;
Casamassima, F ;
Mungai, R ;
Perrini, P ;
Russo, S ;
Di Lorenzo, N .
STEREOTACTIC AND FUNCTIONAL NEUROSURGERY, 2002, 79 (3-4) :202-213
[7]   Stereotactic interstitial radiosurgery and intraoperative radiotherapy with a miniature x-ray device in the treatment of selected brain tumors - Preliminary results [J].
Gallina, P ;
Francescon, P ;
Cavedon, C ;
Casamassima, F ;
Mungai, R ;
Terrin, G ;
Perrini, P ;
Pallotta, S ;
Capaccioli, L ;
Di Lorenzo, N .
RADIOSURGERY, VOL 4, 2002, 4 :167-178
[8]  
Haidegger Tamas, 2008, 2008 2nd IEEE RAS & EMBS International Conference on Biomedical Robotics and Biomechatronics. BioRob 2008, P836, DOI 10.1109/BIOROB.2008.4762912
[9]  
Haidegger T., 2008, P 14 NORD BALT C BIO
[10]   Micromanipulator system (NeuRobot): clinical application in neurosurgery [J].
Hongo, K ;
Goto, T ;
Kakizawa, Y ;
Koyama, J ;
Kawai, T ;
Kan, K ;
Tanaka, Y ;
Kobayashi, S .
CARS 2003: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2003, 1256 :509-513