A Vector Flow Imaging Method for Portable Ultrasound Using Synthetic Aperture Sequential Beamforming

被引:16
|
作者
Di Ianni, Tommaso [1 ]
Hoyos, Carlos Armando Villagomez [1 ]
Ewertsen, Caroline [2 ]
Kjeldsen, Thomas Kim [3 ]
Mosegaard, Jesper [3 ]
Nielsen, Michael Bachmann [2 ]
Jensen, Jorgen Arendt [1 ]
机构
[1] Tech Univ Denmark, Ctr Fast Ultrasound Imaging, Dept Elect Engn, DK-2800 Lyngby, Denmark
[2] Copenhagen Univ Hosp, Rigshosp, Dept Radiol, DK-2100 Copenhagen, Denmark
[3] Alexandra Inst, Visual Comp Lab, DK-8200 Aarhus, Denmark
关键词
Portable ultrasound; synthetic aperture (SA); transverse oscillation (TO); vector flow imaging (VFI); VELOCITY ESTIMATION; BLOOD-FLOW; TRANSVERSE OSCILLATION; DOPPLER; AUTOCORRELATION; VELOCIMETRY; SYSTEM;
D O I
10.1109/TUFFC.2017.2742599
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
This paper presents a vector flow imaging method for the integration of quantitative blood flow imaging in portable ultrasound systems. The method combines directional transverse oscillation (TO) and synthetic aperture sequential beamforming to yield continuous velocity estimation in the whole imaging region. Six focused emissions are used to create a high-resolution image (HRI), and a dual-stage beamforming approach is used to lower the data throughput between the probe and the processing unit. The transmit/receive focal points are laterally separated to obtain a TO in the HRI that allows for the velocity estimation along the lateral and axial directions using a phase-shift estimator. The performance of the method was investigated with constant flow measurements in a flow rig system using the SARUS scanner and a 4.1-MHz linear array. A sequence was designed with interleaved B-mode and flow emissions to obtain continuous data acquisition. A parametric study was carried out to evaluate the effect of critical parameters. The vessel was placed at depths from 20 to 40 mm, with beam-to-flow angles of 65 degrees, 75 degrees, and 90 degrees. For the lateral velocities at 20 mm, a bias between -5% and -6.2% was obtained, and the standard deviation (SD) was between 6% and 9.6%. The axial bias was lower than 1% with an SD around 2%. The mean estimated angles were 66.70 degrees +/- 2.86 degrees, 72.65 degrees +/- 2.48 degrees, and 89.13 degrees +/- 0.79 degrees for the three cases. A proof-of-concept demonstration of the real-time processing and wireless transmission was tested in a commercial tablet obtaining a frame rate of 27 frames/s and a data rate of 14 MB/s. An in vivo measurement of a common carotid artery of a healthy volunteer was finally performed to show the potential of the method in a realistic setting. The relative SD averaged over a cardiac cycle was 4.33%.
引用
收藏
页码:1655 / 1665
页数:11
相关论文
共 50 条
  • [41] Adaptive Multi-Lag for Synthetic Aperture Vector Flow Imaging
    Hoyos, Carlos A. Villagomez
    Stuart, Matthias Bo
    Jensen, Jorgen Arendt
    2014 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2014, : 1722 - 1725
  • [42] An optimization method for ultrasonic beamforming with a synthetic aperture
    Matani, A
    Chihara, K
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1998, 37 (5B): : 3013 - 3017
  • [43] Synthetic Transmit Aperture in Ultrasound Imaging
    Trots, Ihor
    Nowicki, Andrzej
    Lewandowski, Marcin
    ARCHIVES OF ACOUSTICS, 2009, 34 (04) : 685 - 695
  • [44] Synthetic Aperture Imaging in Ultrasound Calibration
    Ameri, Golafsoun
    Baxter, John S. H.
    McLeod, A. Jonathan
    Jayaranthe, Uditha
    Chen, Elvis C. S.
    Peters, Terry M.
    MEDICAL IMAGING 2014: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2014, 9036
  • [45] 3D Synthetic Aperture Imaging Method in Spectrum Domain for Low-Cost Portable Ultrasound Systems
    Tasinkiewicz, Jurij
    ARCHIVES OF ACOUSTICS, 2023, 48 (04) : 559 - 572
  • [46] High-resolution synthetic aperture ultrasound imaging with minimum variance beamforming and spiking deconvolution
    Shin, Junseob
    Huang, Lianjie
    MEDICAL IMAGING 2016: ULTRASONIC IMAGING AND TOMOGRAPHY, 2016, 9790
  • [47] An ultrasound beamforming method using 1.5-bit ADCs for portable ultrasound scanners
    Kim, JJ
    Song, TK
    2004 IEEE Ultrasonics Symposium, Vols 1-3, 2004, : 1722 - 1724
  • [48] In vivo color flow mapping using synthetic aperture dual stage beamforming
    Li, Ye
    Hansen, Peter Moller
    Hemmsen, Martin Christian
    Nielsen, Michael Bachmann
    Jensen, Jorgen Arendt
    2012 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2012, : 1592 - 1595
  • [49] Front-End Architecture Design for Low-Complexity 3-D Ultrasound Imaging Based on Synthetic Aperture Sequential Beamforming
    Zhou, Jian
    Mandal, Sumit K.
    West, Brendan L.
    Wei, Siyuan
    Ogras, Umit Y.
    Kripfgans, Oliver D.
    Fowlkes, J. Brian
    Wenisch, Thomas F.
    Chakrabarti, Chaitali
    IEEE TRANSACTIONS ON VERY LARGE SCALE INTEGRATION (VLSI) SYSTEMS, 2021, 29 (02) : 333 - 346
  • [50] High-Volume-Rate 3-D Ultrasound Imaging Based on Synthetic Aperture Sequential Beamforming With Chirp-Coded Excitation
    Zhou, Jian
    Wei, Siyuan
    Jintamethasawat, Rungroj
    Sampson, Richard
    Kripfgans, Oliver D.
    Fowlkes, J. Brian
    Wenisch, Thomas F.
    Chakrabarti, Chaitali
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2018, 65 (08) : 1346 - 1358