A Vector Flow Imaging Method for Portable Ultrasound Using Synthetic Aperture Sequential Beamforming

被引:16
|
作者
Di Ianni, Tommaso [1 ]
Hoyos, Carlos Armando Villagomez [1 ]
Ewertsen, Caroline [2 ]
Kjeldsen, Thomas Kim [3 ]
Mosegaard, Jesper [3 ]
Nielsen, Michael Bachmann [2 ]
Jensen, Jorgen Arendt [1 ]
机构
[1] Tech Univ Denmark, Ctr Fast Ultrasound Imaging, Dept Elect Engn, DK-2800 Lyngby, Denmark
[2] Copenhagen Univ Hosp, Rigshosp, Dept Radiol, DK-2100 Copenhagen, Denmark
[3] Alexandra Inst, Visual Comp Lab, DK-8200 Aarhus, Denmark
关键词
Portable ultrasound; synthetic aperture (SA); transverse oscillation (TO); vector flow imaging (VFI); VELOCITY ESTIMATION; BLOOD-FLOW; TRANSVERSE OSCILLATION; DOPPLER; AUTOCORRELATION; VELOCIMETRY; SYSTEM;
D O I
10.1109/TUFFC.2017.2742599
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
This paper presents a vector flow imaging method for the integration of quantitative blood flow imaging in portable ultrasound systems. The method combines directional transverse oscillation (TO) and synthetic aperture sequential beamforming to yield continuous velocity estimation in the whole imaging region. Six focused emissions are used to create a high-resolution image (HRI), and a dual-stage beamforming approach is used to lower the data throughput between the probe and the processing unit. The transmit/receive focal points are laterally separated to obtain a TO in the HRI that allows for the velocity estimation along the lateral and axial directions using a phase-shift estimator. The performance of the method was investigated with constant flow measurements in a flow rig system using the SARUS scanner and a 4.1-MHz linear array. A sequence was designed with interleaved B-mode and flow emissions to obtain continuous data acquisition. A parametric study was carried out to evaluate the effect of critical parameters. The vessel was placed at depths from 20 to 40 mm, with beam-to-flow angles of 65 degrees, 75 degrees, and 90 degrees. For the lateral velocities at 20 mm, a bias between -5% and -6.2% was obtained, and the standard deviation (SD) was between 6% and 9.6%. The axial bias was lower than 1% with an SD around 2%. The mean estimated angles were 66.70 degrees +/- 2.86 degrees, 72.65 degrees +/- 2.48 degrees, and 89.13 degrees +/- 0.79 degrees for the three cases. A proof-of-concept demonstration of the real-time processing and wireless transmission was tested in a commercial tablet obtaining a frame rate of 27 frames/s and a data rate of 14 MB/s. An in vivo measurement of a common carotid artery of a healthy volunteer was finally performed to show the potential of the method in a realistic setting. The relative SD averaged over a cardiac cycle was 4.33%.
引用
收藏
页码:1655 / 1665
页数:11
相关论文
共 50 条
  • [21] Improving beamforming performance by phased synthetic aperture imaging in medical ultrasound
    Masume Sadeghi
    Ali Mahloojifar
    Journal of Medical Ultrasonics, 2017, 44 : 51 - 62
  • [22] IN VIVO EVALUATION OF SYNTHETIC APERTURE SEQUENTIAL BEAMFORMING
    Hemmsen, Martin Christian
    Hansen, Peter Moller
    Lange, Theis
    Hansen, Jens Munk
    Hansen, Kristoffer Lindskov
    Nielsen, Michael Bachmann
    Jensen, Jorgen Arendt
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2012, 38 (04): : 708 - 716
  • [23] Clinical evaluation of synthetic aperture sequential beamforming
    Hansen, Peter Moller
    Hemmsen, Martin Christian
    Lange, Theis
    Hansen, Jens Munk
    Nielsen, Michael Bachmann
    Jensen, Jorgen Arendt
    MEDICAL IMAGING 2012: ULTRASONIC IMAGING, TOMOGRAPHY, AND THERAPY, 2012, 8320
  • [24] Synthetic Aperture Ultrasound imaging using GPUs
    Iriarte, Juan Manuel
    Cosarinsky, Guillermo
    Brizuela, Jose
    IEEE CACIDI 2016 - IEEE CONFERENCE ON COMPUTER SCIENCES, 2016,
  • [25] Quadrature Synthetic Aperture Beamforming Front-End for Miniaturized Ultrasound Imaging
    Peyton, Graham
    Farzaneh, Behzad
    Soleimani, Hamid
    Boutelle, Martyn G.
    Drakakis, Emmanuel M.
    IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2018, 12 (04) : 871 - 883
  • [26] Compound imaging using Synthetic Aperture Sequential Beamformation
    Jensen, Casper Bo
    Jensen, Jonas
    Hemmsen, Martin Christian
    Hansen, Jens Munk
    Jensen, Jorgen Arendt
    2011 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2011, : 2277 - 2280
  • [27] Real-time 3-D ultrasound imaging using sparse synthetic aperture beamforming
    Lockwood, GR
    Talman, JR
    Brunke, SS
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1998, 45 (04) : 980 - 988
  • [28] A Deep Learning Approach to Synthetic Aperture Vector Flow Imaging
    Stanziola, Antonio
    Robins, Thomas
    Riemer, Kai
    Tang, Meng-Xing
    2018 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2018,
  • [29] Increasing the Dynamic Range of Synthetic Aperture Vector Flow Imaging
    Hoyos, Carlos Villagomez
    Stuart, Matthias Bo
    Jensen, Jorgen Arendt
    MEDICAL IMAGING 2014: ULTRASONIC IMAGING AND TOMOGRAPHY, 2014, 9040
  • [30] Effects influencing focusing in synthetic aperture vector flow imaging
    Oddershede, Niels
    Jensen, Jorgen Arendt
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2007, 54 (09) : 1811 - 1825