32-Channel RF Coil Optimized for Brain and Cervical Spinal Cord at 3 T

被引:39
作者
Cohen-Adad, J. [1 ,2 ]
Mareyam, A. [1 ]
Keil, B. [1 ,2 ]
Polimeni, J. R. [1 ,2 ]
Wald, L. L. [1 ,2 ,3 ]
机构
[1] Massachusetts Gen Hosp, Dept Radiol, AA Martinos Ctr Biomed Imaging, Charlestown, MA 02129 USA
[2] Harvard Univ, Sch Med, Boston, MA USA
[3] MIT, Harvard MIT Div Hlth Sci & Technol, Cambridge, MA 02139 USA
关键词
RF coil; phased-array; brain; spinal cord; PHASED-ARRAY; PHYSIOLOGICAL NOISE; HEAD COIL; IN-VIVO; MRI; TESLA; UNCERTAINTY; ECHO; FMRI;
D O I
10.1002/mrm.22906
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Diffusion and functional magnetic resonance imaging of the spinal cord remain challenging due to the small cross-sectional size of the cord and susceptibility-related distortions. Although partially addressable through parallel imaging, few highly parallel array coils have been implemented for the cervical cord. Here, we developed a 32-channel coil that fully covers the brain and c-spine and characterized its performance in comparison with a commercially available head/neck/spine array. Image and temporal signal-to-noise ratio were, respectively, increased by 2x and 1.8x in the cervical cord. Averaged g-factors at 4x acceleration were lowered by 22% in the brain and by 39% in the spinal cord, enabling 1-mm isotropic R = 4 multi-echo magnetization prepared gradient echo of the full brain and c-spine in 3:20 min. Diffusion imaging of the cord at 0.6 x 0.6 x 5 mm(3) resolution and tractography of the full brain and c-spine at 1.7-mm isotropic resolution were feasible without noticeable distortion. Improvements of this nature potentially enhance numerous basic and clinical research studies focused on spinal and supraspinal regions. Magn Reson Med 66:1198-1208, 2011. (C) 2011 Wiley-Liss, Inc.
引用
收藏
页码:1198 / 1208
页数:11
相关论文
共 45 条
[11]   Issues about the fMRI of the human spinal cord [J].
Giove, F ;
Garreffa, G ;
Giulietti, G ;
Mangia, S ;
Colonnese, C ;
Maraviglia, B .
MAGNETIC RESONANCE IMAGING, 2004, 22 (10) :1505-1516
[12]   Diffusion Spectrum Imaging Shows the Structural Basis of Functional Cerebellar Circuits in the Human Cerebellum In Vivo [J].
Granziera, Cristina ;
Schmahmann, Jeremy Dan ;
Hadjikhani, Nouchine ;
Meyer, Heiko ;
Meuli, Reto ;
Wedeen, Van ;
Krueger, Gunnar .
PLOS ONE, 2009, 4 (04)
[13]   Generalized Autocalibrating Partially Parallel Acquisitions (GRAPPA) [J].
Griswold, MA ;
Jakob, PM ;
Heidemann, RM ;
Nittka, M ;
Jellus, V ;
Wang, JM ;
Kiefer, B ;
Haase, A .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (06) :1202-1210
[14]  
HARDY CJ, 2007, P 15 ANN M ISMRM BER, P244
[15]   A brief review of parallel magnetic resonance imaging [J].
Heidemann, RM ;
Özsarlak, Ö ;
Parizel, PM ;
Michiels, J ;
Kiefer, B ;
Jellus, V ;
Müller, M ;
Breuer, F ;
Blaimer, M ;
Griswold, MA ;
Jakob, PM .
EUROPEAN RADIOLOGY, 2003, 13 (10) :2323-2337
[16]  
Held P, 2003, J NEURORADIOLOGY, V30, P83
[17]   Improved optimization for the robust and accurate linear registration and motion correction of brain images [J].
Jenkinson, M ;
Bannister, P ;
Brady, M ;
Smith, S .
NEUROIMAGE, 2002, 17 (02) :825-841
[18]   Determining and visualizing uncertainty in estimates of fiber orientation from diffusion tensor MRI [J].
Jones, DK .
MAGNETIC RESONANCE IN MEDICINE, 2003, 49 (01) :7-12
[19]   Image reconstruction in SNR units: A general method for SNR measurement [J].
Kellman, P ;
McVeigh, ER .
MAGNETIC RESONANCE IN MEDICINE, 2005, 54 (06) :1439-1447
[20]   Physiological noise in oxygenation-sensitive magnetic resonance imaging [J].
Krüger, G ;
Glover, GH .
MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (04) :631-637