Characterization of a fibre optic swept laser source at 1 μm for optical coherence tomography imaging systems

被引:3
作者
Trifanov, Irina [1 ]
Neagu, Liviu [2 ]
Bradu, Adrian [2 ]
Ribeiro, Antonio Lobo [3 ]
Podoleanu, Adrian Gh. [2 ]
机构
[1] Multiwave Photon SAR Eng, Frederico Ulrich 2650, P-4470605 Moreira Da Maia, Portugal
[2] Univ Kent, Sch Phys Sci, Appl Opt Grp, Canterbury CT2 7NH, Kent, England
[3] Univ Fernando Pessoa, Fac Hlth Sci, Oporto 4200150, Portugal
来源
OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XV | 2011年 / 7889卷
基金
英国工程与自然科学研究理事会; 欧洲研究理事会;
关键词
optical coherence tomography; swept source; SOA; Fabry-Perot filter;
D O I
10.1117/12.874771
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We report the development of a swept wavelength laser at 1 micron based on a linear cavity fibre configuration with an intra-cavity half symmetrical confocal Fabry-Perot tunable filter and a semiconductor optical amplifier as a gain medium. The performances of the source in terms of parameters like: sweep repetition rate (1-20 kHz), center wavelength (1065 nm), wavelength scanning range (max. 50nm), instantaneous line-width (<0.1nm) and a boosted output power of around 40 mW are demonstrated. The new source tested on an OCT system is exhibiting sufficient linearity in wave-number (k-space) at 1 kHz repetition rate; therefore no k-trigger, or wavelength rescaling process was needed.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Depth encoded three-beam swept source Doppler optical coherence tomography
    Wartak, Andreas
    Haindl, Richard
    Trasischker, Wolfgang
    Baumann, Bernhard
    Pircher, Michael
    Hitzenberger, Christoph K.
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XX, 2016, 9697
  • [42] Swept-source optical coherence tomography objective composite activity score for uveitis
    Llorenc, Victor
    Serrano, Alba R.
    Mesquida, Marina
    Lin, Phoebe
    Esquinas, Cristina
    Sainz-de-la-Maza, Maite
    Metea, Christina
    Bosch, Anna
    Calvo, Maria
    Balter, Ariel
    Nakamura, Yukiko
    Molins, Blanca
    Alba, Carmen
    Suhler, Eric
    Adan, Alfredo
    ACTA OPHTHALMOLOGICA, 2021, 99 (07) : 756 - 764
  • [43] All ceramic "table tops" analyzed using swept source optical coherence tomography
    Stoica, Eniko Tunde
    Marcauteanu, Corina
    Sinescu, Cosmin
    Negrutiu, Meda Lavinia
    Topala, Florin
    Duma, Virgil-Florin
    Bradu, Adrian
    Podoleanu, Adrian Gh.
    HIGH-END MEDICINE BASED ON LASER AND BIOTECHNOLOGIES, 2016, 9670
  • [44] Wavenumber calibration and phase measurement in swept source optical coherence tomography
    Shangguan Zi-Wei
    Shen Yi
    Li Peng
    Ding Zhi-Hua
    ACTA PHYSICA SINICA, 2016, 65 (03)
  • [45] Assessing Embryo Development using Swept Source Optical Coherence Tomography
    Caujolle, S.
    Cernat, R.
    Silvestri, G.
    Marques, M. J.
    Bradu, A.
    Feuchter, T.
    Robinson, G.
    Griffin, D.
    Podoleanu, A.
    2ND CANTERBURY CONFERENCE ON OCT WITH EMPHASIS ON BROADBAND OPTICAL SOURCES, 2018, 10591
  • [46] Phase calculation with a swept source in optical coherence tomography: Jitter influence
    Munoz Moreno, Gilberto
    Alcala Ochoa, Noe
    OPTICS AND LASERS IN ENGINEERING, 2011, 49 (06) : 663 - 667
  • [47] Thickness Measurement Opaque Material by Swept Source Optical Coherence Tomography
    Wu, Qian
    Dai, Jianing
    Zhu, Jie
    Wang, Xiwen
    Chen, Xinjian
    Mo, Jianhua
    OPTICAL METROLOGY AND INSPECTION FOR INDUSTRIAL APPLICATIONS VI, 2019, 11189
  • [48] Self-Assembled Quantum Dot Based Swept Laser Source for Optical Coherence Tomography Applications
    Peyvast, N.
    Childs, D. T. D.
    Krstajic, N.
    Lu, Z.
    Matcher, S. J.
    Livshits, D.
    Shkolnik, A.
    Krestnikov, I.
    Hogg, R. A.
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XVI, 2012, 8213
  • [49] Classification of human gingival sulcus using swept-source optical coherence tomography: In vivo imaging
    Lee, Jaeyul
    Park, Jaeseok
    Shirazi, Muhammad Faizan
    Jo, Hosung
    Kim, Pilun
    Wijesinghe, Ruchire Eranga
    Jeon, Mansik
    Kim, Jeehyun
    INFRARED PHYSICS & TECHNOLOGY, 2019, 98 : 155 - 160
  • [50] Office-based laryngeal imaging in awake patients with swept-source optical coherence tomography
    Yu, Lingfeng
    Liu, Gangjun
    Guo, Shuguang
    Wong, Brian J. F.
    Chen, Zhongping
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XIII, 2009, 7168