Real-Time Tomography System at ISTTOK

被引:8
作者
Carvalho, Pedro [1 ]
Duarte, Paulo [1 ]
Pereira, Tiago [1 ]
Coelho, Rui [1 ]
Silva, Carlos [1 ]
Fernandes, Horacio [1 ]
机构
[1] Assoc Euratom IST, Inst Super Tecn, Inst Plasmas & Fus Nucl Lab Associado, P-1049001 Lisbon, Portugal
关键词
ATCA; ISTTOK; tomography; RADIOLOGICAL APPLICATIONS; LINE INTEGRALS; REPRESENTATION; TOKAMAK;
D O I
10.1109/TNS.2011.2152853
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A real-time plasma position control system is mandatory to achieve long duration (up to 250 ms), Alternating Current (AC) discharges on the ISTTOK tokamak. Such a system has been used for some time supported only on magnetic field diagnostic data. However, this system is clearly challenged when the plasma current is low, rendering it inoperative during the plasma current reversal. A tomography diagnostic with 3 pinhole cameras and 8 silicon photodiode channels per camera was installed and customized to supply alternative plasma position to be used for plasma position control. As no filtering is applied most of the radiation detected is in the visible/near-UV range. The data acquisition and control system is based on a 2MSPS, 32 channel acquisition ATCA module and the data processing is performed on a GPU that is connected to another ATCA module via the PCI-Express port for fast data access. Control commands are relayed to the plasma positioning PF power supplies via optical serial ports. In this work, an overview of some of the tomographic reconstruction algorithms most commonly used for tokamak plasmas is done and an assessment is made on the best candidate for the proposed real-time implementation. The tomography acquisition and plasma control systems operating at ISTTOK are also described. This system aims at achieving the following goals: (i) execute a tomographic reconstruction; (ii) determine the average emissivity position from it; (iii) calculate the shift from the axis and (iv) supply the vertical field power supply with the desired current value, all in less than 100 mu s. The horizontal magnetic field power supply unit, essential for vertical plasma positioning, is foreseen to be integrated in the system and will have no impact in the processing time.
引用
收藏
页码:1427 / 1432
页数:6
相关论文
共 11 条
[1]   X-ray tomography on the TCV tokamak [J].
Anton, M ;
Weisen, H ;
Dutch, MJ ;
vonderLinden, W ;
Buhlmann, F ;
Chavan, R ;
Marletaz, B ;
Marmillod, P ;
Paris, P .
PLASMA PHYSICS AND CONTROLLED FUSION, 1996, 38 (11) :1849-1878
[2]   ATCA digital controller hardware for vertical stabilization of plasmas in tokamaks [J].
Batista, A. J. N. ;
Sousa, J. ;
Varandas, C. A. F. .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2006, 77 (10)
[3]   ISTTOK plasma control with the tomography diagnostic [J].
Carvalho, P. J. ;
Thomsen, H. ;
Coelho, R. ;
Duarte, P. ;
Silva, C. ;
Fernandes, H. .
FUSION ENGINEERING AND DESIGN, 2010, 85 (02) :266-271
[6]   Maximum entropy based reconstruction of soft X ray emissivity profiles in W7-AS [J].
Ertl, K ;
VonderLinden, W ;
Dose, V ;
Weller, A .
NUCLEAR FUSION, 1996, 36 (11) :1477-1488
[7]   Linux real-time framework for fusion devices [J].
Neto, Andre ;
Sartori, Filippo ;
Piccolo, Fabio ;
Barbalace, Antonio ;
Vitelli, Riccardo ;
Fernandes, Horacio .
FUSION ENGINEERING AND DESIGN, 2009, 84 (7-11) :1408-1411
[8]   Fast feedback control for plasma positioning with a PCI hybrid DSP/FPGA board [J].
Valcarcel, D. F. ;
Carvalho, I. S. ;
Carvalho, B. B. ;
Fernandes, H. ;
Sousa, J. ;
Varandas, C. A. F. .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (03) :838-844
[9]   Engineering aspects of the tokamak ISTTOK [J].
Varandas, CAF ;
Cabral, JAC ;
Mendonca, JT ;
Alonso, MP ;
Amorim, P ;
Carvalho, BB ;
Correia, C ;
Cupido, L ;
Carvalho, ML ;
Dias, JM ;
Fernandes, H ;
Freitas, CJ ;
Magalhaes, S ;
Malaquias, A ;
Manso, ME ;
Praxedes, A ;
Santana, J ;
Serra, F ;
Silva, A ;
Soares, A ;
Sousa, J ;
vanToledo, W ;
Vaessen, P ;
Varela, P ;
Vergamota, S ;
deGroot, B .
FUSION TECHNOLOGY, 1996, 29 (01) :105-115
[10]   AN ANALYTICAL EXPRESSION FOR THE RADON-TRANSFORM OF BESSEL BASIS FUNCTION IN TOMOGRAPHY [J].
WANG, L ;
GRANETZ, RS .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1991, 62 (04) :1115-1116