Optical Coherence Tomography Protocols for Screening of Hydroxychloroquine Retinopathy in Asian Patients

被引:31
作者
Ahn, Seong Joon [1 ]
Joung, Jooyoung [1 ]
Lim, Han Woong [1 ]
Lee, Byung Ro [1 ]
机构
[1] Hanyang Univ, Hanyang Univ Hosp, Coll Med, Dept Ophthalmol, 17 Haengdang Dong, Seoul 133792, South Korea
关键词
RECOMMENDATIONS; CHLOROQUINE; PROGRESSION; TOXICITY; THERAPY;
D O I
10.1016/j.ajo.2017.09.025
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To investigate the distribution of outer retinal changes in hydroxychloroquine (HCQ) retinopathy and explore optical coherence tomography (OCT) protocols to maximize the sensitivity of HCQ retinopathy detection in Asian patients. DESIGN: Diagnostic validity assessment. METHODS: SETTING: Institutional. PATIENT POPULATION: Forty-eight eyes (24 patients) with HCQ retinopathy underwent 6-mm horizontal and vertical line scans and 6 X 6-mm(2) volume scans using spectral-domain OCT (SD-OCT), and 9-mm line scans and 6 x 6-mm(2) and 12 x 9-mm(2) volume scans using swept-source OCT (SS-OCT). OBSERVATION PROCEDURES: Distances from the fovea to the defective photoreceptors were measured in the temporal, nasal, superior, and inferior directions from line scan OCT images. The sensitivity of retinopathy detection, indicated by photoreceptor defects, was compared among protocols. MAIN OUTCOME MEASURES: Detection of photoreceptor defects and distances from the fovea to the defects. RESULTS: The average minimum distance from the fovea to an area of photoreceptor defects was 1.84 +/- 1.26 mm (mean standard deviation). The distances were greater than 3 mm horizontally and vertically in 15 (31.3%) and 17 (35.4%) eyes with HCQ retinopathy, respectively, and only wide-field line or volume scans could detect defects in the eyes. The 9-mm line scans detected HCQ retinopathy significantly better than 6-mm scans (P < .001); the sensitivity of the wide volume scan was significantly greater than the standard volume scan (P = .001). The 12 x 9-mm(2) volume scan detected retinopathy with the greatest sensitivity (100%). CONCLUSIONS: Our study recommends a wide-field OCT scan to screen Asian patients taking HCQ medications. ((C) 2017 Elsevier Inc. All rights reserved.)
引用
收藏
页码:11 / 18
页数:8
相关论文
共 12 条
[1]   Hydroxychloroquine Screening Practice Patterns Within a Large Multispecialty Ophthalmic Practice [J].
Au, Adrian ;
Parikh, Vishal ;
Modi, Yasha S. ;
Ehlers, Justis P. ;
Schachat, Andrew P. ;
Singh, Rishi P. .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2015, 160 (03) :561-568
[2]  
Browning DJ, 2014, HYDROXYCHLOROQUINE C, P265
[3]   GENTAMICIN THERAPY [J].
DEVINE, BJ .
DRUG INTELLIGENCE & CLINICAL PHARMACY, 1974, 8 (11) :650-655
[4]   Pericentral Hydroxychloroquine Retinopathy in Korean Patients [J].
Lee, Dong Hoon ;
Melles, Ronald B. ;
Joe, Soo Geun ;
Lee, Joo Yong ;
Kim, June-Gone ;
Lee, Chang-Keun ;
Yoo, Bin ;
Koo, Bon San ;
Kim, Jee Taek ;
Marmor, Michael F. ;
Yoon, Young Hee .
OPHTHALMOLOGY, 2015, 122 (06) :1252-1256
[5]   Recommendations on screening for chloroquine and hydroxychloroquine retinopathy - A report by the American Academy of Ophthalmology [J].
Marmor, MF ;
Carr, RE ;
Easterbrook, M ;
Farjo, AA ;
Mieler, WF .
OPHTHALMOLOGY, 2002, 109 (07) :1377-1382
[6]   Recommendations on Screening for Chloroquine and Hydroxychloroquine Retinopathy (2016 Revision) [J].
Marmor, Michael F. ;
Kellner, Ulrich ;
Lai, Timothy Y. Y. ;
Melles, Ronald B. ;
Mieler, William F. .
OPHTHALMOLOGY, 2016, 123 (06) :1386-1394
[7]   Effect of Disease Stage on Progression of Hydroxychloroquine Retinopathy [J].
Marmor, Michael F. ;
Hu, Julia .
JAMA OPHTHALMOLOGY, 2014, 132 (09) :1105-1112
[8]   Disparity between Visual Fields and Optical Coherence Tomography in Hydroxychloroquine Retinopathy [J].
Marmor, Michael F. ;
Melles, Ronald B. .
OPHTHALMOLOGY, 2014, 121 (06) :1257-1262
[9]   Comparison of Screening Procedures in Hydroxychloroquine Toxicity [J].
Marmor, Michael F. .
ARCHIVES OF OPHTHALMOLOGY, 2012, 130 (04) :461-469
[10]   Revised Recommendations on Screening for Chloroquine and Hydroxychloroquine Retinopathy [J].
Marmor, Michael F. ;
Kellner, Ulrich ;
Lai, Timothy Y. Y. ;
Lyons, Jonathan S. ;
Mieler, William F. .
OPHTHALMOLOGY, 2011, 118 (02) :415-422