One-step direct immunoassay with horseradish peroxidase as antigen for studying the functionality of antibody surfaces

被引:6
|
作者
Coussot, G. [1 ]
Faye, C. [2 ]
Le Postollec, A. [3 ]
Dobrijevic, M. [3 ]
机构
[1] Univ Montpellier, CNRS, IBMM, ENSCM, F-34093 Montpellier 5, France
[2] COLCOM, Cap Alpha, F-34830 Clapiers, France
[3] Univ Bordeaux, CNRS, Labe Astrophys Bordeaux, B18N,Allee Geoffroy St Hilaire, F-33615 Pessac, France
关键词
Affinity binding; HRP; Direct ELISA; Immunoassay; Anti-HRP antibody surface; WASTE-WATER; IMMOBILIZATION; REMOVAL; BIOSENSOR; PHENYLENEDIAMINE; PERFORMANCE; PHOSPHATE;
D O I
10.1016/j.talanta.2017.10.032
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Antibody-coated surfaces (Ab surfaces) play a key role in bioanalytical tools developed for biosensors and diagnostics. Therefore, a high and well-defined functional activity of the Ab surface is required. The functional activity of the Ab surface depends on its available binding sites i.e. "the active sites" that are able to capture antigen (Ag). The number of active binding sites strongly depends on the immobilization strategy used to fix the Ab on the solid surface. Determination of layer thickness or surface topology are often used to characterize the Ab surfaces but there is no gold standard method for the study of the functionality of the Ab surfaces. For that purpose, we aim at developing an assay allowing to determine the performances of Ab surfaces. In the present study, anti-horseradish peroxidase antibody (anti-HRP Ab) is used as capture Ab covalently bound to the surface and enzyme HRP as Ag. This direct assay permits, in one-step, to generate a signal utilizing the catalytic properties of HRP. The signal is directly proportional to the amount of HRP bound on the Ab surface, and therefore to the active binding sites of immobilized Ab. The HRP/anti-HRP Ab interactions may be a useful indicator to construct accurate and reproducible active Ab surfaces and also to improve their performances in term of stability and sensitivity. Optimization of the assay parameters and quality of the results are presented. A good repeatability and an acceptable inter-day precision (RSD < 10%) are reported.
引用
收藏
页码:922 / 927
页数:6
相关论文
共 50 条
  • [1] A One-Step Immunoassay for Carbohydrate Antigen 19-9 by Biosensor Based on Imaging Ellipsometry
    Huang, Chenghong
    Chen, Yanyan
    Jin, Gang
    ANNALS OF BIOMEDICAL ENGINEERING, 2011, 39 (01) : 185 - 192
  • [2] Electrochemical sandwich immunoassay for the prostate specific antigen using a polyclonal antibody conjugated to thionine and horseradish peroxidase
    Biniaz, Zahra
    Mostafavi, Ali
    Shamspur, Tayebeh
    Torkzadeh-Mahani, Masoud
    Mohamadi, Maryam
    MICROCHIMICA ACTA, 2017, 184 (08) : 2731 - 2738
  • [3] Electrochemical sandwich immunoassay for the prostate specific antigen using a polyclonal antibody conjugated to thionine and horseradish peroxidase
    Zahra Biniaz
    Ali Mostafavi
    Tayebeh Shamspur
    Masoud Torkzadeh-Mahani
    Maryam Mohamadi
    Microchimica Acta, 2017, 184 : 2731 - 2738
  • [4] A One-Step Immunoassay for Carbohydrate Antigen 19-9 by Biosensor Based on Imaging Ellipsometry
    Chenghong Huang
    Yanyan Chen
    Gang Jin
    Annals of Biomedical Engineering, 2011, 39 : 185 - 192
  • [5] One-step construction of biosensor based on chitosan-ionic liquid-horseradish peroxidase biocomposite formed by electrodeposition
    Xi, Fengna
    Liu, Lijun
    Wu, Qi
    Lin, Xianfu
    BIOSENSORS & BIOELECTRONICS, 2008, 24 (01) : 29 - 34
  • [6] One-step construction of reagentless biosensor based on chitosan-carbon nanotubes-nile blue-horseradish peroxidase biocomposite formed by electrodeposition
    Xi, Fengna
    Liu, Lijun
    Chen, Zhichun
    Lin, Xianfu
    TALANTA, 2009, 78 (03) : 1077 - 1082
  • [7] High throughput determination of BTEX by a one-step fluorescence polarization immunoassay
    Eremin, SA
    Knopp, D
    Niessner, R
    Hong, JY
    Park, SJ
    Choi, MJ
    ENVIRONMENTAL CHEMISTRY, 2005, 2 (03) : 227 - 234
  • [8] Site-specific conjugation of an antibody on a gold nanoparticle surface for one-step diagnosis of prostate specific antigen with dynamic light scattering
    Mustafaoglu, Nur
    Kiziltepe, Tanyel
    Bilgicer, Basar
    NANOSCALE, 2017, 9 (25) : 8684 - 8694
  • [9] Luminol, horseradish peroxidase and antibody ternary codified gold nanoparticles for a label-free homogenous chemiluminescent immunoassay
    Li, Fang
    Zhang, Yufei
    Liu, Jiachang
    He, Jianbo
    ANALYTICAL METHODS, 2018, 10 (07) : 722 - 729
  • [10] A simple, rapid one-step ELISA using antibody-antibody complex
    Jiang, Wenwen
    Liu, Xiaoli
    Wu, Di
    Wang, Hongwei
    Wang, Yanwei
    Chen, Hong
    Yuan, Lin
    BIOTECHNOLOGY AND APPLIED BIOCHEMISTRY, 2015, 62 (01) : 126 - 131