A Usability Study of 3 Radiotherapy Systems: A Comparative Evaluation Based on Expert Evaluation and User Experience

被引:5
作者
Jiang, Mingyin [1 ,2 ]
Liu, Shenglin [1 ,2 ]
Gao, Jiaqi [1 ,2 ]
Feng, Qingmin [1 ,2 ]
Zhang, Qiang [1 ,2 ]
机构
[1] Huazhong Univ Sci & Technol, Tongji Med Coll, Union Hosp, Dept Med Engn, Wuhan, Hubei, Peoples R China
[2] Huazhong Univ Sci & Technol, Tongji Med Coll, Union Hosp, Healthcare Ergon Lab, Wuhan, Hubei, Peoples R China
来源
MEDICAL SCIENCE MONITOR | 2019年 / 25卷
基金
国家重点研发计划;
关键词
Equipment Design; Equipment Failure Analysis; Equipment Safety; Radiotherapy; User-Computer Interface; QUALITY-ASSURANCE; PATIENT-SAFETY; HEURISTICS; DELIVERY; IMPACT; ERROR;
D O I
10.12659/MSM.913160
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Background: The complex user interface design of radiotherapy treatment delivery systems can lead to use error and patient harm. In this study, we present the results of a comparison of 3 radiotherapy treatment delivery systems now used in China. Material/Methods: We conducted a comprehensive usability study of 3 radiotherapy treatment delivery systems. Expert evaluation was performed through heuristic evaluation with 3 human-factors experts and 1 experienced radiation therapist for each system. User experience was assessed through perceived system usability and workload, using the National Aeronautics and Space Administration Task Load Index and the Post-Study System Usability Questionnaire. Results: For the expert evaluation, 47 usability problems were identified for Varian Trilogy, 75 for Elekta Precise, and 37 for Shinva XHA600E. Most problems were classified as major and minor usability problems, and were found in the process of patient setup and setup verification. For the user experience, radiation therapists presented a lower workload for Varian Trilogy compared to Elekta Precise (P<0.01) and Shinva XHA600E (P<0.01), and a lower workload for Elekta Precise compared to Shinva XHA600E (P=0.020). Radiation therapists perceived a higher system usability for Varian Trilogy compared to Shinva XHA600E (P<0.01), and a higher system usability for Elekta Precise compared to Shinva XHA600E (P<0.01). Conclusions: This research provides valuable data on how 3 radiotherapy treatment delivery systems compare. The results of this study may be useful for hospital equipment procurement decisions, and designing next-generation products to improve patient safety.
引用
收藏
页码:578 / 589
页数:12
相关论文
共 35 条
[1]  
[Anonymous], BOOK EVALUATION EXPE
[2]  
[Anonymous], OBSERVING NURSE INTE
[3]   The Importance of an Ergonomic Workstation to Practicing Sonographers [J].
Baker, Joan P. ;
Coffin, Carolyn T. .
JOURNAL OF ULTRASOUND IN MEDICINE, 2013, 32 (08) :1363-1375
[4]   Applying usability heuristics to radiotherapy systems [J].
Chan, Alvita J. ;
Islam, Mohammad K. ;
Rosewall, Tara ;
Jaffray, David A. ;
Easty, Anthony C. ;
Cafazzo, Joseph A. .
RADIOTHERAPY AND ONCOLOGY, 2012, 102 (01) :142-147
[5]   The use of human factors methods to identify and mitigate safety issues in radiation therapy [J].
Chan, Alvita J. ;
Islam, Mohammad K. ;
Rosewall, Tara ;
Jaffray, David A. ;
Easty, Anthony C. ;
Cafazzo, Joseph A. .
RADIOTHERAPY AND ONCOLOGY, 2010, 97 (03) :596-600
[6]  
Crowley John J., 2002, Journal of Clinical Engineering, V27, P188
[7]   The role of radiotherapy in cancer treatment - Estimating optimal utilization from a review of evidence-based clinical guidelines [J].
Delaney, G ;
Jacob, S ;
Featherstone, C ;
Barton, M .
CANCER, 2005, 104 (06) :1129-1137
[8]   Comparison of elderly people's technique in using two dry powder inhalers to deliver zanamivir: randomised controlled trial [J].
Diggory, P ;
Fernandez, C ;
Humphrey, A ;
Jones, V ;
Murphy, M .
BRITISH MEDICAL JOURNAL, 2001, 322 (7286) :577-579
[9]   A Vibro-Tactile Display for Clinical Monitoring: Real-Time Evaluation [J].
Dosani, Maryam ;
Hunc, Kate ;
Dumont, Guy A. ;
Dunsmuir, Dustin ;
Barralon, Pierre ;
Schwarz, Stephan K. W. ;
Lim, Joanne ;
Ansermino, J. Mark .
ANESTHESIA AND ANALGESIA, 2012, 115 (03) :588-594
[10]   MULTIPLE COMPARISONS USING RANK SUMS [J].
DUNN, OJ .
TECHNOMETRICS, 1964, 6 (03) :241-&